A psychoacoustic test for diagnosing hyperacusis based on ratings of natural sounds
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Hyperacusis is defined as an increased sensitivity to sounds, i.e. sounds presented at moderate levels can produce discomfort or even pain. Existing diagnostic methods, like the Hyperacusis Questionnaire (HQ) and Loudness Discomfort Levels (LDLs), have been challenged because of their variability and lack of agreement on appropriate cut-off values. We propose a novel approach by using psychoacoustic ratings of natural sounds as an assessment tool for hyperacusis. Subjects (n = 81) were presented with natural and artificial (tone pips, noises) sounds (n = 69) in a controlled environment at four sound levels (60, 70, 80 and 90 dB SPL). The task was to rate them on a pleasant to unpleasant visual analog scale. The inherent challenge of this study was to create a new diagnostic tool when no gold standard of hyperacusis diagnosis exists. We labeled our subjects as hyperacusic (n = 26) when they were diagnosed as such by at least two of three methods (HQ, LDLs and self-report). There was a significant difference between controls (n = 23) and hyperacusics in the median global rating of pleasant sounds. Median global ratings of unpleasant sounds and artificial sounds did not differ significantly. Then we selected the subset of sounds that could best discriminate the controls from the hyperacusics, the Core Discriminant Sounds (CDS), and we used them to develop a new metric: The CDS score. A normalized global score and a score for each sound level can be computed with respect to a control population without hyperacusis. A receiver operating characteristic analysis showed that the accuracy of our method in distinguishing subjects with and without complaints of hyperacusis (86%, 95% Confidence Interval (CI): 76-93%) is comparable to that of existing methods such as the LDL (77%, CI: 67-86%) and the HQ (80%, CI: 69-88%). We believe that the CDS score is more relevant to subject's complaints than LDLs and that it could be applied in a clinical environment in a fast and effective way, while minimizing discomfort and biases.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The ratings on the hyperacusis test confirmed its presence (Enzler et al., 2021) (Supplementary Figure 2).”
From Exploring the middle ear function in patients with a cluster of symptoms including tinnitus, hyperacusis, ear fullness and/or pain (2022) · cites this paper as Enzler et al., 2021
In the citing paper
“Hyperacusis was diagnosed using a newly validated test developed at the lab and described in a previous study (Enzler, Fournier, and Noreña 2021).”
From Exploring the middle ear function in patients with a cluster of symptoms including tinnitus, hyperacusis, ear fullness and/or pain (2022) · cites this paper as Enzler, Fournier, and Noreña 2021
Citations
Cites
Statistical Power Analysis for the Behavioral Sciences
Muller, K. (1989) · Technometrics · doi:10.1080/00401706.1989.10488618 · Cited by 99,167
Kleiner, M., Brainard, D. H., & Pelli, D. G. (2007) · MPG.PuRe (Max Planck Society) · Cited by 6,195
Effect size estimates: Current use, calculations, and interpretation.
Fritz, C. O., Morris, P. E., & Richler, J. J. (2012) · Journal of Experimental Psychology: General · doi:10.1037/a0024338 · Cited by 5,199
Two-sided confidence intervals for the single proportion: comparison of seven methods
Newcombe, R. G. (1998) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19980430)17:8<857::aid-sim777>3.0.co;2-e · Cited by 5,107
NEURO-OTOLOGICAL MANIFESTATIONS OF MIGRAINE
KAYAN, A., & HOOD, J. D. (1984) · Brain · doi:10.1093/brain/107.4.1123 · Cited by 533
Psychometric Normalization of a Hyperacusis Questionnaire
Khalfa, S., Dubal, S., Veuillet, E., Perez-Diaz, F., Jouvent, R., & Collet, L. (2002) · ORL · doi:10.1159/000067570 · Cited by 488
Misophonia: Physiological investigations and case descriptions
Edelstein, M., Brang, D., Rouw, R., & Ramachandran, V. S. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00296 · Cited by 330
A review of hyperacusis and future directions: Part I. Definitions and manifestations
Tyler, R. S., Pienkowski, M., Roncancio, E. R., Jun, H. J., Brozoski, T., Dauman, N., Coelho, C. B., Andersson, G., Keiner, A. J., Cacace, A. T., et al. (2014) · American Journal of Audiology · doi:10.1044/2014_aja-14-0010 · Cited by 329
Hypersensitivity to sound: Questionnaire data, audiometry and classification
Anari, M., Axelsson, A., Eliasson, A., & Magnusson, L. (1999) · Scandinavian Audiology · doi:10.1080/010503999424653 · Cited by 271
Increased perception of loudness in autism
Khalfa, S., Bruneau, N., Rogé, B., Georgieff, N., Veuillet, E., Adrien, J.-L., Barthélémy, C., & Collet, L. (2004) · Hearing Research · doi:10.1016/j.heares.2004.07.006 · Cited by 268
Research works printed but not linked: 1
- Delacour, 2005, La Courbe ROC (receiver operating characteristic) : principes et principales applications en biologie clinique, Ann Biol Clin, 63, 11
Cited by
Simoes, J. P., Daoud, E., Shabbir, M., Amanat, S., Assouly, K. K. S., Biswas, R., Casolani, C., Dode, A., Enzler, F., Jacquemin, L., et al. (2021) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2021.647285 · Cited by 58
Self-citationA psychoacoustic test for misophonia assessment
Enzler, F., Loriot, C., Fournier, P., & Noreña, A. J. (2021) · Scientific Reports · doi:10.1038/s41598-021-90355-8 · Cited by 54
Self-citationAazh, H., Erfanian, M., Danesh, A. A., & Moore, B. C. J. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.900065 · Cited by 53
Aazh, H., Hayes, C., Moore, B. C. J., Danesh, A. A., & Vitoratou, S. (2022) · Journal of the American Academy of Audiology · doi:10.1055/a-1780-4002 · Cited by 50
Hyperacusis: Loudness intolerance, fear, annoyance and pain
Salvi, R., Chen, G., & Manohar, S. (2022) · Hearing Research · doi:10.1016/j.heares.2022.108648 · Cited by 42
Metadata
- Authors
- Enzler, F., Fournier, P., & Noreña, A. J.
- Venue
- Hearing Research
- Publisher
- Elsevier BV
- Published
- 2021-02
- Volume
- 400
- Pages
- 108124
- ISSN
- 0378-5955 (ISSN-L)
- OpenAlex
- W3109228822
- Cited by
- 51
- References
- 43
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- bronze
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- www.elsevier.com/open-access/userlicense/1.0/ (am, 315 d)
- Funders
- Horizon 2020
- European Research Council (764604)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.