Does periprocedural anticoagulation management of atrial fibrillation affect the prevalence of silent thromboembolic lesion detected by diffusion cerebral magnetic resonance imaging in patients undergoing radiofrequency atrial fibrillation ablation with open irrigated catheters? Results from a prospective multicenter study
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Silent cerebral ischemia (SCI) has been reported in 14% of cases after catheter ablation of atrial fibrillation (AF) with radiofrequency (RF) energy and discontinuation of warfarin before AF ablation procedures. OBJECTIVE: The purpose of this study was to determine whether periprocedural anticoagulation management affects the incidence of SCI after RF ablation using an open irrigated catheter. METHODS: Consecutive patients undergoing RF ablation for AF without warfarin discontinuation and receiving heparin bolus before transseptal catheterization (group I, n = 146) were compared with a group of patients who had protocol deviation in terms of maintaining the therapeutic preprocedural international normalized ratio (patients with subtherapeutic INR) and/or failure to receive pretransseptal heparin bolus infusion and/or ≥2 consecutive ACT measurements <300 seconds (noncompliant population, group II, n = 134) and with a group of patients undergoing RF ablation with warfarin discontinuation bridged with low molecular weight heparin (group III, n = 148). All patients underwent preablation and postablation (within 48 hours) diffusion magnetic resonance imaging. RESULTS: SCI was detected in 2% of patients (3/146) in group I, 7% (10/134) in group II, and 14% (21/148) in group III (P <.001). "Therapeutic INR" was strongly associated with a lower prevalence of postprocedural silent cerebral ischemia (SCI). Multivariable analysis demonstrated nonparoxysmal AF (odds ratio 3.8, 95% confidence interval 1.5-9.7, P = .005) and noncompliance to protocol (odds ratio 2.8, 95% confidence interval 1.5-5.1, P <.001] to be significant predictors of ischemic events. CONCLUSION: Strict adherence to an anticoagulation protocol significantly reduces the prevalence of SCI after catheter ablation of AF with RF energy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atrial fibrillation as an independent risk factor for stroke: the Framingham study
Wolf, P. A., Abbott, R. D., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.8.983 · Cited by 7,388 · cited 2×
“These protocols contained (1) T1 sagittal, (2) DWI axial, (3) flair axial, (4) T2 axial, (5) T1 axial, (6) T2* coronal, and (7) GRE-EPI coronal images as needed to delineate acute lesions within 48 hours compared to preablation scans.”
Go, A. S., Hylek, E. M., Phillips, K. A., Chang, Y., Henault, L. E., Selby, J. V., & Singer, D. E. (2001) · JAMA · doi:10.1001/jama.285.18.2370 · Cited by 6,205
Impact of Atrial Fibrillation on the Risk of Death: The Framingham Heart Study
Benjamin, E. J., Wolf, P. A., D’Agostino, R. B., Silbershatz, H., Kannel, W. B., & Levy, D. (1998) · Circulation · doi:10.1161/01.cir.98.10.946 · Cited by 4,575
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852
Calkins, H., Reynolds, M. R., Spector, P., Sondhi, M., Xu, Y., Martin, A., Williams, C. J., & Sledge, I. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.824789 · Cited by 847 · cited 2×
“These protocols contained (1) T1 sagittal, (2) DWI axial, (3) flair axial, (4) T2 axial, (5) T1 axial, (6) T2* coronal, and (7) GRE-EPI coronal images as needed to delineate acute lesions within 48 hours compared to preablation scans.”
Cited by
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
Tzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Sepehri Shamloo, A., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Europace · doi:10.1093/europace/euae043 · Cited by 634
Self-citationDi Biase, L., Burkhardt, J. D., Mohanty, P., Mohanty, S., Sanchez, J. E., Trivedi, C., Güneş, M., Gökoğlan, Y., Gianni, C., Horton, R. P., et al. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.07.770 · Cited by 445
Self-citationTzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Shamloo, A. S., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.03.017 · Cited by 298
Self-citationSticherling, C., Marin, F., Birnie, D., Boriani, G., Calkins, H., Dan, G.-A., Gulizia, M., Halvorsen, S., Hindricks, G., Kuck, K.-H., et al. (2015) · EP Europace · doi:10.1093/europace/euv190 · Cited by 197
“18 For those patients treated with a VKA or a NOAC, the recommendation is to have at least 3 weeks of effective stable international normalized ratio (INR) at therapeutic levels (between 2 and 3 for VKA).(19) – 23 Patients on a VKA should aim for an average therapeutic target range (TTR) of .”
BackgroundInfluentialSilent cerebral events/lesions related to atrial fibrillation ablation: a clinical review
DENEKE, T., JAIS, P., SCAGLIONE, M., SCHMITT, R., DI BIASE, L., CHRISTOPOULOS, G., SCHADE, A., MÜGGE, A., BANSMANN, M., NENTWICH, K., et al. (2015) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12608 · Cited by 170
Self-citationDi Biase, L., Lakkireddy, D., Trivedi, C., Deneke, T., Martinek, M., Mohanty, S., Mohanty, P., Prakash, S., Bai, R., Reddy, M., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.02.028 · Cited by 158
Self-citation
Metadata
- Authors
- Di Biase, L., Gaita, F., Toso, E., Santangeli, P., Mohanty, P., Rutledge, N., Yan, X., Mohanty, S., Trivedi, C., Bai, R., Price, J., Horton, R., Gallinghouse, G. J., Beheiry, S., Zagrodzky, J., Canby, R., Leclercq, J. F., Halimi, F., Scaglione, M., Cesarani, F., Faletti, R., Sanchez, J., Burkhardt, J. D., & Natale, A.
- Venue
- Heart Rhythm
- Publisher
- Elsevier BV
- Published
- 2014-05
- Volume
- 11
- Issue
- 5
- Pages
- 791-798
- ISSN
- 1547-5271 (ISSN-L)
- OpenAlex
- W1994028806
- Cited by
- 130
- References
- 5
- FWCI
- 12.21
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.