Assessing the accuracy of an automated atrial fibrillation detection algorithm using smartphone technology: The iREAD Study
Abstract
Background The Kardia Mobile Cardiac Monitor (KMCM) detects atrial fibrillation (AF) via a handheld cardiac rhythm recorder and AF detection algorithm. The algorithm operates within predefined parameters to provide a "normal" or "possible atrial fibrillation detected" interpretation; outside of these parameters, an "unclassified" rhythm is reported. The system has been increasingly used, but its performance has not been independently tested.Objective The objective of this study was to evaluate whether the KMCM system can accurately detect AF.Methods A single-center, adjudicator-blinded case series of 52 consecutive patients with AF admitted for antiarrhythmic drug initiation were enrolled. Serial 12-lead electrocardiograms (ECGs) and nearly simultaneously acquired KMCM recordings were obtained.Results There were 225 nearly simultaneously acquired KMCM and ECG recordings across 52 enrolled patients (mean age 68 years; 67% male). After exclusion of unclassified recordings, the KMCM automated algorithm interpretation had 96.6% sensitivity and 94.1% specificity for AF detection as compared with physician-interpreted ECGs, with a κ coefficient of 0.89. Physician-interpreted KMCM recordings had 100% sensitivity and 89.2% specificity for AF detection as compared with physician-interpreted ECGs, with a κ coefficient of 0.85. Sixty-two recordings (27.6%) were unclassified by the KMCM algorithm. In these instances, physician interpretation of KMCM recordings had 100% sensitivity and 79.5% specificity for AF detection as compared with 12-lead ECG interpretation, with a κ coefficient of 0.71.Conclusion The KMCM system provides sensitive and specific AF detection relative to 12-lead ECGs when an automated interpretation is provided. Direct physician review of KMCM recordings can enhance diagnostic yield, especially for unclassified recordings.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the automatic diagnostic algorithm has excellent sensitivity (96.6%) and specificity (94%) for correctly interpreting AF versus normal sinus rhythm [15].”
From Multi-centre Randomised Controlled Trial of a Smartphone-based Event Recorder Alongside Standard Care Versus Standard Care for Patients Presenting to the Emergency Department with Palpitations and Pre-syncope: The IPED (Investigation of Palpitations in the ED) study (2019) · cites this paper as [15]
Citations
Cites
2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H. G., Cigarroa, J. E., Cleveland, J. C., CONTI, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,145
Heart Disease and Stroke Statistics—2015 Update: A Report From the American Heart Association
Mozaffarian, D., Benjamin, E. J., Go, A. S., Arnett, D. K., Blaha, M. J., Cushman, M., de Ferranti, S., Després, J.-P., Fullerton, H. J., Howard, V. J., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000152 · Cited by 5,797
Worldwide Epidemiology of Atrial Fibrillation: A Global Burden of Disease 2010 Study
Chugh, S. S., Havmoeller, R., Narayanan, K., Singh, D., Rienstra, M., Benjamin, E. J., Gillum, R. F., Kim, Y.-H., McAnulty, J. H., Zheng, Z.-J., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005119 · Cited by 4,506
Calkins, H. G., Hindricks, G., Cappato, R., Kim, Y., Saad, E., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, A. J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,794
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000040 · Cited by 2,056
Colilla, S., Crow, A., Petkun, W., Singer, D. E., Simon, T. A., & Liu, X. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.05.063 · Cited by 1,323
Wearable Devices as Facilitators, Not Drivers, of Health Behavior Change
Patel, M. S., Asch, D. A., & Volpp, K. G. (2015) · JAMA · doi:10.1001/jama.2014.14781 · Cited by 808
Halcox, J. P. J., Wareham, K., Cardew, A., Gilmore, M., Barry, J. P., Phillips, C., & Gravenor, M. B. (2017) · Circulation · doi:10.1161/circulationaha.117.030583 · Cited by 580
Lowres, N., Neubeck, L., Salkeld, G., Krass, I., McLachlan, A. J., Redfern, J., Bennett, A. A., Briffa, T., Bauman, A., Martinez, C., et al. (2014) · Thrombosis and Haemostasis · doi:10.1160/th14-03-0231 · Cited by 458
Lau, J. K., Lowres, N., Neubeck, L., Brieger, D. B., Sy, R. W., Galloway, C. D., Albert, D. E., & Freedman, S. B. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.01.220 · Cited by 326
Powell, A. C., Landman, A., & Bates, D. W. (2014) · JAMA · doi:10.1001/jama.2014.2564 · Cited by 236
Tarakji, K. G., Wazni, O. M., Callahan, T. D., Kanj, M. H., Hakim, A. H., Wolski, K., Wilkoff, B. L., Saliba, W. I., & Lindsay, B. D. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.11.015 · Cited by 138
The Outlook of Digital Health for Cardiovascular Medicine
Turakhia, M. P., Desai, S. A., & Harrington, R. A. (2016) · JAMA Cardiology · doi:10.1001/jamacardio.2016.2661 · Cited by 56
Flagged first, then by citations
1 of the 14 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström‐Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 10,550
Smartwatch Performance for the Detection and Quantification of Atrial Fibrillation
Wasserlauf, J., You, C., Patel, R., Valys, A., Albert, D., & Passman, R. (2019) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.118.006834 · Cited by 245
How useful is the smartwatch ECG?
Isakadze, N., & Martin, S. S. (2019) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2019.10.010 · Cited by 234
Clinical Validation of 5 Direct-to-Consumer Wearable Smart Devices to Detect Atrial Fibrillation
Mannhart, D., Lischer, M., Knecht, S., du Fay de Lavallaz, J., Strebel, I., Serban, T., Vögeli, D., Schaer, B., Osswald, S., Mueller, C., et al. (2023) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2022.09.011 · Cited by 175
Windows into human health through wearables data analytics
Witt, D. R., Kellogg, R., Snyder, M. P., & Dunn, J. (2019) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2019.01.001 · Cited by 165
Metadata
- Authors
- William, A. D., Kanbour, M., Callahan, T., Bhargava, M., Varma, N., Rickard, J., Saliba, W., Wolski, K., Hussein, A., Lindsay, B. D., Wazni, O. M., & Tarakji, K. G.
- Affiliations
- Cleveland Clinic (US)
- Marshall University (US)
- Corresponding author
- Tarakji, Khaldoun G.
- ORCID
- Venue
- Heart Rhythm
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 15
- Issue
- 10
- Pages
- 1561-1565
- ISSN
- 1547-5271 (ISSN-L)
- OpenAlex
- W2888509599
- Cited by
- 154
- References
- 14
- Citations by year
- 2026: 5 · 2025: 7 · 2024: 10 · 2023: 32 · 2022: 19 · 2021: 30 · 2020: 25 · 2019: 23 · 2018: 2
- FWCI
- 15.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Heart Rhythm (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- atrial fibrillation, diagnostic accuracy, sensitivity and specificity, 12-lead ECG
- MeSH terms
- Smartphone, Adult, Aged, Aged, 80 and over, Algorithms, Atrial Fibrillation, Electrocardiography, Female, Heart Conduction System, Humans, Male, Middle Aged, Predictive Value of Tests, Signal Processing, Computer-Assisted, Telemetry, Reproducibility of Results, Single-Blind Method, Mobile Applications
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review