CoChat

Electrophysiology studies for predicting atrioventricular block in patients with syncope: A systematic review and meta-analysis

Sheldon, Robert S., Lei, Lucy Y., Solbiati, Monica, Chew, Derek S., Raj, Satish R., Costantino, Giorgio, Morillo, Carlos, Sandhu, Roopinder K. · 2021 · Heart Rhythm
Cited by 20

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

BACKGROUND Syncope may be caused by intermittent complete heart block in patients with bundle branch block. Electrophysiologic studies (EPS) testing for infraHisian heart block is recommended by the ESC syncope guidelines, based on decades-old estimates of their negative predictive values (NPV) for complete heart block. OBJECTIVE The aim was to determine the NPV of EPS for complete heart block in syncope patients with bundle branch block. METHODS We searched MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, and CINAHL without language restriction from database inception to October 2019 for Medical Subject Headings terms and keywords related to "syncope", "heart block", and "programmed electrical stimulation". A random effects meta-analysis was conducted with a primary outcome of the proportion of patients with negative EPS who later presented with complete heart block, diagnosed with surface ECG recordings versus continuous implantable cardiac monitoring (ICM). RESULTS Ten reports contained 12 cohorts with 639 patients who met inclusion criteria. The mean age was 69±7 years with 35±10% women, and 85% of patients had bifascicular block. 7 cohorts recorded clinical outcomes with external ECG recordings and 5 cohorts featured ICMs. The mean prespecified HV interval criterion was >70 ms. In studies with surface ECG recordings there were 7% (CI 7%, 17%) patients who developed complete heart block compared to 29% (CI 24%, 35%) in the ICM studies (p=0.0001). CONCLUSION The NPV of EPS in syncope patients with bundle branch block is 0.71, sufficiently low to question its use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.hrthm.2021.04.010

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 13

  1. Englund, 1995, Disopyramide stress test: a sensitive and specific tool for predicting impending high degree atrioventricular block in patients with bifascicular block, Br Heart J, 74, 650, 10.1136/hrt.74.6.650 · DOI
  2. Twidale, 1988, Clinical implications of electrophysiology study findings in patients with chronic bifascicular block and syncope, Aust N Z J Med, 18, 841, 10.1111/j.1445-5994.1988.tb01641.x · DOI · Paper page
  3. Petrac, 1996, Prospective evaluation of infrahisal second-degree AV block induced by atrial pacing in the presence of chronic bundle branch block and syncope, Pacing Clin Electrophysiol, 19, 784, 10.1111/j.1540-8159.1996.tb03360.x · DOI · Paper page
  4. Kaul, 1988, Evaluation of patients with bundle branch block and “unexplained” syncope: a study based on comprehensive electrophysiologic testing and ajmaline stress, Pacing Clin Electrophysiol, 11, 289, 10.1111/j.1540-8159.1988.tb05006.x · DOI · Paper page
  5. Dini, 1978, Significato pronostico dell’intervallo H-V in 66 pazienti con blocco di branca cronico, G Ital Cardiol, 8, 392
  6. Azocar, 2011, Syncope and bundle branch block: diagnostic yield of a stepped use of electrophysiology study and implantable loop recorders, Rev Esp Cardiol, 64, 213, 10.1016/j.recesp.2010.10.016 · DOI
  7. Boulé, 2014, Predictors of advanced His-Purkinje conduction disturbances in patients with unexplained syncope and bundle branch block, Can J Cardiol, 30, 606
  8. Stroup, 2000, Meta-analysis Of Observational Studies in Epidemiology (MOOSE) group. Meta-analysis of observational studies in epidemiology: a proposal for reporting, J Am Med Assoc, 283, 2008, 10.1001/jama.283.15.2008 · DOI · Paper page
  9. Leduc, 2018, The safety and efficacy of on-site paramedic and allied health treatment interventions targeting the reduction of emergency department visits by long-term care patients: systematic review protocol, Syst Rev, 7, 206, 10.1186/s13643-018-0868-5 · DOI
  10. Krahn, 2012, Empiric pacemaker compared with a monitoring strategy in patients with syncope and bifascicular conduction block—rationale and design of the Syncope: Pacing or Recording in ThE Later Years (SPRITELY) study, Europace, 14, 1044, 10.1093/europace/eus005 · DOI · Paper page
  11. Pournazari, 2017, Diagnostic value of neurological studies in diagnosing syncope: a systematic review, Can J Cardiol, 33, 1604
  12. Oqab, 2018, What is the impact of frailty on prescription of anticoagulation in elderly patients with atrial fibrillation? A systematic review and meta-analysis, J Atr Fibrillation, 10, 1870, 10.4022/jafib.1870 · DOI
  13. Jorge JG, Raj SR, Teixeira PS, Teixeira JAC, Sheldon RS. Likelihood of injury due to vasovagal syncope: a systematic review and meta-analysis [published online ahead of print March 8, 2021]. Europace. https://doi.org/10.1093/europace/euab041. · DOI

Cited by

See all 20

Metadata

Authors
Sheldon, R. S., Lei, L. Y., Solbiati, M., Chew, D. S., Raj, S. R., Costantino, G., Morillo, C., & Sandhu, R. K.
Venue
Heart Rhythm
Publisher
Elsevier BV
Published
2021-08
Volume
18
Issue
8
Pages
1310-1317
ISSN
1547-5271 (ISSN-L)
OpenAlex
W3155971928
Cited by
20
References
7
FWCI
1.04
Type
journal article
Language
en
Open access
closed
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.