Potential tissue damage from transcutaneous recharge of neuromodulation implants
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This process, observed in systems like Medtronic Restore and ANS Eon, can significantly raise localized tissue temperature (Lovik et al., 2009).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Lovik et al., 2009
In the citing paper
“Recharging neural implants via an external skin-mounted antenna can increase temperature, by creating eddy currents and Ohmic heat within the implant.”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Lovik et al., 2009
Citations
Cites
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.1.5 · Cited by 3,982
Henriques, F. C., & Moritz, A. R. (1947) · PubMed Central · Cited by 721
Physical properties of tissue: F. A. Duck Harcourt Brace Jovanovich Ltd, London; 1990, 346 pp.
Bowker, P. (1991) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(91)90034-5 · Cited by 608
Radiofrequency Energy-Induced Heating During MR Procedures: A Review
Shellock, F. G. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<30::aid-jmri4>3.0.co;2-s · Cited by 343
On the heating of linear conductive structures as guide wires and catheters in interventional MRI
Nitz, W. R., Oppelt, A., Renz, W., Manke, C., Lenhart, M., & Link, J. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200101)13:1<105::aid-jmri1016>3.0.co;2-0 · Cited by 321
Effects of magnetic resonance imaging on cardiac pacemakers and electrodes
Achenbach, S. S., Moshage, W. E. L., Diem, B., Bieberlea, T., Schibgilla, V., & Bachmann, K. F. (1997) · American Heart Journal · doi:10.1016/s0002-8703(97)70083-8 · Cited by 254
Effects of thermal properties and geometrical dimensions on skin burn injuries
Jiang, S. C., Ma, N., Li, H., & Zhang, X. X. (2002) · Burns · doi:10.1016/s0305-4179(02)00104-3 · Cited by 247
Park, S., Kamondetdacha, R., & Nyenhuis, J. A. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21159 · Cited by 232
Investigation of the factors responsible for burns during MRI
Dempsey, M. F., Condon, B. R., & Hadley, D. M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1088 · Cited by 232
MRI and implanted medical devices: basic interactions with an emphasis on heating
Nyenhuis, J. A., Park, S.-M., Kamondetdacha, R., Amjad, A., Shellock, F. G., & Rezai, A. R. (2005) · IEEE Transactions on Device and Materials Reliability · doi:10.1109/tdmr.2005.859033 · Cited by 199
A new technique for monitoring the deep body temperature in man from the intact skin surface.
Fox, R. H., & Solman, A. (1971) · PubMed · Cited by 179
MEASUREMENT OF THE THERMAL PROPERTIES OF HUMAN SKIN. A REVIEW
Cohen, M. L. (1977) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12507965 · Cited by 179
A New Method for Monitoring Deep Body Temperature from the Skin Surface
Fox, R. H., Solman, A. J., Isaacs, R., Fry, A. J., & MacDonald, I. C. (1973) · Clinical Science · doi:10.1042/cs0440081 · Cited by 168
Regulation of the cutaneous circulation.
Johnson, J. M., Brengelmann, G. L., Hales, J. R. S., Vanhoutte, P., & Wenger, C. B. (1986) · PubMed · Cited by 160
Interference in Implanted Cardiac Devices, Part II
Pinski, S. L., & Trohman, R. G. (2002) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2002.01496.x · Cited by 132
Electromagnetic interference in patients with implanted pacemakers or cardioverter-defibrillators
NIEHAUS, M., & Tebbenjohanns, J. (2001) · Heart · doi:10.1136/heart.86.3.246 · Cited by 115
Interference in implanted cardiac devices--Part II.
Irnich, W. E. (2003) · PubMed · Cited by 114
MATHEMATICAL MODEL OF SKIN EXPOSED TO THERMAL RADIATION
Weaver, J. A., & Stoll, A. M. (1967) · doi:10.21236/ad0659973 · Cited by 98
Numerical Evaluation of Heating of the Human Head Due to Magnetic Resonance Imaging
Nguyen, U. D., Brown, J. S., Chang, I. A., Krycia, J., & Mirotznik, M. S. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827559 · Cited by 76
Bassen, H., Kainz, W., Mendoza, G., & Kellom, T. (2006) · Minimally Invasive Therapy & Allied Technologies · doi:10.1080/13645700600640931 · Cited by 72
Mathematical model of skin exposed to thermal radiation
Weaver, J. A., & Stoll, A. M. (1969) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-196909000-00039 · Cited by 64
Implantable Cardioverter Defibrillator Dysfunction During and After Magnetic Resonance Imaging
Anfinsen, O., Berntsen, R. F., Aass, H., Kongsgaard, E., & Amlie, J. (2002) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2002.01400.x · Cited by 63
Calcagnini, G., Triventi, M., Censi, F., Mattei, E., Bartolini, P., Kainz, W., & Bassen, H. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21536 · Cited by 62
Improvement of deep body thermometer for man
Kobayashi, T., Nemoto, T., Kamiya, A., & Togawa, T. (1975) · Annals of Biomedical Engineering · doi:10.1007/bf02363069 · Cited by 56
Intraoperative diffusion imaging on a 0.5 Tesla interventional scanner
Mamata, Y., Mamata, H., Nabavi, A., Kacher, D. F., Pergolizzi, R. S., Schwartz, R. B., Kikinis, R., Jolesz, F. A., & Maier, S. E. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200101)13:1<142::aid-jmri1022>3.0.co;2-g · Cited by 53
MRI INDUCED HEATING OF DEEP BRAIN STIMULATION LEADS: EFFECT OF THE AIR-TISSUE INTERFACE
Mohsin, S. A., Sheikh, N. M., & Saeed, U. (2008) · Electromagnetic waves · doi:10.2528/pier08040504 · Cited by 52
Heating Near Implanted Medical Devices by the MRI RF-magnetic Field
Nyenhuis, J. A., Kildishev, A. V., Athey, T. W., Bourland, J. D., Foster, K. S., & Graber, G. P. (1999) · IEEE International Magnetics Conference · doi:10.1109/intmag.1999.837338 · Cited by 46
Brajkovic, D., & Ducharme, M. B. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-1336-1 · Cited by 32
Hand, J. W., Lagendijk, J. J. W., Hajnal, J. V., Lau, R. W. M., & YOUNG, I. R. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<186::aid-jmri21>3.0.co;2-2 · Cited by 23
Yassi, K., Ziane, F., Bardinet, E., Moinard, M., Veyret, B., & Chateil, J. (2007) · Journal de Radiologie · doi:10.1016/s0221-0363(07)89813-1 · Cited by 16
Mattei, E., Calcagnini, G., Triventi, M., Censi, F., Bartolini, P., Kainz, W., & Bassen, H. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260068 · Cited by 15
Heat Flow from Rechargeable Neuromodulation Systems into Surrounding Media
Weinmann, J. J., & Sparrow, E. M. (2009) · Neuromodulation Technology at the Neural Interface · doi:10.1111/j.1525-1403.2009.00198.x · Cited by 10
Self-citation
Cited by
Johnson, N., Abraham, J., Helgeson, Z., Minkowycz, W. J., & Sparrow, E. M. (2011) · Journal of Thermal Science and Engineering Applications · doi:10.1115/1.4003610 · Cited by 63
Self-citationEstimating the time and temperature relationship for causation of deep-partial thickness skin burns
Abraham, J., Plourde, B. D., Vallez, L. J., Stark, J. R., & Diller, K. R. (2015) · Burns · doi:10.1016/j.burns.2015.06.002 · Cited by 59
Self-citationRadziemski, L., & Makin, I. R. S. (2016) · Ultrasonics · doi:10.1016/j.ultras.2015.07.012 · Cited by 45
“This temperature excursion is the same as calculated for one of the inductive charging systems now in clinical use [32], while the backplate of the receiver assembly in the present study showed a rise of less than 1.”
Romanelli, P., Piangerelli, M., Ratel, D., Gaude, C., Costecalde, T., Puttilli, C., Picciafuoco, M., Benabid, A. L., & Torres-Martinez, N. (2018) · Journal of neurosurgery · doi:10.3171/2017.10.jns17400 · Cited by 51
Comprehensive method to predict and quantify scald burns from beverage spills
Abraham, J., Nelson-Cheeseman, B. B., Sparrow, E. M., Wentz, J. E., Gorman, J. M., & Wolf, S. E. (2016) · International Journal of Hyperthermia · doi:10.1080/02656736.2016.1211752 · Cited by 29
Self-citation
Metadata
- Authors
- Lovik, R. D., Abraham, J. P., & Sparrow, E. M.
- Affiliations
- University of Minnesota (US)
- University of St. Thomas - Minnesota (US)
- Corresponding author
- Abraham, John P.
- ORCID
- Abraham, John P.
- Venue
- International Journal of Heat and Mass Transfer
- Publisher
- Elsevier BV
- Published
- 2009-07
- Volume
- 52
- Issue
- 15-16
- Pages
- 3518-3524
- ISSN
- 0017-9310 (ISSN-L)
- OpenAlex
- W1985755780
- Cited by
- 29
- References
- 32
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2023: 2 · 2022: 1 · 2021: 1 · 2020: 2 · 2019: 1 · 2018: 5 · 2017: 1 · 2016: 3 · 2015: 4 · 2013: 1
- FWCI
- 1.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- International Journal of Heat and Mass Transfer (publishedVersion)
- Funders
- Medtronic
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
- Keywords
- magnetic induction heating, tissue heating, tissue necrosis, cell damage, bioheat transfer model, temperature distribution, hot spot temperature
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.