A New Method for Monitoring Deep Body Temperature from the Skin Surface
The DOI matches its Crossref record.
Abstract
1. A new technique for monitoring the deep body temperature is described. The technique depends on creating a zone of zero heat-flow across the body shell; this brings the deep body temperature to the skin surface where it is measured with a simple electronic thermometer. 2. The new device gives a temperature closely comparable with other methods for measuring the deep body temperature in the resting subject, and is simple to use and socially acceptable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Temperature Monitoring and Perioperative Thermoregulation
Sessler, D. I., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31817f6d76 · Cited by 758
“An interesting method of measuring core temperature from the surface of the skin is to use a system originally proposed by Fox et al.17,18 and refined by Togawa et al.19 The technique is to combine a heater with a thermal flux transducer (which is, effectively, two thermometers separated by a known thermal insulator).”
MethodHeat Flow and Distribution during Induction of General Anesthesia
Matsukawa, T., Sessler, D. I., Sessler, A. M., Schroeder, M., Ozaki, M., Kurz, A., & Cheng, C. (1995) · Anesthesiology · doi:10.1097/00000542-199503000-00008 · Cited by 528
Considerations for the measurement of core, skin and mean body temperatures
Taylor, N. A. S., Tipton, M. J., & Kenny, G. P. (2014) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2014.10.006 · Cited by 420
Heat Flow and Distribution during Epidural Anesthesia
Matsukawa, T., Sessler, D. I., Christensen, R., Ozaki, M., & Schroeder, M. (1995) · Anesthesiology · doi:10.1097/00000542-199511000-00008 · Cited by 290
Unique Aspects of the Elderly Surgical Population: An Anesthesiologist’s Perspective
Yang, R., Wolfson, M., & Lewis, M. C. (2011) · Geriatric Orthopaedic Surgery & Rehabilitation · doi:10.1177/2151458510394606 · Cited by 166
Metadata
- Authors
- Fox, R. H., Solman, A. J., Isaacs, R., Fry, A. J., & MacDonald, I. C.
- Venue
- Clinical Science
- Publisher
- Portland Press Ltd.
- Published
- 1973-01-01
- Volume
- 44
- Issue
- 1
- Pages
- 81-86
- ISSN
- 0301-0538 (ISSN-L)
- OpenAlex
- W147517017
- Cited by
- 168
- References
- 0
- FWCI
- 1.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A New Method for Monitoring Deep Body Temperature from the Skin Surface. https://app.cochat.ai/papers/10.1042/cs0440081
- The paper
- Fox, R. H., Solman, A. J., Isaacs, R., Fry, A. J., & MacDonald, I. C. (1973). A New Method for Monitoring Deep Body Temperature from the Skin Surface. Clinical Science. https://doi.org/10.1042/cs0440081
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.