The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Frost formation in the cross-flow plate heat exchanger for energy recovery
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Phase transition has a significant impact on heat recovery in a cross-flow plate heat exchanger.
“Moreover, phase transition had a significant impact on heat recovery (Fig. 5).”
Citations
Cites
Review Article: A Critical Review of Properties and Models for Frost Formation Analysis
Iragorry, J., Tao, Y.-X., & Jia, S. (2004) · HVAC&R Research · doi:10.1080/10789669.2004.10391111 · Cited by 89
Flagged first, then by citations
Research works printed but not linked: 30
- Fauchoux, 2007, The effect of energy recovery on perceived air quality, energy consumption and economics of an office building, ASHRAE Trans., 113, 437
- S. Anisimov, A. Jedlikowski, M. Skrzycki, Heat and mass transfer in the cross-flow plate-fin heat exchangers used for energy recovery from exhaust air, in: Proceedings of the Xth International Scientific Conference, Quality of Indoor Air and Environment”, Volgograd-Budapest May 13–20, 2012, pp. 302–308.
- H. Jiang, Development of a simulation and optimization tool for heat exchanger design, Dissertation directed by: Professor Reinhard Radermacher, Department of Mechanical Engineering, accessed August 21, 2013, <http://hdl.handle.net/1903/3676>.
- Liu, 2013, Poly (vinyl chloride)/montmorillonite hybrid membranes for total-heat recovery ventilation, J. Membr. Sci., 443, 83, 10.1016/j.memsci.2013.04.046 · DOI
- Zhang, 2011, One-step fabrication and analysis of an asymmetric cellulose acetate membrane for heat and moisture recovery, J.Membr. Sci., 366, 158, 10.1016/j.memsci.2010.09.054 · DOI
- S. Anisimov, A. Jedlikowski, An influence of surface cross-flow plate–fin heat exchangers on efficiency of heat recovery units used in ventilation and air conditioning systems, in: Proceedings of the XIIth International Scientific Conference ,Quality of Indoor Air and Environment, Volgograd-Haifa, March 23 – April 3 2013, VolGASU 2014 – pp. 141–147.
- Stoitchkov, 1998, Int J. Refrig., 21, 463, 10.1016/S0140-7007(98)00004-8 · DOI
- Mardiana, 2011, An experimental study on the performance of enthalpy recovery system for building, Energy Build., 43, 2533, 10.1016/j.enbuild.2011.06.009 · DOI
- San, 2000, Second-law analysis of a wet crossflow heat exchanger, Energy, 25, 939, 10.1016/S0360-5442(00)00035-9 · DOI
- Nielsen, 2009, Dynamic model of counter flow air to air heat exchanger for comfort ventilation with condensation and frost formation, department of civil engineering, technical university of denmark, brovej, building 118, DK-2800 Kgs. Lyngby, Denmark, Appl. Therm. Eng., 29, 462, 10.1016/j.applthermaleng.2008.03.006 · DOI
- J. Kragh, J. Rose, S. Svendsen, Mechanical ventilation with heat recovery in cold climates, in: Proceedings of the 7th Symposium on Building Physics in the Nordic Countries. Vol. Bind 2 1.ed. Reykjavik: Oddi hf, 2005, accessed March 7, 2014: <http://www.researchgate.net/publication/242412569_Mechanical_ventilation_with_heat_recovery_in_cold_climates/file/60b7d5297b0bfc10f5.pdf>.
- Nasr, 2014, A review of frosting in air-to-air energy exchangers, Renew. Sustainable Energy Rev., 30, 538, 10.1016/j.rser.2013.10.038 · DOI · Paper page
- Jilek, 1993, Exergy efficiency of counterflow air/air heat exchanger with vapour condensation, Wärme-und StoffüBertragung, 28, 123, 10.1007/BF01541108 · DOI
- Terekhov, 1998, Heat and mass transfer in condensation of water vapor from moist air, J. Eng. Phys. Thermophys., 71, 771, 10.1007/BF02681625 · DOI
- Brouwers, 1996, Heat transfer condensation and fog formation in crossflow plastic heat exchangers, Int. J. Heat Mass Transfer, 39, 391, 10.1016/0017-9310(95)00113-N · DOI
- M.R.L Bantle, E.M. Barber, R.W. Besant, A mathematical model of a plate type air-to-air heat exchanger operating under frost forming conditions (M.Sc. thesis). Department of Agricultural Engineering, University of Saskatchewan, 1987.
- M.R.L. Bantle, Frost formation in an air to air heat exchanger (MSc thesis), University of Saskatchewan, 1987.
- Phillips, 1989, A model to compare freezing control strategies for residential air-to-air heat recovery ventilators, ASHRAE Trans., 95, 475
- Holmberg, 1989, Sensible and latent heat transfer in cross-counterflow gas-to-gas heat exchanger, ASME J. Heat Transfer, 111, 173, 10.1115/1.3250640 · DOI
- Holmberg, 1989, Prediction of condensation and frosting limits in rotary wheels for heat recovery in buildings, ASHRAE Trans., 95, 64
- Anisimov, 2015, Theoretical study of the basic cycles for indirect evaporative air cooling, Int. J. Heat Mass Transfer, 84, 974, 10.1016/j.ijheatmasstransfer.2015.01.087 · DOI
- Pandelidis, 2015, Numerical analysis of the heat and mass transfer processes in selected M-Cycle heat exchangers for the dew point evaporative cooling, Energy Convers. Manage., 90, 62, 10.1016/j.enconman.2014.11.008 · DOI
- Mishra, 2006, Transient behaviour of crossflow heat exchangers due to perturbations in temperature and flow, Int. J. Heat Mass Transfer, 49, 1083, 10.1016/j.ijheatmasstransfer.2005.09.003 · DOI
- Mishra, 2008, Effect of temperature and flow nonuniformity on transient behaviour of crossflow heat exchanger, Int. J. Heat Mass Transfer, 51, 2583, 10.1016/j.ijheatmasstransfer.2007.07.054 · DOI
- Zhao, 2008, Comparative study of heat and mass exchanging materials for indirect evaporative cooling systems, Build. Environ., 43, 1902, 10.1016/j.buildenv.2007.11.009 · DOI
- K. Ikeda, Ch. Fujino, Y. Yamauchi, Heat and mass transfer in the nonisothermal fixed bed adsorption column with nonlinear equilibrium, Bulletin of the faculty of engineering, Yokohama National University, Vol. 26, 1977, pp. 117–139.
- A. Jedlikowski, Wymiana ciepła w wymiennikach krzyżowych w systemach wentylacyjnych i klimatyzacyjnych z odzyskiem ciepła z powietrza wywiewanego/Heat transfer in cross-flow heat exchangers for heat recovery from exhaust air in ventilation and air conditioning systems, Praca Doktorska/PhD Dissertation, Promotor/Supervisor: Professor Sergey Anisimov, Politechnika Wrocławska/Wrocław University of Technology, Wydział Inżynierii Środowiska/Department of Environmental Engineering 2012.
- Anisimov, 2014, Numerical analysis of selected evaporative exchangers with the Maisotsenko Cycle, Energy Convers. Manage., 88, 426, 10.1016/j.enconman.2014.08.055 · DOI
- Anisimov, 2014, Numerical study of the Maisotsenko cycle heat and mass exchanger, Int. J. Heat Mass Transfer, 75, 75, 10.1016/j.ijheatmasstransfer.2014.03.050 · DOI
- Anisimov, 2011, Heat and mass transfer processes in indirect evaporative air conditioners through the Maisotsenko cycle, Int. J. Energy Clean Environ., 12, 273, 10.1615/InterJEnerCleanEnv.2012005770 · DOI
Cited by
Sorted by citations
Patil, M. S., Seo, J.-H., & Lee, M.-Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.107 · Cited by 86
Metadata
- Authors
- Anisimov, S., Jedlikowski, A., & Pandelidis, D.
- Affiliations
- Wrocław University of Science and Technology (PL)
- Corresponding author
- Pandelidis, Demis
- Venue
- International Journal of Heat and Mass Transfer
- Publisher
- Elsevier BV
- Published
- 2015-11
- Volume
- 90
- Pages
- 201-217
- ISSN
- 0017-9310 (ISSN-L)
- OpenAlex
- W856885979
- Cited by
- 51
- References
- 1
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 4 · 2023: 3 · 2022: 7 · 2021: 3 · 2020: 6 · 2019: 5 · 2018: 2 · 2017: 8 · 2016: 7 · 2015: 2
- FWCI
- 6.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Heat and Mass Transfer (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- frost formation, energy recovery, coupled heat and mass transfer, ice formation, dew point, relative humidity, temperature effectiveness, safe operating conditions, exhaust air temperature
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review