Saturated pool boiling enhancement using porous lattice structures produced by Selective Laser Melting
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Abstract Pool boiling heat transfer of saturated FC-72 under atmospheric pressure was studied for porous lattice structures fabricated using the Selective Laser Melting (SLM) technique. The substrates possess repeating geometry of octet-truss unit cell and were varied with unit cell sizes of 2.0 mm, 3.0 mm and 5.0 mm and structure heights of 2.5 mm, 5.0 mm and 10.0 mm. In comparison with a plain surface, the porous structures show significant enhancement in nucleate boiling heat transfer coefficients and delay of Critical Heat Flux (CHF). The enhancement is attributed to the increased surface area, increased nucleation site density and capillary-assisted suction of the porous structure. The porous structure allows sustained liquid replenishment which delayed the hydrodynamic choking and CHF significantly. The best performing substrate with the 3-mm unit cell size and 5-mm structure height has an average nucleate boiling heat transfer coefficient of 1.35 W/cm2·K, which is 2.81 times that of the plain surface at 0.48 W/cm2·K. Heat transfer mechanisms are proposed for the different heat flux levels of the porous structures based on visual observations. The boiling patterns are classified as low, mid, high and very-high heat flux levels. At high heat flux level, two separate modes of stable and unstable boiling patterns are observed. For the stable boiling pattern, there are distinct bubble departure and liquid replenishment pathways, thus allowing a good convection flow. However, for the unstable boiling pattern, there is major liquid–vapor counter-flow, which disrupts the orderly liquid replenishment pathway.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Error Analysis
Taylor, J. R. (1982) · Medical Entomology and Zoology · Cited by 2,807
Effective properties of the octet-truss lattice material
Deshpande, V. S., Fleck, N. A., & Ashby, M. F. (2001) · Journal of the Mechanics and Physics of Solids · doi:10.1016/s0022-5096(01)00010-2 · Cited by 1,741 · cited 3×
“Thermophysical properties of FC-72 at 1 atm [34]”
BackgroundInfluentialRead, N., Wang, W., Essa, K., & Attallah, M. M. (2015) · Materials & Design (1980-2015) · doi:10.1016/j.matdes.2014.09.044 · Cited by 1,218
Review on thermal transport in high porosity cellular metal foams with open cells
Zhao, C. Y. (2012) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2012.03.017 · Cited by 566 · cited 4×
“Xu and Zhao [20] investigated the effect of cutting V-shaped grooves on copper foams for pool boiling experiments.”
BackgroundInfluentialEffective Thermal Conductivity and Permeability of Aluminum Foam Materials1
Paek, J. W., Kang, B. H., Kim, S.-Y., & Hyun, J. M. (2000) · International Journal of Thermophysics · doi:10.1023/a:1006643815323 · Cited by 438
Review of boiling heat transfer enhancement on micro/nanostructured surfaces
Kim, D. E., Yu, D. I., Jerng, D. W., Kim, M. H., & Ahn, H. S. (2015) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2015.03.023 · Cited by 355
Chua, C. K., & Leong, K. F. (2014) · WORLD SCIENTIFIC eBooks · doi:10.1142/9008 · Cited by 261
Self-citationPool Boiling Heat Transfer From Plain and Microporous, Square Pin-Finned Surfaces in Saturated FC-72
Rainey, K. N., & You, S. M. (2000) · Journal of Heat Transfer · doi:10.1115/1.1288708 · Cited by 242 · cited 4×
“The Young-Laplace equation for a capillary tube is shown in Eq.”
BackgroundInfluentialSing, S. L., Lam, L. P., Zhang, D. Q., Liu, Z. H., & Chua, C. K. (2015) · Materials Characterization · doi:10.1016/j.matchar.2015.07.007 · Cited by 238
Wong, M., Owen, I., Sutcliffe, C. J., & Puri, A. (2009) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2008.06.002 · Cited by 236 · cited 1×
“[26] produced five heat sinks of various fin geometries using Al6061 material for air convective heat transfer and reported heat transfer enhancement for fins of elliptical and V-shaped geometries.”
MethodPool boiling and flow boiling on micro- and nanostructured surfaces
Shojaeian, M., & Koşar, A. (2015) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2014.12.016 · Cited by 217 · cited 2×
“Shojaeian and Koşar [2] and Kim et al. [3] compiled comprehensive reviews of pool and * Corresponding author.”
A critical review of pool and flow boiling heat transfer of dielectric fluids on enhanced surfaces
Leong, K. C., Ho, J. Y., & Wong, K. K. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.10.138 · Cited by 190 · cited 1×
“[4] conducted a review of pool boiling heat transfer of dielectric fluids on enhanced surfaces.”
BackgroundSelf-citationEnhanced boiling heat transfer from electronic components by use of surface microstructures
Honda, H., & Wei, J. J. (2004) · Experimental Thermal and Fluid Science · doi:10.1016/s0894-1777(03)00035-9 · Cited by 180 · cited 3×
“Surface modification A thorough literature review on the use of surface microstructures for pool boiling enhancement was performed by Honda and Wei [1].”
BackgroundEffect of particle size on surface-coating enhancement of pool boiling heat transfer
Sarangi, S., Weibel, J. A., & Garimella, S. V. (2015) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2014.09.052 · Cited by 163 · cited 1×
“[41] deposited sintered copper particles of about 200 μm on a copper surface and obtained high heat transfer coefficients, but observed a lower CHF of about 10 W/cm2 due to insufficient fluid replenishment.”
BackgroundSaturated pool boiling of FC-72 from enhanced surfaces produced by Selective Laser Melting
Ho, J. Y., Wong, K. K., & Leong, K. C. (2016) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2016.03.073 · Cited by 158 · cited 4×
“[31] employed SLM to investigate pool boiling enhancements using surfaces of micro-fin and micro-cavity geometries.”
BackgroundMethodSelf-citationPool boiling heat transfer on uniform and non-uniform porous coating surfaces
Ji, X., Xu, J., Zhao, Z., & Wolong, Y. (2013) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2013.03.002 · Cited by 134
Convective heat transfer performance of airfoil heat sinks fabricated by selective laser melting
Ho, J. Y., Wong, K. K., Leong, K. C., & Wong, T. N. (2017) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2016.12.016 · Cited by 115 · cited 1×
“[28] produced heat sinks consisting of fins of airfoil cross-sections using AlSi10Mg material.”
MethodSelf-citationEsarte, J., Blanco, J., Bernardini, A., & San-José, J. T. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.09.123 · Cited by 102 · cited 1×
“[32] demonstrated heat pipe wick manufacturing using the SLM technique and conducted a study of the optimized wick design for a two-phase cooling system.”
MethodFabrication of heat sinks by Selective Laser Melting for convective heat transfer applications
Wong, K. K., Ho, J. Y., Leong, K. C., & Wong, T. N. (2016) · Virtual and Physical Prototyping · doi:10.1080/17452759.2016.1211849 · Cited by 81
Self-citationAdditive manufacturing boosts efficiency of heat transfer components
Neugebauer, R., Müller, B., Gebauer, M., & Töppel, T. (2011) · Assembly Automation · doi:10.1108/01445151111172925 · Cited by 70 · cited 1×
“[29] fabricated a miniature water cooler unit using AlSi10Mg material and showcased that the process of SLM allowed a better design approach to improving efficiency as delicate and complex geometries were buildable.”
MethodTheoretical study of the effective thermal conductivity of graphite foam based on a unit cell model
Leong, K. C., & Li, H. Y. (2011) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2011.07.042 · Cited by 47 · cited 1×
“Leong and Li [17] used a unit cell model to represent the pore structure of graphite foam in order to obtain the effective thermal conductivity.”
MethodSelf-citationHo, J. Y., & Leong, K. C. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.04.101 · Cited by 43 · cited 4×
“More recently, Leong et al. [4] conducted a review of pool boiling heat transfer of dielectric fluids on enhanced surfaces.”
BackgroundSelf-citationA free-particles-based technique for boiling heat transfer enhancement in a wetting liquid
Kim, T. Y., Weibel, J. A., & Garimella, S. V. (2014) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2013.12.070 · Cited by 38
Cited by
Chen, L.-Y., Liang, S.-X., Liu, Y., & Zhang, L.-C. (2021) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2021.100648 · Cited by 603
State-of-the-art in heat exchanger additive manufacturing
Kaur, I., & Singh, P. (2021) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2021.121600 · Cited by 319
Jafari, D., & Wits, W. W. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.03.109 · Cited by 289
A review on integration of lightweight gradient lattice structures in additive manufacturing parts
Seharing, A., Azman, A. H., & Abdullah, S. (2020) · Advances in Mechanical Engineering · doi:10.1177/1687814020916951 · Cited by 270
High performance, microarchitected, compact heat exchanger enabled by 3D printing
Dixit, T., Al-Hajri, E., Paul, M. C., Nithiarasu, P., & Kumar, S. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.118339 · Cited by 247
“Corresponding to the hot fluid Reynolds number Re h of 10 (cid:0) 40, overall heat transfer coefficient of the designed gyroid compact heat exchanger is in the range of 120 (cid:0) 160 W / m 2 K .”
Metadata
- Authors
- Wong, K. K., & Leong, K. C.
- Venue
- International Journal of Heat and Mass Transfer
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 121
- Pages
- 46-63
- ISSN
- 0017-9310 (ISSN-L)
- OpenAlex
- W2781681773
- Cited by
- 168
- References
- 23
- FWCI
- 11.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.