Heat transfer enhancement in a parallel, finless heat exchanger using a longitudinal vortex generator, Part B: Experimental investigation on the performance of finless and fin-tube heat exchangers
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The thermal performance of finless heat exchangers is lower than that of louver fin heat exchangers under dry conditions.
“However, the thermal performance of finless heat exchangers is lower than that of louver fin heat exchangers under dry conditions.”
In finless heat exchangers, condensate can drop rapidly under the influence of gravity because there are no fins in the way.
“For finless heat exchangers, the condensate can drop rapidly under the influence of gravity because there are no fins in the way, as shown in Fig. 19 (b).”
Under wet conditions, the finless heat exchanger with LVG performs similarly to the louver fin heat exchanger in terms of thermal-hydraulic performance due to its excellent drainage performance.
“Under wet conditions, the finless heat exchanger with LVG performed similarly to the louver fin heat exchanger in terms of thermal-hydraulic performance due to its excellent drainage performance.”
Cites
Heat transfer and pressure drop characteristics of flat tube and louvered plate fin surfaces
Achaichia, A., & Cowell, T. A. (1988) · Experimental Thermal and Fluid Science · doi:10.1016/0894-1777(88)90032-5 · Cited by 235 · see citing works
Xia, Y., Zhong, Y., Hrnjak, P. S., & Jacobi, A. M. (2006) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2006.03.005 · Cited by 148 · see citing works
Zhang, P., & Hrnjak, P. S. (2009) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2008.11.006 · Cited by 75 · see citing works
Xu, B., Han, Q., Chen, J., Li, F., Wang, N., Li, D., & Pan, X. (2013) · Applied Energy · doi:10.1016/j.apenergy.2012.09.026 · Cited by 71 · see citing works
Xu, B., Zhang, C., Wang, Y., Chen, J., Xu, K., Li, F., & Wang, N. (2015) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.06.037 · Cited by 69 · see citing works
Experimental investigation of frost formation on a parallel flow evaporator
Wu, J., Ouyang, G., Hou, P., & Xiao, H. (2011) · Applied Energy · doi:10.1016/j.apenergy.2010.11.006 · Cited by 53 · see citing works
Kim, M.-H., Song, S., & Bullard, C. W. (2002) · International Journal of Refrigeration · doi:10.1016/s0140-7007(01)00061-5 · Cited by 39 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Lim, H., Han, U., & Lee, H. (2020) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.114609 · Cited by 31 · see citing works
Xiong, T., Liu, G., Gao, Q., Yan, G., & Yu, J. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105654 · Cited by 26 · see citing works
- Authors
- Li, J., Dang, C., & Hihara, E.
- Affiliations
- The University of Tokyo (JP)
- Corresponding author
- Li, Jiyang
- Venue
- International Journal of Heat and Mass Transfer
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 128
- Pages
- 66-75
- ISSN
- 0017-9310 (ISSN-L)
- OpenAlex
- W2889198968
- Cited by
- 35
- References
- 7
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 6 · 2023: 2 · 2022: 4 · 2021: 6 · 2020: 5 · 2019: 2
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Heat and Mass Transfer (publishedVersion)
- Funders
- New Energy and Industrial Technology Development Organization
- China Scholarship Council
- Ministry of Education, Culture, Sports, Science and Technology
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer Mechanisms
- Physical Sciences › Engineering › Mechanical Engineering › Ranque-Hilsch vortex tube
- Keywords
- finned tube heat exchanger, longitudinal vortex generators, air-side pressure drop, thermal transmittance, louvered fins, slit fins, fin spacing, wet conditions, air-to-air heat exchanger, drainage performance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review