Cited by 71Refrigeration and Air Conditioning TechnologiesHeat Transfer and OptimizationAdsorption and Cooling Systems

Experimental investigation of frost and defrost performance of microchannel heat exchangers for heat pump systems

Xu, Bo, Han, Qing, Chen, Jiangping, Li, Feng, Wang, Nianjie, Li, Dong, Pan, Xiaoyong·2013·Applied Energy

Integrity signals

Registry

Crossref · 10.1016/j.apenergy.2012.09.026

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

1 of the 17 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Xu, B., Han, Q., Chen, J., Li, F., Wang, N., Li, D., & Pan, X.
Affiliations
  • Shanghai Jiao Tong University (CN)
  • Changhong (China) (CN)
Corresponding author
Xu, Bo
Venue
Applied Energy
Publisher
Elsevier BV
Published
2013-03
Volume
103
Pages
180-188
ISSN
0306-2619 (ISSN-L)
OpenAlex
W2000834065
Cited by
71
References
17
Citations by year
2026: 4 · 2025: 5 · 2024: 5 · 2023: 5 · 2022: 9 · 2021: 10 · 2020: 7 · 2019: 4 · 2018: 3 · 2017: 6 · 2016: 6 · 2015: 3 · 2014: 3 · 2013: 1
FWCI
3.42
Type
journal article
Language
en
Open access
closed
Locations
  • Applied Energy (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
Funders
Shanghai Jiao Tong University
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
Keywords
microchannel heat exchangers, frost formation, thawing, heat pumps, ice blockage, water retention, pressure drop, heat exchanger capacity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review