Embedded cooling with 3D manifold for vehicle power electronics application: Single-phase thermal-fluid performance
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Abstract Single-phase thermal-fluidic performance of an embedded silicon microchannel cold-plate (25 parallel channels: 75 μm × 150 μm) with a 3-D liquid distribution manifold (6 inlets: 700 μm × 150 μm) and vapor extraction conduits, is investigated using water as working fluid. A 3D manifold is fabricated from silicon and bonded to a silicon microchannel substrate to form a monolithic microcooler (μ-cooler). A metal serpentine bridge (52 mm2 of footprint) and multiple resistance temperature detectors (RTDs) are used for electrical Joule-heating and thermometry, respectively. The experimental results for maximum and average temperatures of the chip, pressure drop, thermal resistance (as low as 0.68 K/W), average heat transfer coefficient (∼30,000–50,000 W/m2 K) for flow rates of 0.03, 0.06 and 0.1 l/min and heat fluxes of 60, 100 and 250 W/cm2 are reported. The embedded microchannel-3D manifold μ-cooler device is capable of removing 250 W/cm2 at a maximum temperature of 90 °C with less than 3 kPa pressure drop for a flow rate of 0.1 l/min. The results from conjugate thermal-fluidic numerical simulations agree well with the experimental data over the wide range of heat fluxes and flow conditions. The numerical simulation results also hint at the possibility of removing up to ∼850 W/cm2 using single-phase water at a maximum temperature of 166 °C at the same pressure drop and flow rate. This offers a very attractive strategy/option for cooling of high heat flux power electronics using single-phase water.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of Heat and Mass Transfer
Azim, A. Y. A. (2011) · Cited by 5,433
High-performance heat sinking for VLSI
Tuckerman, D. B., & Pease, R. F. W. (1981) · IEEE Electron Device Letters · doi:10.1109/edl.1981.25367 · Cited by 5,291
Fundamentals of Heat and Mass Transfer
Incropera, F. P. (1985) · Cited by 3,677
ASME International Mechanical Engineering Congress and Exposition
(2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.4776777 · Cited by 2,619
Three-dimensional numerical optimization of a manifold microchannel heat sink
Ryu, J. H., Choi, D. H., & Kim, S. J. (2003) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(02)00443-x · Cited by 262 · cited 1×
“[5] numerical simulation results indicated that an optimized manifold design reduced the thermal resistance by 50% compared to a traditional microchannel heat sink.”
BackgroundDrummond, K. P., Back, D., Sinanis, M. D., Janes, D. B., Peroulis, D., Weibel, J. A., & Garimella, S. V. (2018) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.05.127 · Cited by 185 · cited 2×
“[18,19] also developed intrachip heat sink systems that consist of multi-layer hierarchical manifolds, and demonstrated the effects of cooling channel dimensions and mass flux on the maximum heat flux dissipation [18] and the heat transfer coefficient [19] while uniform background heat fluxes with simultaneous hotspot…”
BackgroundMicro-channel heat exchanger optimization
Harpole, G. M., & Eninger, J. E. (2002) · 1991 Proceedings, Seventh IEEE Semiconductor Thermal Measurement and Management Symposium · doi:10.1109/stherm.1991.152913 · Cited by 184 · cited 2×
“Early numerical modeling in the topic of 3D manifold liquid delivery configuration was performed by Harpole and Eninger [4] who predicted heat transfer coefficients on the order of 100,000 W/m(2) K.”
MethodNext Generation Microchannel Heat Exchangers
Ohadi, M. M., Choo, K., Dessiatoun, S. V., & Çetegen, E. (2012) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-1-4614-0779-9 · Cited by 142 · cited 4×
“1 lit/min and at the maximum heat flux of 250 W/cm(2), we estimate the Theater,max, Tch,base and Tf,exit using the reduced order thermofluidic model detailed in [15], Fig.”
BackgroundMethodInfluentialManifold microchannel heat sink design using optimization under uncertainty
Sarangi, S., Bodla, K. K., Garimella, S. V., & Murthy, J. Y. (2013) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2013.09.067 · Cited by 136 · cited 1×
“[12] examined the impact of manufacturing tolerances on optimization of manifold microchannel heat sinks.”
BackgroundArie, M., Shooshtari, A. H., Dessiatoun, S. V., Hajri, E. A., & Ohadi, M. M. (2014) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2014.10.022 · Cited by 124
Cited by
Co-designing electronics with microfluidics for more sustainable cooling
van Erp, R., Soleimanzadeh, R., Nela, L., Kampitsis, G., & Matioli, E. (2020) · Nature · doi:10.1038/s41586-020-2666-1 · Cited by 1,142
A comprehensive review on microchannel heat sinks for electronics cooling
Yu, Z.-Q., Li, M.-T., & Cao, B.-Y. (2024) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/ad12d4 · Cited by 218
Metadata
- Authors
- Jung, K. W., Kharangate, C. R., Lee, H., Palko, J., Zhou, F., Asheghi, M., Dede, E. M., & Goodson, K. E.
- Venue
- International Journal of Heat and Mass Transfer
- Publisher
- Elsevier BV
- Published
- 2019-03
- Volume
- 130
- Pages
- 1108-1119
- ISSN
- 0017-9310 (ISSN-L)
- OpenAlex
- W2901693299
- Cited by
- 192
- References
- 19
- FWCI
- 5.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Embedded cooling with 3D manifold for vehicle power electronics application: Single-phase thermal-fluid performance. https://app.cochat.ai/papers/10.1016/j.ijheatmasstransfer.2018.10.108
- The paper
- Jung, K. W., Kharangate, C. R., Lee, H., Palko, J., Zhou, F., Asheghi, M., Dede, E. M., & Goodson, K. E. (2019). Embedded cooling with 3D manifold for vehicle power electronics application: Single-phase thermal-fluid performance. International Journal of Heat and Mass Transfer. https://doi.org/10.1016/j.ijheatmasstransfer.2018.10.108
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.