An Eulerian multiphase frost model based on heat transfer measurements

Saygin, Alper, Basol, Altug Melik, Arik, Mehmet · 2023 · International Journal of Heat and Mass Transfer

Abstract

In this paper, a laminar numerical model is developed to predict frost formation over a horizontal cold flat surface. An Eulerian-Eulerian multiphase approach is followed to model humid air and ice phases separately. Frost accumulation on the cold surface is modeled with an empirical mass source term. Model constants were tuned in a systematic way using experimental heat flux and frost thickness data. A velocity dependent model constant is introduced into the mass source term. The heat flux rise observed experimentally at the initial stages of the frosting could be captured with the use of the velocity dependent model constant and the addition of this term considerably improved the accuracy of the frost model at the initial stages of frosting. It was also observed that the selected particle diameter for the solid ice phase has a considerable effect on the velocity profile over the frost layer. This requires tuning of the velocity dependent model constant parameters according to the selected ice particle diameter. The developed numerical model was tested with three different frost thermal conductivity models. Using the thermal conductivity of solid ice for the frost thermal conductivity resulted in the most accurate prediction at the early stages of the frost growth process indicating a rather column-wise vertical growth of ice crystals with very low lateral branching. However, the overprediction of the numerical heat flux with the thermal conductivity of solid ice points out a decrease in the thermal conductivity of the newly added frost layers indicating a more pronounced lateral branching of ice crystals within the frost layer. The effect of the diffusion coefficient of the water vapor in humid air on frosting is also investigated. An artificial increase in the diffusion coefficient improved the accuracy of the heat flux prediction of the model at the initial stages of frosting which might indicate an eddy-driven enhanced mixing in the boundary layer which might not be captured in the laminar flow model. Finally, the developed numerical model is also tested on another scenario with the surface temperature held at -30 °C. Detailed analysis of the numerical simulations showed a more porous frost layer with the surface temperature at -30 °C as compared to the frost porosity formed on the surface at -20 °C.

Overview

CoChat Summary

TL;DR

A laminar Eulerian–Eulerian multiphase CFD model was developed to predict frost formation over a horizontal cold flat plate, using an empirical mass source term tuned with experimental heat flux and frost thickness data. The model introduced a velocity-dependent coefficient and was tested against thermal conductivity and diffusion-coefficient variants, capturing initial heat-flux rise and later decline.

Key findings

  • A velocity-dependent coefficient κ in the frost mass source term improved initial-stage predictions; with τ = 80, initial heat flux was predicted with less than 5% error for the two considered surface temperatures. Threshold tests showed 3 cm/s underpredicted frost thickness and >5 cm/s overpredicted it; a continuous limiter with u_min = 1 cm/s and u_max = 5 cm/s gave better agreement.
  • Ice particle diameter affected drag and velocity profile: reducing diameter from 10 µm to 5 µm increased heat-flux decay in the first 10 min, while 20 µm reduced the drop; κ thresholds needed retuning for the 20 µm case.
  • Among three frost thermal conductivity models, using the thermal conductivity of solid ice best matched initial heat flux, indicating column-wise vertical growth with low lateral branching; later overprediction indicated decreasing conductivity and more lateral branching. The Negrelli model best matched frost thickness.
  • Increased water-vapor diffusion coefficient improved initial heat-flux prediction but overpredicted later; the real coefficient best predicted later stages. At a −30 °C surface, frost was more porous than at −20 °C; after 1 h the model underpredicted frost thickness by about 5 mm.

Methods

  • 2D transient Eulerian–Eulerian multiphase CFD of humid air and solid ice; laminar, with turbulence, gravity, and sublimation neglected and a constant water-vapor diffusion coefficient. The mass source term was based on supersaturation with empirical τ and velocity-dependent κ; ice particle diameter was set to 10 µm.
  • Computational domain used a velocity inlet, pressure outlet, adiabatic no-slip walls, and a fixed-temperature no-slip cold wall; initial humid air was 298 K and humidity ratio 10.256 g/kg; time step was 1.0 s; grid sensitivity led to 100 × 100 µm cells near the cold plate.
  • Experimental validation used a closed-loop wind tunnel with a climate chamber, test section, test vehicle with thermoelectric coolers, heat flux sensor, thermocouples, and high-speed camera; frost thickness was obtained via MATLAB image processing; experiments ran for 1 h. Model constants were tuned using initial heat flux and frost thickness data.

Limitations

  • Stated: the empirical mass source term requires experimental data to determine constants; the model considers only water-vapor deposition, neglects sublimation, gravity, turbulence, and uses a constant diffusion coefficient; ice particle diameter requires κ tuning; leading-edge frost thickness is less accurate; after 1 h thickness is underpredicted by about 5 mm.
  • Evident from the text: validation is limited to a single flat-plate geometry and specific environmental conditions; the laminar assumption may miss eddy-driven mixing, as suggested by improved initial heat flux with an artificially increased diffusion coefficient; the 2D approach cannot resolve local 3D crystal morphology or roughness effects.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1016/j.ijheatmasstransfer.2023.124575

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 1 Not valid · 5 Not checked · 98 Own results and interpretations

59 more claims

Create a free account to see all 104 claims and to verify the 4 references still open.

See all claims — free account
  • The quote only partly states this claim. 1
  • It may state two separate claims as one. 35
  • Probably not a substantial claim. 8

Create a free account to see these claims.

Citations

Cites

Show all 32 references

Cited by

See all 13

Metadata

Authors
Saygin, A., Basol, A. M., & Arik, M.
Affiliations
Özyeğin University (TR)
Venue
International Journal of Heat and Mass Transfer
Publisher
Elsevier BV
Published
2023-12
Volume
216
Pages
124575
ISSN
0017-9310 (ISSN-L)
OpenAlex
W4386017195
Cited by
13
References
32
Citations by year
2026: 3 · 2025: 5 · 2024: 3 · 2023: 2
FWCI
1.43
Type
journal article
Language
en
Open access
closed
Locations
International Journal of Heat and Mass Transfer (publishedVersion)
Topics
  • Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Particle Dynamics in Fluid Flows
Keywords
frost formation, Eulerian multiphase model, frost growth, heat flux prediction, frost thickness, ice crystal growth, boundary layer mixing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-17, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-17 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Eulerian multiphase frost model based on heat transfer measurements. https://app.cochat.ai/papers/10.1016/j.ijheatmasstransfer.2023.124575
The paper
Saygin, A., Basol, A. M., & Arik, M. (2023). An Eulerian multiphase frost model based on heat transfer measurements. International Journal of Heat and Mass Transfer. https://doi.org/10.1016/j.ijheatmasstransfer.2023.124575

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.