Barriers and facilitators to the use of computer-based intensive insulin therapy
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Purpose Computerized clinical decision support systems (CDSSs) for intensive insulin therapy (IIT) are increasingly common. However, recent studies question IIT’s safety and mortality benefit. Researchers have identified factors influencing IIT performance, but little is known about how workflow affects computer-based IIT. We used ethnographic methods to evaluate IIT CDSS with respect to other clinical information systems and care processes. Methods We conducted direct observation of and unstructured interviews with nurses using IIT CDSS in the surgical and trauma intensive care units at an academic medical center. We observed 49 hours of intensive care unit workflow including 49 instances of nurses using IIT CDSS embedded in a provider order entry system. Observations focused on the interaction of people, process, and technology. By analyzing qualitative field note data through an inductive approach, we identified barriers and facilitators to IIT CDSS use. Results Barriers included (1) workload tradeoffs between computer system use and direct patient care, especially related to electronic nursing documentation, (2) lack of IIT CDSS protocol reminders, (3) inaccurate user interface design assumptions, and (4) potential for error in operating medical devices. Facilitators included (1) nurse trust in IIT CDSS combined with clinical judgment, (2) nurse resilience, and (3) paper serving as an intermediary between patient bedside and IIT CDSS. Conclusion This analysis revealed sociotechnical interactions affecting IIT CDSS that previous studies have not addressed. These issues may influence protocol performance at other institutions. Findings have implications for IIT CDSS user interface design and alerts, and may contribute to nascent general CDSS theory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Griesdale, D. E. G., de Souza, R. J., van Dam, R. M., Heyland, D. K., Cook, D. J., Malhotra, A., Dhaliwal, R., Henderson, W. R., Chittock, D. R., Finfer, S., et al. (2009) · Canadian Medical Association Journal · doi:10.1503/cmaj.090206 · Cited by 1,096
Preiser, J.-C., Devos, P., Ruiz-Santana, S., Mélot, C., Annane, D., Groeneveld, J., Iapichino, G., Leverve, X., Nitenberg, G., Singer, P., et al. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1585-2 · Cited by 911 · cited 1×
“Intensive insulin therapy (IIT) is the standard of critical care, but recent studies raise questions about the therapy’s mortality benefit and risk to patients [1-4].”
Medication-related clinical decision support in computerized provider order entry systems: a review
Kuperman, G. J., Bobb, A., Payne, T. H., Avery, A. J., Gandhi, T. K., Burns, G., Classen, D. C., & Bates, D. W. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2170 · Cited by 763 · cited 1×
“Alert fatigue is a concern in clinical informatics [34-35], and the passive alerts observed in this study, provided through the nurse medication scheduling tool and dashboard, appeared effective to varying degrees for non-IIT nursing tasks.”
Kaplan, B. (2001) · International Journal of Medical Informatics · doi:10.1016/s1386-5056(01)00184-8 · Cited by 380
Patterson, E. S., Cook, R. I., & Render, M. L. (2002) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1061 · Cited by 370
Benefits and Risks of Tight Glucose Control in Critically Ill Adults: A Meta-analysis
Wiener, R. S., Wiener, D. C., & Larson, R. J. (2008) · JAMA · doi:10.1001/jama.300.8.933 · Cited by 200 · cited 1×
“Intensive insulin therapy (IIT) is the standard of critical care, but recent studies raise questions about the therapy’s mortality benefit and risk to patients [1-4].”
Blood glucose variability is associated with mortality in the surgical intensive care unit
Dossett, L. A., Cao, H., Mowery, N. T., Dortch, M. J., Morris, J. M., & May, A. K. (2008) · The American Surgeon™ · doi:10.1177/000313480807400802 · Cited by 190
Self-citationHuman Factors Barriers to the Effective Use of Ten HIV Clinical Reminders
Patterson, E. S., Nguyen, A. D., Halloran, J. P., & Asch, S. M. (2004) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1364 · Cited by 115 · cited 2×
“Scholars have noted the paucity of theory in biomedical informatics research [39-40], but the common themes identified by previous studies [34, 37-38] and this investigation—limiting the number of reminders, reducing the perception that management benefits more from system use than end users, eliminating double docume…”
Tight glycaemic control by an automated algorithm with time-variant sampling in medical icu patients
Pachler, C., Plank, J., Weinhandl, H., Chassin, L. J., Wilinska, M. E., Kulnik, R., Kaufmann, P., Smolle, K.-H., Pilger, E., Pieber, T. R., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1033-8 · Cited by 82 · cited 1×
“Capturing more parameters in IIT CDSS could also facilitate use of more sophisticated dosing algorithms that incorporate dextrose sources [32].”
Cited by
Artificial Intelligence Applications in Health Care Practice: Scoping Review
Sharma, M., Savage, C., Nair, M., Larsson, I., Svedberg, P., & Nygren, J. M. (2022) · Journal of Medical Internet Research · doi:10.2196/40238 · Cited by 198
“Nearly three-quarters of all AI systems were intended for clinical care (n=33) (50,53,55,57–63,65,67–77,82–84,88–93) and the majority of these concerned providing support to inform the patient-provider encounter (n = 18) (50,53,55,59,60,65,67,69,71,72,78,82,83,88,89,91,93), followed by diagnosis and prediction-based d…”
InfluentialAbell, B., Naicker, S., Rodwell, D., Donovan, T., Tariq, A., Baysari, M., Blythe, R., Parsons, R., & McPhail, S. M. (2023) · Implementation Science · doi:10.1186/s13012-023-01287-y · Cited by 131
Miller, A., Moon, B., Anders, S., Walden, R., Brown, S., & Montella, D. (2015) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2015.09.005 · Cited by 106
Integrative review of clinical decision support for registered nurses in acute care settings
Dunn Lopez, K., Gephart, S. M., Raszewski, R., Sousa, V., Shehorn, L. E., & Abraham, J. (2017) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocw084 · Cited by 83
Scheepers-Hoeks, A.-M. J., Grouls, R. J., Neef, C., Ackerman, E. W., & Korsten, E. H. (2013) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2013.05.002 · Cited by 53
Metadata
- Authors
- Campion, T. R., Waitman, L. R., Lorenzi, N. M., May, A. K., & Gadd, C. S.
- Venue
- International Journal of Medical Informatics
- Publisher
- Elsevier BV
- Published
- 2011-12
- Volume
- 80
- Issue
- 12
- Pages
- 863-871
- ISSN
- 1386-5056 (ISSN-L)
- OpenAlex
- W2049588843
- Cited by
- 38
- References
- 9
- FWCI
- 3.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Barriers and facilitators to the use of computer-based intensive insulin therapy. https://app.cochat.ai/papers/10.1016/j.ijmedinf.2011.10.003
- The paper
- Campion, T. R., Waitman, L. R., Lorenzi, N. M., May, A. K., & Gadd, C. S. (2011). Barriers and facilitators to the use of computer-based intensive insulin therapy. International Journal of Medical Informatics. https://doi.org/10.1016/j.ijmedinf.2011.10.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.