The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Metabolic profiling of human blood by high-resolution ion mobility mass spectrometry (IM-MS)
Open accessAbstract
A high resolution ion mobility time-of-flight mass spectrometer with electrospray ionization source (ESI-IM-MS) was evaluated as an analytical method for rapid analysis of complex biological samples such as human blood metabolome was investigated. The hybrid instrument (IM-MS) provided an average ion mobility resolving power of ~90 and a mass resolution of ~1500 (at m/z 100). A few µL of whole blood was extracted with methanol, centrifuged and infused into the IM-MS via an electrospray ionization source. Upon IM-MS profiling of the human blood metabolome approximately 1,100 metabolite ions were detected and 300 isomeric metabolites separated in short analyses time (30 minutes). Estimated concentration of the metabolites ranged from the low micromolar to the low nanomolar level. Various classes of metabolites (amino acids, organic acids, fatty acids, carbohydrates, purines and pyrimidines etc) were found to form characteristic mobility-mass correlation curves (MMCC) that aided in metabolite identification. Peaks corresponding to various sterol derivatives, estrogen derivatives, phosphocholines, prostaglandins, and cholesterol derivatives detected in the blood extract were found to occupy characteristic two dimensional IM-MS space. Low abundance metabolite peaks that can be lost in MS random noise were resolved from noise peaks by differentiation in mobility space. In addition, the peak capacity of MS increased six fold by coupling IMS prior to MS analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Caulfield, M. P., Lynn, T., Gottschalk, M. E., Jones, K. L., Taylor, N. F., Malunowicz, E. M., Shackleton, C. H. L., Reitz, R. E., & Fisher, D. A. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.87.8.8712 · Cited by 120
Cited by
Cajka, T., & Fiehn, O. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04491 · Cited by 830
Current approaches and challenges for the metabolite profiling of complex natural extracts
Wolfender, J.-L., Marti, G., Thomas, A., & Bertrand, S. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.10.091 · Cited by 635
Lapthorn, C., Pullen, F., & Chowdhry, B. Z. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21349 · Cited by 398
Kuehnbaum, N. L., & Britz-McKibbin, P. (2013) · Chemical Reviews · doi:10.1021/cr300484s · Cited by 354
Advances in metabolite identification
Wishart, D. S. (2011) · Bioanalysis · doi:10.4155/bio.11.155 · Cited by 284
Metadata
- Authors
- Dwivedi, P., Schultz, A. J., & Jr, H. H. H.
- Venue
- International Journal of Mass Spectrometry
- Publisher
- Elsevier BV
- Published
- 2010-12
- Volume
- 298
- Issue
- 1-3
- Pages
- 78-90
- ISSN
- 1387-3806 (ISSN-L)
- OpenAlex
- W2104732216
- Cited by
- 168
- References
- 1
- FWCI
- 6.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Metabolic profiling of human blood by high-resolution ion mobility mass spectrometry (IM-MS). https://app.cochat.ai/papers/10.1016/j.ijms.2010.02.007
- The paper
- Dwivedi, P., Schultz, A. J., & Jr, H. H. H. (2010). Metabolic profiling of human blood by high-resolution ion mobility mass spectrometry (IM-MS). International Journal of Mass Spectrometry. https://doi.org/10.1016/j.ijms.2010.02.007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.