Why and how to prepare biodegradable, monodispersed, polymeric microparticles in the field of pharmacy?
The DOI matches its Crossref record; 106 of the 106 references it cites were found in a registry or an index.
Abstract
Drug delivery via biodegradable microparticles benefits from both the protection of the encapsulated drug from hazardous conditions and the controlled release of the encapsulated drug, thereby reducing the administration frequency and improving patient compliance. Microsphere-size particle distribution is considered as being an important factor that affects the choice of the administration route and the drug-release rate. Significant research efforts have been directed towards the production of monodispersed "designer" particles. Amongst various techniques, some have been examined from lab-scale to industrial-scale. This review provides a global overview of monodispersed microparticle production methods and then focuses on recent processes being used to produce biodegradable microparticles applied in the pharmaceutical field. Further discussion about the choice of process according to the microparticle objectives of use is suggested.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00048-3 · Cited by 2,617
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302 · cited 2×
“The outer phase has a flow rate several orders of magnitude higher than the inner dispersal phase (Anna et al., 2003; Schneider et al., 2008).”
BackgroundBiomedical applications of collagen
Lee, C. H., Singla, A., & Lee, Y. (2001) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(01)00691-3 · Cited by 1,945
Athanasiou, K. A., Niederauer, G. G., & Agrawal, C. M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85754-1 · Cited by 1,497
Physical approaches to biomaterial design
Mitragotri, S., & Lahann, J. (2009) · Nature Materials · doi:10.1038/nmat2344 · Cited by 1,445 · cited 1×
“Microspheres should therefore e sufficiently large to contain a reasonable amount of active ingreient but not so large as to cause discomfort upon administration Mitragotri and Lahann, 2009; Wang et al., 1997).”
BackgroundPolymer microspheres for controlled drug release
Freiberg, S., & Zhu, X. X. (2004) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2004.04.013 · Cited by 1,336
Zum Zerfall eines Flüssigkeitsstrahles
Weber, C. (1931) · ZAMM - Journal of Applied Mathematics and Mechanics / Zeitschrift für Angewandte Mathematik und Mechanik · doi:10.1002/zamm.19310110207 · Cited by 1,034
Freitas, S., Merkle, H. P., & Gander, B. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.10.015 · Cited by 923 · cited 2×
“The resulting spray shows significant polydispersity in this case (Gañán-Calvo, 1998).”
BackgroundEncyclopedia Of Controlled Drug Delivery
Mathiowitz, E. (1999) · Medical Entomology and Zoology · Cited by 855
Mathematical modeling of bioerodible, polymeric drug delivery systems
Siepmann, J. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00116-8 · Cited by 772
Boontheekul, T., Kong, H.-J., & Mooney, D. J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.044 · Cited by 659 · cited 1×
“The jet-excitation process was patented for the production of uniform microspheres of alginate (Brandau, 1995), collagen (Dumas, 1992) and PLGA (Berkland et al., 2003b; Kim et al., 2008).”
MethodXu, Q., Hashimoto, M., Dang, T. T., Hoare, T., Kohane, D. S., Whitesides, G. M., Langer, R., & Anderson, D. G. (2009) · Small · doi:10.1002/smll.200801855 · Cited by 602
Microencapsulation by solvent evaporation: State of the art for process engineering approaches
Li, M., Rouaud, O., & Poncelet, D. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2008.07.018 · Cited by 590
Perfectly Monodisperse Microbubbling by Capillary Flow Focusing
Gañán-Calvo, A. M., & Gordillo, J. M. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.274501 · Cited by 587
Membrane emulsification — a literature review
Joscelyne, S. M., & Trägårdh, G. (2000) · Journal of Membrane Science · doi:10.1016/s0376-7388(99)00334-8 · Cited by 576
Generation of Steady Liquid Microthreads and Micron-Sized Monodisperse Sprays in Gas Streams
Gañán-Calvo, A. M. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.285 · Cited by 531 · cited 2×
“The resulting spray shows significant polydispersity in this case (Gañán-Calvo, 1998).”
BackgroundSize-Dependent Bioadhesion of Micro- and Nanoparticulate Carriers to the Inflamed Colonic Mucosa
Lamprecht, A., Schäfer, U., & Lehr, C.-M. (2001) · Pharmaceutical Research · doi:10.1023/a:1011032328064 · Cited by 507
Dunne, M., Corrigan, O. I., & Ramtoola, Z. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00040-5 · Cited by 444
Redhead, H. M., Davis, S. S., & Illum, L. (2001) · Journal of Controlled Release · doi:10.1016/s0168-3659(00)00367-9 · Cited by 419
Degradable Polymer Microspheres for Controlled Drug Delivery
Edlund, U., & Albertsson, A. C. (2002) · Advances in Polymer Science · doi:10.1007/3-540-45734-8_3 · Cited by 416 · cited 1×
“…ources and their controllable degradation rate via their molecular eight and the modification of the ratio of lactic acid/glycolic acid Edlund and Albertsson, 2002; Stevanović and Uskoković, 2009). ecently, there has been a trend of using copolymers of PLGA and oly (ethylene glycol)…”
MethodRegular‐sized cell creation in microchannel emulsification by visual microprocessing method
Kawakatsu, T., Kikuchi, Y., & Nakajima, M. (1997) · Journal of the American Oil Chemists' Society · doi:10.1007/s11746-997-0143-8 · Cited by 396
How porosity and size affect the drug release mechanisms from PLGA-based microparticles
Klose, D., Siepmann, F., Elkharraz, K., Krenzlin, S., & Siepmann, J. (2006) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2005.07.031 · Cited by 358
The membrane emulsification process—a review
Charcosset, C., Limayem, I., & Fessi, H. (2004) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.969 · Cited by 349 · cited 1×
“A constant (i.e., zero-order) release rate is often preferred to maintain an effective drug concentration in the host tissue (Chen and Lu, 1999).”
BackgroundFabrication of PLG microspheres with precisely controlled and monodisperse size distributions
Berkland, C., Kim, K. (., & Pack, D. W. (2001) · Journal of Controlled Release · doi:10.1016/s0168-3659(01)00289-9 · Cited by 336
Kissel, T., Li, Y., & Unger, F. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00244-7 · Cited by 332
Size control of calcium alginate beads containing living cells using micro-nozzle array
Sugiura, S., Oda, T., Izumida, Y., Aoyagi, Y., Satake, M., Ochiai, A., Ohkohchi, N., & Nakajima, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.08.029 · Cited by 320
Mohamed, F., & van der Walle, C. F. (2008) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21082 · Cited by 299
Ma, J., Wang, H., He, B., & Chen, J. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00188-5 · Cited by 295
Effect of the size of biodegradable microparticles on drug release: experiment and theory
Siepmann, J., Faisant, N., Akiki, J., Richard, J., & Benoit, J. P. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.01.011 · Cited by 272 · cited 1×
“By sieving the 5-FU-loaded PLGA microspheres of the ame formulation into various fractions of size from under 35 m o 125 m, Siepmann et al. (2004) found that initial drug loading ncreased with increasing microsphere size because large micropheres could contain both large and small drug crystals…”
MethodHow to achieve sustained and complete protein release from PLGA-based microparticles?
Giteau, A., Venier-Julienne, M. C., Aubert-Pouëssel, A., & Benoit, J. P. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2007.11.012 · Cited by 268
Self-citationWang, L.-Y., Ma, G.-H., & Su, Z.-G. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.04.005 · Cited by 235
Peptide and protein drug delivery
(1993) · Comparative Biochemistry and Physiology Part A: Physiology · doi:10.1016/0300-9629(93)90342-2 · Cited by 227
PLG Microsphere Size Controls Drug Release Rate Through Several Competing Factors
Berkland, C., Kim, K., & Pack, D. W. (2003) · Pharmaceutical Research · doi:10.1023/a:1024466407849 · Cited by 219
Berkland, C., Kipper, M. J., Narasimhan, B., Kim, K. (., & Pack, D. W. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2003.09.011 · Cited by 215
Microfluidic‐Assisted Synthesis of Polymer Particles
Serra, C. A., & Chang, Z. (2008) · Chemical Engineering & Technology · doi:10.1002/ceat.200800219 · Cited by 215 · cited 1×
“…al., 2002; Mathiowitz and Langer, 1999; V.-T. Tran et al. / International Journal of Pharmaceutics 407 (2011) 1–11 3 S o t o a s o c m b o s t G e ( p o l i m c w t i c r L d r e r d w b t a T o f t fi 2 s m m n t m this process ranged from 100 m to around 10 m (Gasparini et al., hi et al., 2003).”
BackgroundMartín‐Banderas, L., Flores‐Mosquera, M., Riesco‐Chueca, P., Rodríguez‐Gil, A., Cebolla, Á., Chávez, S., & Gañán‐Calvo, A. M. (2005) · Small · doi:10.1002/smll.200500087 · Cited by 206
Effect of the size of biodegradable microparticles on drug release: experiment and theory
Siepmann, J. (2004) · Journal of Controlled Release · doi:10.1016/j.conrel.2004.01.011 · Cited by 203
Vladisavljević, G. T. (2003) · Journal of Membrane Science · doi:10.1016/s0376-7388(03)00212-6 · Cited by 185
Uskokovic, D., & Stevanovic, M. (2009) · Current Nanoscience · doi:10.2174/157341309787314566 · Cited by 182
Encapsulation of protein drugs in biodegradable microparticles by co-axial electrospray
Xie, J., Ng, W. J., Lee, L. Y., & Wang, C.-H. (2008) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2007.09.082 · Cited by 181
Raman, C., Berkland, C., Kim, K. (., & Pack, D. W. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.11.012 · Cited by 166
Electrostatic micro- and nanoencapsulation and electroemulsification: A brief review
Jaworek, A. (2008) · Journal of Microencapsulation · doi:10.1080/02652040802049109 · Cited by 161
Lee, T. H., Wang, J., & Wang, C. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00235-3 · Cited by 159 · cited 4×
“These conventional core–shell microparticles were ften large (>150 m) and polydispersed (Lee et al., 2002).”
BackgroundInfluentialElectrostatic droplet generation: Mechanism of polymer droplet formation
Bugarski, B., Li, Q., Goosen, M. F. A., Poncelet, D., Neufeld, R. J., & Vunjak, G. (1994) · AIChE Journal · doi:10.1002/aic.690400613 · Cited by 149
Alginate-polylysine-alginate microcapsules: effect of size reduction on capsule properties
Strand, B. L., Gåserød, O., Kulseng, B., Espevik, T., & Skjåk-Bræk, G. (2002) · Journal of Microencapsulation · doi:10.1080/02652040210144243 · Cited by 146
Katare, Y. K., Muthukumaran, T., & Panda, A. K. (2005) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2005.05.028 · Cited by 145
Makino, K., Nakajima, T., Shikamura, M., Ito, F., Ando, S., Kochi, C., Inagawa, H., Soma, G., & Terada, H. (2004) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2004.03.018 · Cited by 145
Xie, J., & Wang, C. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21334 · Cited by 143
Genetically engineered polymers: status and prospects for controlled release
Haider, M. A., Megeed, Z., & Ghandehari, H. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2003.11.011 · Cited by 141 · cited 1×
“Various microsphere materials have been used for drugontrolled delivery (Haider et al., 2004; Kim, 1994; Passerini et al., 003).”
MethodInhalable large porous microspheres of low molecular weight heparin: In vitro and in vivo evaluation
Rawat, A., Majumder, Q. H., & Ahsan, F. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.03.013 · Cited by 136
Choi, D. H., Park, C. H., Kim, I. H., Chun, H. J., Park, K., & Han, D. K. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.07.103 · Cited by 133
Lee, Y.-H., Mei, F., Bai, M.-Y., Zhao, S., & Chen, D.-R. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.03.014 · Cited by 133
Uniform double-walled polymer microspheres of controllable shell thickness
Berkland, C., Pollauf, E., Pack, D. W., & Kim, K. (. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.01.018 · Cited by 131
Koch, S., Schwinger, C., Kreßler, J., Heinzen, C., & Rainov, N. G. (2003) · Journal of Microencapsulation · doi:10.3109/02652040309178071 · Cited by 128
Gaumet, M., Gurny, R., & Delie, F. (2009) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2008.11.015 · Cited by 115
Effect of viscosities of dispersed and continuous phases in microchannel oil-in-water emulsification
van Dijke, K. C., Kobayashi, I., Schroën, K. G. P. H., Uemura, K., Nakajima, M., & Boom, R. M. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0521-7 · Cited by 115
Production of Small, Monodispersed Alginate Beads for Cell Immobilization
Seifert, D. B., & Phillips, J. (1997) · Biotechnology Progress · doi:10.1021/bp9700723 · Cited by 109
Berchane, N. S., Carson, K. H., Rice-Ficht, A. C., & Andrews, M. J. (2007) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2006.12.037 · Cited by 108
Size effect of PLGA spheres on drug loading efficiency and release profiles
Dawes, G. J. S., Fratila-Apachitei, L. E., Mulia, K., Apachitei, I., Witkamp, G., & Duszczyk, J. (2009) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-008-3666-0 · Cited by 106
Preparation of Poly(D,L-lactide) and Copoly(lactide-glycolide) Microspheres of Uniform Size
Shiga, K., Muramatsu, N., & Kondo, T. (1996) · Journal of Pharmacy and Pharmacology · doi:10.1111/j.2042-7158.1996.tb05995.x · Cited by 102
Mass Production of Embryoid Bodies in Microbeads
Magyar, J. P., Nemir, M., Ehler, E., Suter, N., Perriard, J., & Eppenberger, H. M. (2001) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2001.tb03828.x · Cited by 100
Heinzen, C., Berger, A., & Marison, I. W. (2004) · Focus on biotechnology · doi:10.1007/978-94-017-1638-3_14 · Cited by 96
Huang, K., Lu, K., Yeh, C., Chung, S.-R., Lin, C., Yang, C., & Dong, Y.-S. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.02.019 · Cited by 95
Shi, M., Yang, Y. Y., Chaw, C. S., Goh, S.-H., Moochhala, S., Ng, S., & Heller, J. (2003) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00493-5 · Cited by 94
Production of Monodispersed Oil-in-Water Emulsion Using Crossflow-Type Silicon Microchannel Plate.
Kawakatsu, T., Komori, H., Nakajima, M., Kikuchi, Y., & Yonemoto, T. (1999) · JOURNAL OF CHEMICAL ENGINEERING OF JAPAN · doi:10.1252/jcej.32.241 · Cited by 93
Gasparini, G., Kosvintsev, S. R., Stillwell, M. T., & Holdich, R. G. (2007) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2007.08.011 · Cited by 91
Microspheres for protein delivery prepared from amphiphilic multiblock copolymers
Bezemer, J. M., van Dijkhuizen-Radersma, R., Grijpma, D. W., Dijkstra, P. J., van Blitterswijk, C., & Feijén, J. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(00)00213-3 · Cited by 90
Thomas, C., Gupta, V., & Ahsan, F. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0094-x · Cited by 88 · cited 1×
“Microparticle formation under aseptic conditions using sterile starting materials and sterility tests at each processing step could provide an answer (Brandenberger and Widmer, 1998; Toguchi, 1999).”
MethodPaillard, A., Tran, V.-T., Thomas, O., Garric, X., Coudane, J., Marchal, S., Chourpa, I., Benoît, J., Montero‐Menei, C. N., & Venier‐Julienne, M. (2010) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2010.03.005 · Cited by 86 · cited 1×
“…ecently, there has been a trend of using copolymers of PLGA and oly (ethylene glycol) (PEG), PLGA–PEG–PLGA, in drug delivery, specially for protein delivery, due to their highly hydrophilic charcteristics that facilitate drug release by diffusion (Kissel et al., 002; Paillard-Giteau et al., 2010).”
BackgroundSelf-citationAmsden, B. G., & Goosen, M. F. A. (1997) · Journal of Controlled Release · doi:10.1016/s0168-3659(96)01483-6 · Cited by 85 · cited 3×
“However, increasing the electric current induces a much broader diameter distribution (Amsden and Goosen, 1997; Bugarski et al., 1994a,b); the microsphere size is reduced to less than 100 m but their CV increases to over 15%.”
BackgroundInfluentialBiocompatible alginate from freshly collected Laminaria pallida for implantation
Jork, A., Thürmer, F., Cramer, H., Zimmermann, G., Geßner, P., Hamel, K., Hofmann, G., Kuttler, B., Hahn, H.-J., Josimovic‐Alasevic, O., et al. (2000) · Applied Microbiology and Biotechnology · doi:10.1007/s002530050012 · Cited by 81
Polystyrene Microspheres and Nanospheres Produced by Electrospray
Fantini, D., Zanetti, M., & Costa, L. (2006) · Macromolecular Rapid Communications · doi:10.1002/marc.200600532 · Cited by 81
Pharmacologically active microcarriers: a tool for cell therapy
Tatard-Leitman, V. M., Venier‐Julienne, M., Saulnier, P., Prechter, E., Benoît, J., Meneï, P., & Montero‐Menei, C. N. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.042 · Cited by 81
Self-citationSynthesis of lidocaine-loaded PLGA microparticles by flow focusing
Holgado, M. A., Arias, J. L., Cózar-Bernal, M. J., Álvarez‐Fuentes, J., Gañán‐Calvo, A. M., & Arévalo, M. F. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2008.02.012 · Cited by 81
Senuma, Y., Franceschin, S., Hilborn, J. G., Tissières, P., Bisson, I., & Frey, P. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00276-8 · Cited by 80
Electrohydrodynamic atomization of quasi-monodisperse drug-loaded spherical/wrinkled microparticles
Hong, Y., Li, Y., Yin, Y., Li, D., & Zou, G. (2008) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.02.004 · Cited by 80
Berkland, C. J., Pollauf, E. J., Raman, C., Silverman, R., Kim, K., & Pack, D. W. (2007) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20948 · Cited by 79
Monodisperse Liquid-filled Biodegradable Microcapsules
Berkland, C. J., Pollauf, E. J., Varde, N. K., Pack, D. W., & Kim, K. (2007) · Pharmaceutical Research · doi:10.1007/s11095-006-9197-9 · Cited by 70 · cited 1×
“…al., 2006; Leach et al., 2005); whereas larger particles with larger cores increased the length of the diffusion pathways and decreased drug concentration gradients; drugs thus took longer to be released (Bezemer et al., 2000; Dunne et al., 2000; Redhead et al., 2001; Siepmann and Göpferich, 2001).”
BackgroundTowards High‐Throughput Production of Uniformly Encoded Microparticles
Martín‐Banderas, L., Rodríguez‐Gil, A., Cebolla, Á., Chávez, S., Berdún‐Álvarez, T., Garcia, J. M. F., Flores, M. V., & Gañán‐Calvo, A. M. (2006) · Advanced Materials · doi:10.1002/adma.200501976 · Cited by 70
Preparation of monodispersed emulsion with large droplets using microchannel emulsification
Sugiura, S., Nakajima, M., & Seki, M. (2002) · Journal of the American Oil Chemists Society · doi:10.1007/s11746-002-0517-6 · Cited by 68
Wei, Q., Wei, W., Tian, R., Wang, L., Su, Z. G., & Ma, G. (2008) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2008.04.058 · Cited by 67
Berkland, C. J., Cox, A., Kim, K. K., & Pack, D. W. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30114 · Cited by 62
Wang, Y. M., Sato, H., & Horikoshi, I. (1997) · Journal of Controlled Release · doi:10.1016/s0168-3659(97)00082-5 · Cited by 59 · cited 2×
“The optimum wavelength ( ) or break-up is thus given by (Weber, 1931): = 4.443dj √ 3 √ dj + 1 here dj, , indicate the diameter of the jet, the density, and the nterfacial tension of polymer solution.”
BackgroundMethodEncapsulation of Ketoprofen and Ketoprofen Lysinate by Prilling for Controlled Drug Release
Gaudio, P. D., Russo, P., Lauro, M. R., Colombo, P., & Aquino, R. P. (2009) · AAPS PharmSciTech · doi:10.1208/s12249-009-9309-z · Cited by 59 · cited 1×
“The frequency is usually kept as low as possible in order to avoid the formation of satellite droplets leading to a broader size range (Del Gaudio et al., 2009).”
BackgroundMazzitelli, S., Tosi, A., Balestra, C., Nastruzzi, C., Luca, G., Mancuso, F., Calafiore, R., & Calvitti, M. (2008) · Journal of Biomaterials Applications · doi:10.1177/0885328207084958 · Cited by 57
Igartúa, M., Hernández, R. M., Rosas, J. E., Patarroyo, M. E., & Pedraz, J. L. (2007) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2007.12.014 · Cited by 57
Bocanegra, R., Sampedro, J. L., Gañán‐Calvo, A. M., & Márquez, M. (2005) · Journal of Microencapsulation · doi:10.1080/02652040500273639 · Cited by 55 · cited 5×
“The liquid core can be essential oils, plant extracts (coffee, menthol, citrus oil, etc.), drugs or cells in a culture medium (Berkland et al., 2007b; Bocanegra et al., 2005; Martín-Banderas et al., 2005; Nedovic and Willaert, 2004).”
BackgroundInfluentialDoan, T. V. P., & Olivier, J. (2009) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2009.08.008 · Cited by 55
Leelarasamee, N., Howard, S. A., Malanga, C. J., & Ma, J. K. H. (1988) · Journal of Microencapsulation · doi:10.3109/02652048809056478 · Cited by 54 · cited 1×
“A reduction of the injection diameter and an increase of the continuous phase velocity decreased microsphere size (Amsden, 1999; Leelarasamee et al., 1988; Xu et al., 2009a); this process is unsuitable for the production of small microspheres (<30 m) and their throughput was quite low (<2 mL/min)…”
BackgroundPollauf, E. J., Kim, K. K., & Pack, D. W. (2005) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20408 · Cited by 51
Encapsulation of liquid and solid aerosol particles to form dry powders
Langer, G., & Yamate, G. (1969) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(69)90125-8 · Cited by 50 · cited 1×
“The polymer covers the aqueous droplets forming the microcapsules (Langer and Yamate, 1969; Yeo et al., 2004).”
BackgroundEncapsulation of protein nanoparticles into uniform-sized microspheres formed in a spinning oil film
Leach, W. T., Simpson, D. T., Val, T. N., Yu, Z., Lim, K. T., Park, E. J., Williams, R. O., & Johnston, K. P. (2005) · AAPS PharmSciTech · doi:10.1208/pt060475 · Cited by 49
Solvent Exchange Method: A Novel Microencapsulation Technique Using Dual Microdispensers
Yeo, Y., Chen, A. U., Basaran, O. A., & Park, K. (2004) · Pharmaceutical Research · doi:10.1023/b:pham.0000036916.96307.d8 · Cited by 47 · cited 1×
“The polymer covers the aqueous droplets forming the microcapsules (Langer and Yamate, 1969; Yeo et al., 2004).”
BackgroundHolgado, M. A., Cózar-Bernal, M. J., Salas, S., Arias, J. L., Álvarez‐Fuentes, J., & Arévalo, M. F. (2009) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2009.07.017 · Cited by 35
Yamamoto, N., Fukai, F., Ohshima, H., Terada, H., & Makino, K. (2002) · Colloids and Surfaces B Biointerfaces · doi:10.1016/s0927-7765(01)00306-x · Cited by 34
High celecoxib-loaded nanoparticles prepared by a vibrating nozzle device
Pobirk, A. Z., Kristl, J., Kerč, J., & Grabnar, P. A. (2009) · Journal of Microencapsulation · doi:10.3109/02652040802584402 · Cited by 32 · cited 1×
“The production of microparticles by the vibrating nozzle device is highly reproducible, time saving, can be performed under aseptic and scaled-up conditions (Zvonar et al., 2009).”
BackgroundWang, W., Zhou, S., Sun, L., & Huang, C. (2009) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2009.08.031 · Cited by 30 · cited 1×
“Microspheres should therefore e sufficiently large to contain a reasonable amount of active ingreient but not so large as to cause discomfort upon administration Mitragotri and Lahann, 2009; Wang et al., 1997).”
BackgroundSchneider, T., Zhao, H., Jackson, J. K., Chapman, G. H., Dykes, J. M., & Häfeli, U. O. (2008) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21344 · Cited by 26
The Production of Uniformly Sized Polymer Microspheres
Amsden, B. G. (1999) · Pharmaceutical Research · doi:10.1023/a:1011968707321 · Cited by 25
Kobayashi, I., Iitaka, Y., Iwamoto, S., Kimura, S., & Nakajima, M. (2003) · JOURNAL OF CHEMICAL ENGINEERING OF JAPAN · doi:10.1252/jcej.36.996 · Cited by 22 · cited 1×
“2C) (Kawakatsu et al., 1999; Kobayashi et al., 2003; Sugiura t al., 2002b).”
Choy, Y. B., Choi, H., & Kim, K. (2007) · Macromolecular Bioscience · doi:10.1002/mabi.200700020 · Cited by 22
PLA and PLGA microparticles for intravitreal drug delivery: an overview
Herrero‐Vanrell, R., & Molina-Martínez, I. T. (2007) · Journal of Drug Delivery Science and Technology · doi:10.1016/s1773-2247(07)50002-x · Cited by 19
Sterility assurance of microspheres
Toguchi, H. (1999) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00023-1 · Cited by 15
He, Y. (2008) · Chemical Engineering Science · doi:10.1016/j.ces.2008.02.008 · Cited by 14
Gong, X., Lü, Y., Xiang, Z., Zhang, Y., & Luo, G. (2007) · Journal of Microencapsulation · doi:10.1080/02652040701640560 · Cited by 12
Fabrication of monodispersed Taxol-loaded particles using electrohydrodynamic atomization
Ding, L., Lee, T., & Wang, C. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.10.011
Cited by
Alginate gel particles–A review of production techniques and physical properties
Ching, S. H., Bansal, N., & Bhandari, B. (2017) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2014.965773 · Cited by 651
Microfluidic fabrication of microparticles for biomedical applications
Li, W., Zhang, L., Ge, X., Xu, B., Zhang, W., Qu, L., Choi, C.-H., Xu, J., Zhang, A., Lee, H., et al. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00263g · Cited by 585
Microfluidic synthesis of advanced microparticles for encapsulation and controlled release
Duncanson, W. J., Lin, T., Abate, A. R., Seiffert, S., Shah, R. K., & Weitz, D. A. (2012) · Lab on a Chip · doi:10.1039/c2lc21164e · Cited by 370
Drug delivery systems for programmed and on-demand release
Davoodi, P., Lee, L. Y., Xu, Q., Sunil, V., Sun, Y., Soh, S., & Wang, C.-H. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.07.002 · Cited by 353
Shewan, H. M., & Stokes, J. R. (2013) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2013.06.046 · Cited by 352
Metadata
- Authors
- Tran, V.-T., Benoît, J.-P., & Venier-Julienne, M.-C.
- Venue
- International Journal of Pharmaceutics
- Publisher
- Elsevier BV
- Published
- 2011-04
- Volume
- 407
- Issue
- 1-2
- Pages
- 1-11
- ISSN
- 0378-5173 (ISSN-L)
- OpenAlex
- W2082601713
- Cited by
- 188
- References
- 106
- FWCI
- 11.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.