Fabrication of controlled-release budesonide tablets via desktop (FDM) 3D printing
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
The aim of this work was to explore the feasibility of using fused deposition modelling (FDM) 3D printing (3DP) technology with hot melt extrusion (HME) and fluid bed coating to fabricate modified-release budesonide dosage forms. Budesonide was sucessfully loaded into polyvinyl alcohol filaments using HME. The filaments were engineered into capsule-shaped tablets (caplets) containing 9mg budesonide using a FDM 3D printer; the caplets were then overcoated with a layer of enteric polymer. The final printed formulation was tested in a dynamic dissolution bicarbonate buffer system, and two commercial budesonide products, Cortiment® (Uceris®) and Entocort®, were also investigated for comparison. Budesonide release from the Entocort® formulation was rapid in conditions of the upper small intestine while release from the Cortiment® product was more delayed and very slow. In contrast, the new 3D printed caplet formulation started to release in the mid-small intestine but release then continued in a sustained manner throughout the distal intestine and colon. This work has demonstrated the potential of combining FDM 3DP with established pharmaceutical processes, including HME and film coating, to fabricate modified release oral dosage forms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pharmaceutical Applications of Hot-Melt Extrusion: Part I
Crowley, M. M., Zhang, F., Repka, M. A., Thumma, S., Upadhye, S. B., Kumar Battu, S., McGinity, J. W., & Martin, C. (2007) · Drug Development and Industrial Pharmacy · doi:10.1080/03639040701498759 · Cited by 824
Melt extrusion: from process to drug delivery technology
Breitenbach, J. (2002) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(02)00061-9 · Cited by 742
Effect of geometry on drug release from 3D printed tablets
Goyanes, A., Robles Martinez, P., Buanz, A., Basit, A. W., & Gaisford, S. (2015) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2015.04.069 · Cited by 667
Self-citationFused-filament 3D printing (3DP) for fabrication of tablets
Goyanes, A., Buanz, A. B. M., Basit, A. W., & Gaisford, S. (2014) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2014.09.044 · Cited by 587
Self-citationHandbook of Aqueous Solubility Data
Yalkowsky, S. H. (2003) · CRC Press eBooks · doi:10.1201/9780203490396 · Cited by 585
3D printing of modified-release aminosalicylate (4-ASA and 5-ASA) tablets
Goyanes, A., Buanz, A. B. M., Hatton, G. B., Gaisford, S., & Basit, A. W. (2015) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2014.12.003 · Cited by 570
Self-citationSkowyra, J., Pietrzak, K., & Alhnan, M. A. (2015) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2014.11.009 · Cited by 530
Goyanes, A., Wang, J., Buanz, A., Martínez-Pacheco, R., Telford, R., Gaisford, S., & Basit, A. W. (2015) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.5b00510 · Cited by 511
Self-citationOral dosage forms fabricated by Three Dimensional Printing™
Katstra, W. E., Palazzolo, R. D., Rowe, C. W., Giritlioglu, B., Teung, P., & Cima, M. J. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00225-4 · Cited by 334
Multimechanism oral dosage forms fabricated by three dimensional printing™
Rowe, C. W., Katstra, W. E., Palazzolo, R. D., Giritlioglu, B., Teung, P., & Cima, M. J. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00224-2 · Cited by 255
Pharmacokinetics of Budesonide (Entocort??? EC) Capsules for Crohn???s Disease
Edsb??cker, S., & Andersson, T. (2004) · Clinical Pharmacokinetics · doi:10.2165/00003088-200443120-00003 · Cited by 181
Evolution of PVA gels prepared without crosslinking agents as a cell adhesive surface
Gupta, S., Webster, T. J., & Sinha, A. (2011) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-011-4343-2 · Cited by 163
Handbook of aqueous solubility data
(2004) · Choice Reviews Online · doi:10.5860/choice.41-2827 · Cited by 138
Yu, D., Shen, X., Branford-White, C. J., Zhu, L., White, K., & Xiang, Y. (2009) · Journal of Pharmacy and Pharmacology · doi:10.1211/jpp.61.03.0006 · Cited by 128
Liu, F., Merchant, H. A., Kulkarni, R. P., Alkademi, M., & Basit, A. W. (2011) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2011.01.001 · Cited by 124
Self-citationFadda, H. M., Merchant, H. A., Arafat, B. T., & Basit, A. W. (2009) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2009.08.003 · Cited by 123
Self-citationEdsbäcker, S., Bengtsson, B., Larsson, P., Lundin, P., Nilsson, Å., Ulmius, J., & Wollmer, P. (2003) · Alimentary Pharmacology & Therapeutics · doi:10.1046/j.1365-2036.2003.01426.x · Cited by 111
Goyanes, Á., Hatton, G. B., Merchant, H. A., & Basit, A. W. (2015) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2015.02.051 · Cited by 104
Self-citationColonic treatments and targets: issues and opportunities
McConnell, E. L., Liu, F., & Basit, A. W. (2009) · Journal of drug targeting · doi:10.1080/10611860902839502 · Cited by 93
Self-citationProduction of enteric capsules by means of hot-melt extrusion
Mehuys, E., Remon, J., & Vervaet, C. (2004) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2004.10.011 · Cited by 66
Goyanes, Á., Hatton, G. B., & Basit, A. W. (2015) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2014.12.002 · Cited by 29
Self-citationNicholls, A. J., Harris-Collazo, R., Huang, M., Hardiman, Y., Jones, R., & Moro, L. (2013) · Journal of International Medical Research · doi:10.1177/0300060513476588 · Cited by 21
3D printing: the future of manufacturing medicine?
(2015) · Pharmaceutical journal/The pharmaceutical journal · doi:10.1211/pj.2015.20068625 · Cited by 14
The role of Budesonide-MMX in active ulcerative colitis
Gionchetti, P., Praticò, C., Rizzello, F., Calafiore, A., Capozzi, N., Campieri, M., & Calabrese, C. (2014) · Expert Review of Gastroenterology & Hepatology · doi:10.1586/17474124.2014.887437 · Cited by 10
Cited by
Polymers for 3D Printing and Customized Additive Manufacturing
Ligon, S. C., Liska, R., Stampfl, J., Gurr, M., & Mülhaupt, R. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00074 · Cited by 3,741
A new chapter in pharmaceutical manufacturing: 3D-printed drug products
Norman, J., Madurawe, R. D., Moore, C. M. V., Khan, M. A., & Khairuzzaman, A. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.03.001 · Cited by 810
3D Printing in Pharmaceutical and Medical Applications – Recent Achievements and Challenges
Jamróz, W., Szafraniec, J., Kurek, M., & Jachowicz, R. (2018) · Pharmaceutical Research · doi:10.1007/s11095-018-2454-x · Cited by 707
A critical review on the fused deposition modeling of thermoplastic polymer composites
Penumakala, P. K., Santo, J., & Thomas, A. (2020) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2020.108336 · Cited by 704
Stereolithographic (SLA) 3D printing of oral modified-release dosage forms
Wang, J., Goyanes, A., Gaisford, S., & Basit, A. W. (2016) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2016.03.016 · Cited by 612
Self-citation
Metadata
- Authors
- Goyanes, A., Chang, H., Sedough, D., Hatton, G. B., Wang, J., Buanz, A., Gaisford, S., & Basit, A. W.
- Venue
- International Journal of Pharmaceutics
- Publisher
- Elsevier BV
- Published
- 2015-12
- Volume
- 496
- Issue
- 2
- Pages
- 414-420
- ISSN
- 0378-5173 (ISSN-L)
- OpenAlex
- W2156364909
- Cited by
- 330
- References
- 24
- FWCI
- 27.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.