The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Application of perfluoropolyether elastomers in microfluidic drug metabolism assays
Open accessAbstract
Recently, increasing attention has been paid to liver-on-a-chip models for both pharmacokinetics and toxicity (ADMET) screenings. Although polydimethylsiloxane (PDMS) is the most popular material for the fabrication of microfluidic devices, its extensive sorption of hydrophobic drugs limits its applications. Therefore, we investigated a chemically repellent material, perfluoropolyether (PFPE) elastomer, as an alternative to PDMS. Primary rat hepatocytes cultured in the PFPE microfluidic device were polygonal or cuboidal in shape and had one or two prominent nuclei, as when cultured in 96-well plates. When hepatocytes were cultured in the PFPE microfluidic device and exposed to dynamic flow, the production of albumin and urea increased 3.94- and 1.72-fold, respectively, compared with no dynamic flow. Exposure to dynamic flow did not result in obvious changes in the expression of cytochrome P450, but increased the metabolic activity of hepatocytes compared to under static conditions. PFPE devices did not absorb midazolam, which was extensively absorbed by PDMS devices. However, the sorption of bufuralol could not be avoided even with PFPE devices. Solvent swelling experiments highlighted much better chemical repellency with PFPE than with PDMS. Hansen solubility parameters and sphere radius were estimated from the solvent swelling experiments. The relative energy distance (RED) of bufuralol to PFPE was much smaller than that of other three drugs tested, reasonably explaining the high sorption of bufuralol to PFPE. Although sorption into PFPE cannot be completely avoided, PFPE microfluidic devices may provide a better performance in ADMET evaluation than PDMS.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Fluoropolymers and perfluoropolyether oils have not been linked to any adverse effects on humans but have rather improved quality of life and well-being.
“These materials have not been linked to any adverse effects on humans but have rather improved quality of life and well-being.”
From The EU’s Per- and Polyfluoroalkyl Substances (PFAS) Ban: A Case of Policy over Science (2023) · cites this paper as [8]
Citations
Cites
Zanger, U. M., & Schwab, M. (2013) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2012.12.007 · Cited by 4,169
Hansen, C. M. (2007) · CRC Press eBooks · doi:10.1201/9781420006834 · Cited by 3,291
Frank, H. S., & Evans, M. W. (1945) · The Journal of Chemical Physics · doi:10.1063/1.1723985 · Cited by 2,885
PDMS absorption of small molecules and consequences in microfluidic applications
Toepke, M. W., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b612140c · Cited by 1,193
THE ESTIMATION OF HEPATIC BLOOD FLOW IN MAN
Bradley, S. E., Ingelfinger, F. J., Bradley, G. P., & Curry, J. J. (1945) · Journal of Clinical Investigation · doi:10.1172/jci101676 · Cited by 712
Long‐Term in Vitro Function of Adult Hepatocytes in a Collagen Sandwich Configuration
Dunn, J., Tompkins, R. G., & Yarmush, M. L. (1991) · Biotechnology Progress · doi:10.1021/bp00009a007 · Cited by 687
The Universality of the Solubility Parameter
Hansen, C. M. (1969) · Product R&D · doi:10.1021/i360029a002 · Cited by 664
A practical guide to microfluidic perfusion culture of adherent mammalian cells
Kim, L. Y., Toh, Y., Joel Voldman, B., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b704602b · Cited by 466
Kreamer, B. L., Staecker, J. L., Sawada, N., Sattler, G. L., Hsia, M. T. S., & Pitot, H. C. (1986) · In Vitro Cellular & Developmental Biology - Plant · doi:10.1007/bf02623304 · Cited by 383
Tilles, A. W., Baskaran, H., Roy, P., Yarmush, M. L., & Toner, M. (2001) · Biotechnology and Bioengineering · doi:10.1002/bit.1071 · Cited by 326
Campbell, S., Wu, Q., Yazbeck, J., Liu, C., Okhovatian, S., & Radisic, M. (2020) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c00640 · Cited by 316
Beckwitt, C. H., Clark, A. M., Wheeler, S., Taylor, D. L., Stolz, D. B., Griffith, L. G., & Wells, A. H. (2017) · Experimental Cell Research · doi:10.1016/j.yexcr.2017.12.023 · Cited by 215
Leakage-Free Bonding of Porous Membranes into Layered Microfluidic Array Systems
Chueh, B.-H., Huh, D., Kyrtsos, C. R., Houssin, T., Futai, N., & Takayama, S. (2007) · Analytical Chemistry · doi:10.1021/ac062118p · Cited by 208
Microfluidic devices for cell cultivation and proliferation
Tehranirokh, M., Kouzani, A. Z., Francis, P. S., & Kanwar, J. R. (2013) · Biomicrofluidics · doi:10.1063/1.4826935 · Cited by 206
Multi-cellular 3D human primary liver cell culture elevates metabolic activity under fluidic flow
Esch, M. B., Prot, J.-M., Wang, Y. I., Miller, P., Llamas-Vidales, J. R., Naughton, B. A., Applegate, D. R., & Shuler, M. L. (2015) · Lab on a Chip · doi:10.1039/c5lc00237k · Cited by 173
Vinci, B., Duret, C., Klieber, S., Gerbal‐Chaloin, S., Cunha, A. S., Laporte, S., Suc, B., Maurel, P., Ahluwalia, A. D., & Daujat‐Chavanieu, M. (2011) · Biotechnology Journal · doi:10.1002/biot.201000326 · Cited by 116
Hemodynamic flow improves rat hepatocyte morphology, function, and metabolic activity in vitro
Dash, A., Simmers, M. B., Deering, T. G., Berry, D. J., Feaver, R. E., Hastings, N. E., Pruett, T. L., LeCluyse, E. L., Blackman, B. R., & Wamhoff, B. R. (2013) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00331.2012 · Cited by 108
Evaluation of effects of shear stress on hepatocytes by a microchip-based system
Tanaka, Y., Yamato, M., Okano, T., Kitamori, T., & Sato, K. (2006) · Measurement Science and Technology · doi:10.1088/0957-0233/17/12/s08 · Cited by 107
Organ-on-a-chip engineering: Toward bridging the gap between lab and industry
Ramadan, Q., & Zourob, M. M. (2020) · Biomicrofluidics · doi:10.1063/5.0011583 · Cited by 107
The swelling of polymer systems in solvents. II. Mathematics of diffusion
Buckley, D. J., & Berger, M. (1962) · Journal of Polymer Science · doi:10.1002/pol.1962.1205616315 · Cited by 101
Tan, K. Y. S., Keegan, P. M., Rogers, M. T., Lu, M., Gosset, J. R., Charest, J. L., & Bale, S. S. (2019) · Lab on a Chip · doi:10.1039/c8lc01262h · Cited by 78
Extended primary culture of human hepatocytes in a collagen gel sandwich system
Kono, Y., Yang, S., & Roberts, E. A. (1997) · In Vitro Cellular & Developmental Biology - Animal · doi:10.1007/s11626-997-0065-7 · Cited by 66
Bader, A., Frühauf, N. R., Tiedge, M., Drinkgern, M., Bartolo, L. D., Borlak, J. T., Steinhoff, G., & Haverich, A. (1999) · Experimental Cell Research · doi:10.1006/excr.1998.4295 · Cited by 62
Shear stress activation of nuclear receptor PXR in endothelial detoxification
Wang, X., Fang, X., Zhou, J., Chen, Z. B., Zhao, B., Xiao, L., Liu, A., Li, Y.-S. J., Shyy, J. Y.-J., Guan, Y., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1312065110 · Cited by 53
Adhesion of lymphocytes to hepatic endothelium.
Lalor, P. F., & Adams, D. (1999) · Molecular Pathology · doi:10.1136/mp.52.4.214 · Cited by 53
Liu, D., Jiao, S., Wei, J., Zhang, X., Pei, Y., Pei, Z., Li, J., & Du, Y. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.119669 · Cited by 48
Jellali, R., Bricks, T., Jacques, S., Fleury, M., Paullier, P., Merlier, F., & Leclerc, É. (2016) · Biopharmaceutics & Drug Disposition · doi:10.1002/bdd.2010 · Cited by 47
Devaraju, N. S. G. K., & Unger, M. (2011) · Lab on a Chip · doi:10.1039/c0lc00274g · Cited by 40
Gilglioni, E. H., Chang, J., Duijst, S., Go, S., Adam, A. A. A., Hoekstra, R., Verhoeven, A. J., Ishii‐Iwamoto, E. L., & Elferink, R. P. J. O. (2018) · Hepatology Communications · doi:10.1002/hep4.1140 · Cited by 39
Enhanced Oxygen Availability Improves Liver‐specific Functions of the AMC Bioartificial Liver
Poyck, P. P. C., Mareels, G., Hoekstra, R., van Wijk, A. C. W. A., van der Hoeven, T. V., van Gulik, T. M., Verdonck, P., & Chamuleau, R. A. F. M. (2007) · Artificial Organs · doi:10.1111/j.1525-1594.2007.00500.x · Cited by 29
Baudoin, R., Alberto, G., Legendre, A., Paullier, P., Naudot, M., Fleury, M., Jacques, S., Griscom, L., & Leclerc, É. (2013) · Biotechnology Progress · doi:10.1002/btpr.1857 · Cited by 27
Duivenvoorde, L. P. M., Louisse, J., Pinckaers, N. E. T., Nguyen, T., & van der Zande, M. (2021) · Scientific Reports · doi:10.1038/s41598-021-89710-6 · Cited by 26
Burton, L., Scaife, P. J., Paine, S. W., Mellor, H. R., Abernethy, L., Littlewood, P., & Rauch, C. (2020) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00472.2019 · Cited by 13
The swelling of polymer solvents. III. Sorption of liquids by elastomers
Buckley, D. J., & Berger, M. (1962) · Journal of Polymer Science · doi:10.1002/pol.1962.1205816671 · Cited by 1
Flagged first, then by citations
Cited by
Sorted by citations
Yang, J., Hirai, Y., Iida, K., Ito, S., Trumm, M., Terada, S., Sakai, R., Tsuchiya, T., Tabata, O., & Kamei, K.-I. (2023) · Communications Biology · doi:10.1038/s42003-023-04710-8 · Cited by 98
The EU’s Per- and Polyfluoroalkyl Substances (PFAS) Ban: A Case of Policy over Science
Spyrakis, F., & Dragani, T. A. (2023) · Toxics · doi:10.3390/toxics11090721 · Cited by 78
Wang, M., Sasaki, Y., Sakagami, R., Minamikawa, T., Tsuda, M., Ueno, R., Deguchi, S., Negoro, R., So, K., Higuchi, Y., et al. (2024) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.4c00605 · Cited by 20
Recent Advances in the Gastrointestinal Complex in Vitro Model for ADME Studies
Michiba, K., Watanabe, K., Imaoka, T., & Nakai, D. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics16010037 · Cited by 17
Negoro, R., Deguchi, S., Yamazaki, D., Takayama, K., & Fujita, T. (2025) · Scientific Reports · doi:10.1038/s41598-025-22425-0 · Cited by 10
Organoids and microphysiological systems for pharmaceutical research of viral respiratory infections
Deguchi, S., Yokoi, F., & Takayama, K. (2024) · Drug Metabolism and Pharmacokinetics · doi:10.1016/j.dmpk.2024.101041 · Cited by 7
In situ formation and culture of cell spheroids in a low-binding 3D-printed biochip
Martins, A., Klieber, S., Graët, C. L., Leclerc, É., Legallais, C., & Jellali, R. (2025) · Lab on a Chip · doi:10.1039/d5lc00503e · Cited by 4
Iwao, T., & Matsunaga, T. (2024) · Drug Metabolism and Pharmacokinetics · doi:10.1016/j.dmpk.2024.101045 · Cited by 5
Bai, Y., Hu, X., Zhang, M., Yu, Q., Liang, Y., Wu, Y. B., Cai, M., Zhou, F., & Liu, W. (2025) · Friction · doi:10.26599/frict.2025.9441094 · Cited by 3
Wang, M., Zhang, Q., Aoki, K., Higuchi, Y., & Yamashita, F. (2025) · Toxicology Letters · doi:10.1016/j.toxlet.2025.03.004 · Cited by 1
Metadata
- Authors
- Wang, M., Tsuda, M., Deguchi, S., Higuchi, Y., So, K., Torisawa, Y.-S., Takayama, K., & Yamashita, F.
- Affiliations
- Kyoto University (JP)
- Corresponding author
- Yamashita, Fumiyoshi
- Venue
- International Journal of Pharmaceutics
- Publisher
- Elsevier BV
- Published
- 2022-11
- Volume
- 627
- Pages
- 122253
- ISSN
- 0378-5173 (ISSN-L)
- OpenAlex
- W4297963427
- Cited by
- 10
- References
- 34
- Citations by year
- 2025: 4 · 2024: 3 · 2023: 3
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- www.elsevier.com/open-access/userlicense/1.0/ (am, 332 d)
- doi.org/10.15223/policy-017 (stm-asf)
- doi.org/10.15223/policy-037 (stm-asf)
- doi.org/10.15223/policy-012 (stm-asf)
- doi.org/10.15223/policy-029 (stm-asf)
- doi.org/10.15223/policy-004 (stm-asf)
- Locations
- International Journal of Pharmaceutics (acceptedVersion)
- PubMed (publishedVersion)
- Funders
- Japan Agency for Medical Research and Development (jp21be0304202h0005)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- liver-on-a-chip, hepatocyte culture, drug sorption, solvent swelling, Hansen solubility parameters, bufuralol, midazolam, cytochrome P450 expression, ADMET screening
- MeSH terms
- Albumins, Animals, Dimethylpolysiloxanes, Ethers, Fluorocarbons, Midazolam, Solvents, Urea, Elastomers, Microfluidics, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review