Cited by 6Heat Transfer and OptimizationRefrigeration and Air Conditioning TechnologiesIcing and De-icing Technologies

Study on heat and mass transfer characteristics of humid air-flow in a fin bundle

Kim, Dong-Hwi, Koyama, Shigeru, Kuwahara, Ken, Kwon, Jeong-Tae, Park, Byung-Duck·2010·International Journal of Refrigeration

Integrity signals

Registry

Crossref · 10.1016/j.ijrefrig.2010.05.013

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • On a set of flat fins with 11 rows under constant air flow rate, the difference in frost distribution along air flow direction is significant, and the minimum and maximum values of frost thickness appear at the second and eighth rows, respectively.

    “Their results showed that the difference in frost distribution along air flow direction was significant, and the minimum and maximum values of frost thickness appeared at the second and eighth rows, respectively.”
  • The air flow field may have a significant effect on the frosting behaviors on set of fins.

    “Therefore, it can be concluded that the air flow field may have a significant effect on the frosting behaviors on set of fins.”

Cites

Flagged first, then by citations

Authors
Kim, D.-H., Koyama, S., Kuwahara, K., Kwon, J.-T., & Park, B.-D.
Affiliations
  • LG (South Korea) (KR)
  • Kyushu University (JP)
  • Hoseo University (KR)
  • Kyungpook National University (KR)
Corresponding author
Kwon, Jeong-Tae
Venue
International Journal of Refrigeration
Publisher
Elsevier BV
Published
2010-11
Volume
33
Issue
7
Pages
1434-1443
ISSN
0140-7007 (ISSN-L)
OpenAlex
W2035012146
Cited by
6
References
5
Citations by year
2025: 1 · 2022: 1 · 2021: 1 · 2019: 1 · 2018: 1 · 2013: 1
FWCI
0.58
Type
journal article
Language
en
Open access
closed
Locations
International Journal of Refrigeration (publishedVersion)
Funders
Korea Science and Engineering Foundation
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
Keywords
frost formation, heat and mass transfer, pressure drop, air humidity, air velocity, heat exchanger fins

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review