Deep Learning Algorithm for Auto-Delineation of High-Risk Oropharyngeal Clinical Target Volumes With Built-In Dice Similarity Coefficient Parameter Optimization Function
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Purpose: Automating and standardizing the contouring of clinical target volumes (CTVs) can reduce inter-physician variability which is one of the largest sources of uncertainty in head and neck radiotherapy. Besides using uniform margin expansions to auto-delineate high-risk CTVs, very little work has been done to provide patient and disease specific high-risk CTVs. The aim of this study is to develop a deep neural network for the auto-delineation of high-risk CTVs. Methods and Materials: Fifty-two oropharyngeal cancer patients were selected for this study. All patients were treated at The University of Texas Cancer from January 2006 to August 2010 and had previously contoured gross tumor volume and CTVs. We developed a deep learning algorithm using deep auto-encoders to identify physician contouring patterns at our institution. These models use distance maps information from surrounding anatomical structures and the gross tumor volume as input parameters and conduct voxel-based classification to identify voxels that are part of the high-risk CTV. In addition, we developed a novel probability threshold selection function, based on the Dice Similarity Coefficient (DSC), to improve the generalization of the predicted volumes. The DSC-based function is implemented during an inner cross-validation loop and probability thresholds are selected a priori during model parameter optimization. Volumetric comparison between the predicted and manually contoured volumes was performed to assess our model. Results: The predicted volumes had median DSC values of 0.81 (range: 0.62–0.90), median mean surface distance of 2.8 mm (range: 1.6–5.5 mm), and median 95th Hausdorff distance of 7.5 mm (range: 4.7–17.9 mm) when comparing our predicted high-risk CTV volumes with physician manual contours. Conclusion: These predicted high-risk CTVs provide close agreement to the ground-truth when compared to current inter-observer variability. The predicted contours could be implemented clinically with only minor or no changes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Greedy layer-wise training of deep networks
Bengio, Y., Lamblin, P., Popovici, D., & Larochelle, H. (2007) · Advances in Neural Information Processing Systems 19 · doi:10.7551/mitpress/7503.003.0024 · Cited by 4,841
Sparse coding with an overcomplete basis set: A strategy employed by V1?
Olshausen, B. A., & Field, D. J. (1997) · Vision Research · doi:10.1016/s0042-6989(97)00169-7 · Cited by 3,642
Cited by
Artificial intelligence in radiation oncology
Huynh, E., Hosny, A., Guthier, C., Bitterman, D. S., Petit, S. F., Haas-Kogan, D. A., Kann, B., Aerts, H. J. W. L., & Mak, R. H. (2020) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-020-0417-8 · Cited by 419
Cardenas, C. E., Yang, J., Anderson, B. M., Court, L. E., & Brock, K. B. (2019) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2019.02.001 · Cited by 407
Self-citationSurvey on deep learning for radiotherapy
Meyer, P., Noblet, V., Mazzara, C., & Lallement, A. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.05.018 · Cited by 302
Applications and limitations of machine learning in radiation oncology
Jarrett, D., Stride, E., Vallis, K., & Gooding, M. J. (2019) · The British Journal of Radiology · doi:10.1259/bjr.20190001 · Cited by 164
Syed, M., Flechsig, P., Liermann, J., Windisch, P., Staudinger, F., Akbaba, S., Koerber, S. A., Freudlsperger, C., Plinkert, P. K., Debus, J., et al. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-04859-y · Cited by 164
“Deficiency in reproducibility and inconsistency of manual target volume delineation has direct consequences for tumour recurrence [17].”
BackgroundArtificial intelligence in radiotherapy
Li, G., Wu, X., & Ma, X. (2022) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2022.08.005 · Cited by 46
Rokhshad, R., Salehi, S. N., Yavari, A., Shobeiri, P., Esmaeili, M., Manila, N., Motamedian, S. R., & Mohammad-Rahimi, H. (2024) · Oral Radiology · doi:10.1007/s11282-023-00715-5 · Cited by 23
Metadata
- Authors
- Cardenas, C. E., McCarroll, R. E., Court, L. E., Elgohari, B. A., Elhalawani, H., Fuller, C. D., Kamal, M. J., Meheissen, M. A. M., Mohamed, A. S. R., Rao, A., Williams, B., Wong, A., Yang, J., & Aristophanous, M.
- Venue
- International Journal of Radiation Oncology*Biology*Physics
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 101
- Issue
- 2
- Pages
- 468-478
- ISSN
- 0360-3016 (ISSN-L)
- OpenAlex
- W2790751088
- Cited by
- 150
- References
- 2
- FWCI
- 15.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.