Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 164

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Applications and limitations of machine learning in radiation oncology

Open access
Jarrett, Daniel, Stride, Eleanor, Vallis, Katherine, Gooding, Mark J. · 2019 · The British Journal of Radiology

Abstract

Machine learning approaches to problem-solving are growing rapidly within healthcare, and radiation oncology is no exception. With the burgeoning interest in machine learning comes the significant risk of misaligned expectations as to what it can and cannot accomplish. This paper evaluates the role of machine learning and the problems it solves within the context of current clinical challenges in radiation oncology. The role of learning algorithms within the workflow for external beam radiation therapy are surveyed, considering simulation imaging, multimodal fusion, image segmentation, treatment planning, quality assurance, and treatment delivery and adaptation. For each aspect, the clinical challenges faced, the learning algorithms proposed, and the successes and limitations of various approaches are analyzed. It is observed that machine learning has largely thrived on reproducibly mimicking conventional human-driven solutions with more efficiency and consistency. On the other hand, since algorithms are generally trained using expert opinion as ground truth, machine learning is of limited utility where problems or ground truths are not well-defined, or if suitable measures of correctness are not available. As a result, machines may excel at replicating, automating and standardizing human behaviour on manual chores, meanwhile the conceptual clinical challenges relating to definition, evaluation, and judgement remain in the realm of human intelligence and insight.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1259/bjr.20190001

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Research works printed but not linked: 81

  1. Feng, 2018, Machine learning in radiation oncology: opportunities, requirements, and needs, Frontiers in Oncology, 8, 10.3389/fonc.2018.00110 · DOI
  2. Lustberg, 2017, Big data in radiation therapy: challenges and opportunities, Br J Radiol, 90, 20160689, 10.1259/bjr.20160689 · DOI
  3. Thompson, 2018, Artificial intelligence in radiation oncology: a specialty-wide disruptive transformation?, Radiotherapy and Oncology, 129, 421, 10.1016/j.radonc.2018.05.030 · DOI · Paper page
  4. Naqa, 2015, Machine Learning in Radiation Oncology, 10.1007/978-3-319-18305-3 · DOI · Paper page
  5. Aird, 2002, CT simulation for radiotherapy treatment planning, Br J Radiol, 75, 937, 10.1259/bjr.75.900.750937 · DOI
  6. van Herk, 2004, Errors and margins in radiotherapy, Semin Radiat Oncol, 14, 52, 10.1053/j.semradonc.2003.10.003 · doi:10.1053/j.semradonc.2003.10.003
  7. Murphy, 2007, The management of imaging dose during image-guided radiotherapy, Medical Physics, 34, 4041, 10.1118/1.2775667 · doi:10.1118/1.2775667
  8. Willemink, 2018, The evolution of image reconstruction for CT-from filtered back projection to artificial intelligence, European Radiology
  9. Kang, 2017, A deep convolutional neural network using directional wavelets for low-dose X-ray CT reconstruction, Med Phys, 44, e360, 10.1002/mp.12344 · DOI · Paper page
  10. Wu, 2017, Iterative low-dose CT reconstruction with priors trained by artificial neural network, IEEE Trans Med Imaging, 36, 2479, 10.1109/TMI.2017.2753138 · DOI · Paper page
  11. Chen, 2017, Low-dose CT with a residual encoder-decoder convolutional neural network, IEEE Trans Med Imaging, 36, 2524, 10.1109/TMI.2017.2715284 · DOI · Paper page
  12. Chen, 2017, Discriminative Prior - Prior Image Constrained Compressed Sensing Reconstruction for Low-Dose CT Imaging, Sci Rep, 7, 13868, 10.1038/s41598-017-13520-y · DOI
  13. Gjesteby, Deep learning methods to guide CT image reconstruction and reduce metal artifacts, In Medical Imaging 2017: Physics of Medical Imaging; 2017: International Society for Optics and Photonics. p, 101322W
  14. Zhang, 2018, Convolutional neural network based metal artifact reduction in X-ray computed tomography, IEEE Trans Med Imaging, 37, 1370, 10.1109/TMI.2018.2823083 · DOI · Paper page
  15. Nie, 2017, Medical image synthesis with context-aware generative adversarial networks, In International Conference on Medical Image Computing and Computer-Assisted Intervention, 417
  16. Guerreiro, 2017, Evaluation of a multi-atlas CT synthesis approach for MRI-only radiotherapy treatment planning, Phys Med, 35, 7, 10.1016/j.ejmp.2017.02.017 · DOI
  17. Han, 2017, MR-based synthetic CT generation using a deep convolutional neural network method, Med Phys, 44, 1408, 10.1002/mp.12155 · DOI · Paper page
  18. Jang, 2018, Technical note: deep learning based MRAC using rapid ultrashort echo time imaging, Medical Physics, 45, 3697, 10.1002/mp.12964 · DOI · Paper page
  19. Maspero, 2018, Dose evaluation of fast synthetic-CT generation using a generative adversarial network for general pelvis MR-only radiotherapy, Phys Med Biol, 63, 185001, 10.1088/1361-6560/aada6d · DOI · Paper page
  20. Wolterink, 2017, Deep Mr to CT synthesis using upaired data, In Internation Workhop on Simulation and Synthesis in Medical Imaging, 14
  21. Tyagi, 2017, Dosimetric and workflow evaluation of first commercial synthetic CT software for clinical use in pelvis, Phys Med Biol, 62, 2961, 10.1088/1361-6560/aa5452 · doi:10.1088/1361-6560/aa5452
  22. Kessler, 2006, Image registration and data fusion in radiation therapy, Br J Radiol, 79 Spec No 1, S99, 10.1259/bjr/70617164 · DOI · Paper page
  23. Nix, 2017, Automated, reference-free local error assessment of multimodal deformable image registration for radiotherapy in the head and neck, Radiother Oncol, 125, 478, 10.1016/j.radonc.2017.10.004 · DOI
  24. Kierkels, 2018, An automated, quantitative, and case-specific evaluation of deformable image registration in computed tomography images, Phys Med Biol, 63, 045026, 10.1088/1361-6560/aa9dc2 · DOI
  25. Veiga, 2015, Toward adaptive radiotherapy for head and neck patients: uncertainties in dose warping due to the choice of deformable registration algorithm, Med Phys, 42, 760, 10.1118/1.4905050 · DOI
  26. Cao, 2016, Learning-Based multimodal image registration for prostate cancer radiation therapy, International Conference on Medical Image Computing and Computer-Assisted Intervention, 1
  27. Kearney, 2018, An unsupervised convolutional neural network-based algorithm for deformable image registration, Phys Med Biol, 63, 185017, 10.1088/1361-6560/aada66 · DOI
  28. Lee, 2009, Learning similarity measure for multi-modal 3D image registration, In Conference on Computer Vision and Pattern Recognition, 186
  29. Michel, 2011, Boosted metric learning for 3D multi-modal deformable registration, In IEEE International Symposium on Biomedical Imaging, 1209
  30. Simonovsky, 2016, Komodakis N. a deep metric for multimodal registration, In International Conference On Medical Image Computing & Computer Assisted Intervention
  31. Cheng, 2018, Deep similarity learning for multimodal medical images, Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization, 6, 248
  32. Oktay, 2015, Structured decision forests for multi-modal ultrasound image registration, International Conference on Medical Image Computing and Computer-Assisted Intervention, 363
  33. Liao, 2017, An Artificial agent for robust image registration, Proceedings of the Thirty-First AAAI Conference on Artificial Intelligence, 4168
  34. Olsen, 2007, Now you see it… imaging in radiotherapy treatment planning and delivery, Radiotherapy and Oncology, 85, 173, 10.1016/j.radonc.2007.11.001 · doi:10.1016/j.radonc.2007.11.001
  35. Roques, 2014, Patient selection and radiotherapy volume definition — can we improve the weakest links in the treatment chain?, Clinical Oncology, 26, 353, 10.1016/j.clon.2014.02.013 · doi:10.1016/j.clon.2014.02.013
  36. Njeh, 2008, Tumor delineation: the weakest link in the search for accuracy in radiotherapy, Journal of Medical Physics, 33, 136, 10.4103/0971-6203.44472 · doi:10.4103/0971-6203.44472
  37. Sharp, 2014, Vision 20/20: perspectives on automated image segmentation for radiotherapy, Medical Physics, 41, 050902, 10.1118/1.4871620 · DOI · Paper page
  38. Peressutti, 2016, TU-AB-202-10: how effective are current atlas selection methods for atlas-based Auto-Contouring in radiotherapy planning?, Medical Physics, 43, 3738, 10.1118/1.4957432 · doi:10.1118/1.4957432
  39. Dolz, 2015, Supervised machine learning based classification scheme to segment the brainstem on MRI in Muilticenter brain tumor treatment context, Hyper Articles en Ligne
  40. Pinto, 2015, 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
  41. Lustberg, 2018, Clinical evaluation of atlas and deep learning based automatic contouring for lung cancer, Radiotherapy and Oncology, 126, 312, 10.1016/j.radonc.2017.11.012 · DOI · Paper page
  42. Guo, 2016, Deformable Mr prostate segmentation via deep feature learning and sparse patch matching, IEEE Trans Med Imaging, 35, 1077, 10.1109/TMI.2015.2508280 · DOI · Paper page
  43. Fechter, 2017, Esophagus segmentation in CT via 3D fully convolutional neural network and random walk, Med Phys, 44, 6341, 10.1002/mp.12593 · DOI
  44. Bobo, 2018, Fully Convolutional Neural Networks Improve Abdominal Organ Segmentation
  45. Men, 2018, Fully automatic and robust segmentation of the clinical target volume for radiotherapy of breast cancer using big data and deep learning, Phys Med, 50, 13, 10.1016/j.ejmp.2018.05.006 · DOI · Paper page
  46. Cardenas, 2018, Deep learning algorithm for Auto-Delineation of high-risk oropharyngeal clinical target volumes with built-in dice similarity Coefficient parameter optimization function. International Journal of Radiation oncology, biology, Physics, 101, 468
  47. Men, 2017, Automatic segmentation of the clinical target volume and organs at risk in the planning CT for rectal cancer using deep dilated convolutional neural networks, Med Phys, 44, 6377, 10.1002/mp.12602 · DOI · Paper page
  48. Craft, 2006, Approximating convex Pareto surfaces in multiobjective radiotherapy planning, Med. Phys., 33, 3399, 10.1118/1.2335486 · doi:10.1118/1.2335486
  49. Monz, 2008, Pareto navigation: algorithmic Foundation of interactive multi-criteria IMRT planning, Phys Med Biol, 53, 985, 10.1088/0031-9155/53/4/011 · DOI
  50. Hazell, 2016, Automatic planning of head and neck treatment plans, J Appl Clin Med Phys, 17, 272, 10.1120/jacmp.v17i1.5901 · doi:10.1120/jacmp.v17i1.5901
  51. Gallio, 2018, Evaluation of a commercial automatic treatment planning system for liver stereotactic body radiation therapy treatments, Physica Medica, 46, 153, 10.1016/j.ejmp.2018.01.016 · doi:10.1016/j.ejmp.2018.01.016
  52. Shiraishi, 2015, Knowledge-based prediction of plan quality metrics in intracranial stereotactic radiosurgery, Med Phys, 42, 908, 10.1118/1.4906183 · doi:10.1118/1.4906183
  53. McIntosh, 2017, Fully automated treatment planning for head and neck radiotherapy using a voxel-based dose prediction and dose mimicking method, Phys. Med. Biol., 62, 5926, 10.1088/1361-6560/aa71f8 · DOI · Paper page
  54. Valdes, 2017, Clinical decision support of radiotherapy treatment planning: a data-driven machine learning strategy for patient-specific dosimetric decision making, Radiother Oncol, 125, 392, 10.1016/j.radonc.2017.10.014 · DOI
  55. Chanyavanich, 2011, Knowledge-based IMRT treatment planning for prostate cancer, Med Phys, 38, 2515, 10.1118/1.3574874 · DOI · Paper page
  56. Kusters, 2017, Automated IMRT planning in pinnacle, Strahlenther Onkol, 193, 1031, 10.1007/s00066-017-1187-9 · doi:10.1007/s00066-017-1187-9
  57. Wang, 2017, Is it possible for knowledge-based planning to improve intensity modulated radiation therapy plan quality for planners with different planning experiences in left-sided breast cancer patients?, Radiation Oncology, 12, 10.1186/s13014-017-0822-z · DOI
  58. Nguyen, 2019, A feasibility study for predicting optimal radiation therapy dose distributions of prostate cancer patients from patient anatomy using deep learning, Sci Rep, 9, 1076, 10.1038/s41598-018-37741-x · DOI · Paper page
  59. Shiraishi, 2016, Knowledge-based prediction of three-dimensional dose distributions for external beam radiotherapy, Med Phys, 43, 378, 10.1118/1.4938583 · DOI · Paper page
  60. Ziemer, 2017, Fully automated, comprehensive knowledge-based planning for stereotactic radiosurgery: preclinical validation through blinded physician review, Pract Radiat Oncol, 7, e569, 10.1016/j.prro.2017.04.011 · doi:10.1016/j.prro.2017.04.011
  61. Mardani, 2016, Deep-Learning based prediction of achievable dose for Personalizing inverse treatment planning. International Journal of Radiation oncology, biology, Physics, 96
  62. Mahmood, 2018, Automated treatment planning in radiation therapy using generative Adversarial networks, Proceedings of Machine Learning Research: Machine Learning for Healthcare, 85
  63. McIntosh, 2013, Groupwise conditional random forests for automatic shape classification and contour quality assessment in radiotherapy planning, IEEE Trans Med Imaging, 32, 1043, 10.1109/TMI.2013.2251421 · DOI
  64. Naqa, 2011, An anomaly detector for radiotherapy quality assurance using machine learning, Medical Physics, 38
  65. Tol, 2015, Can knowledge-based DVH predictions be used for automated, individualized quality assurance of radiotherapy treatment plans? Radiation Oncology, 10
  66. Stanhope, 2015, Utilizing knowledge from prior plans in the evaluation of quality assurance, Phys Med Biol, 60, 4873, 10.1088/0031-9155/60/12/4873 · doi:10.1088/0031-9155/60/12/4873
  67. Gits, 2016, Using a knowledge-based planning model for quality assurance of liver stereotactic body radiation therapy plans. International Journal of Radiation oncology, biology, Physics, 96
  68. Carlson, 2016, A machine learning approach to the accurate prediction of multi-leaf collimator positional errors, Phys Med Biol, 61, 2514, 10.1088/0031-9155/61/6/2514 · DOI
  69. Interian, 2018, Deep nets vs expert designed features in medical physics: an IMRT QA case study, Medical Physics, 45, 2672, 10.1002/mp.12890 · DOI
  70. Valdes, 2017, IMRT QA using machine learning: a multi-institutional validation, J Appl Clin Med Phys, 18, 279, 10.1002/acm2.12161 · DOI · Paper page
  71. Nelms, 2011, Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors, Medical Physics, 38, 1037, 10.1118/1.3544657 · doi:10.1118/1.3544657
  72. Kida, 2018, Cone beam computed tomography image quality improvement using a deep Convolutional neural network, Cureus, 10, e2548
  73. Kurz, 2018, OA127] Cone-beam CT intensity correction for adaptive radiotherapy of the prostate using deep learning, Physica Medica, 52, 48, 10.1016/j.ejmp.2018.06.199 · doi:10.1016/j.ejmp.2018.06.199
  74. Murphy, 2015, Machine Learning in Radiation Oncology, 203, 10.1007/978-3-319-18305-3_11 · doi:10.1007/978-3-319-18305-3_11
  75. Tatinati, 2016, Ensemble framework based real-time respiratory motion prediction for adaptive radiotherapy applications, Medical Engineering & Physics, 38, 749, 10.1016/j.medengphy.2016.04.021 · DOI
  76. Zarepisheh, 2014, A DVH-guided IMRT optimization algorithm for automatic treatment planning and adaptive radiotherapy replanning, Medical Physics, 41, 061711, 10.1118/1.4875700 · DOI
  77. El Naqa, 2016, Reinforcement learning strategies for decision making in knowledge-based adaptive radiation therapy: application in liver cancer, International Journal of Radiation Oncology*Biology*Physics, 96, S45, 10.1016/j.ijrobp.2016.06.119 · DOI
  78. Tseng, 2018, The role of machine learning in knowledge-based Response-Adapted radiotherapy, Frontiers in Oncology, 8, 10.3389/fonc.2018.00266 · DOI
  79. Tseng, 2017, Deep reinforcement learning for automated radiation adaptation in lung cancer, Medical Physics, 44, 6690, 10.1002/mp.12625 · DOI · Paper page
  80. Guidi, 2017, Expert system classifier for adaptive radiation therapy in prostate cancer, Australas Phys Eng Sci Med, 40, 337, 10.1007/s13246-017-0535-5 · doi:10.1007/s13246-017-0535-5
  81. Guidi, 2016, A machine learning tool for re-planning and adaptive RT: a multicenter cohort investigation, Physica Medica, 32, 1659, 10.1016/j.ejmp.2016.10.005 · DOI

Cited by

See all 164

Metadata

Authors
Jarrett, D., Stride, E., Vallis, K., & Gooding, M. J.
Venue
The British Journal of Radiology
Published
2019-06-05
Volume
92
Issue
1100
Pages
20190001-20190001
ISSN
  • 0007-1285 (ISSN-L)
  • 1748-880X
OpenAlex
W2944958482
Cited by
164
References
12
FWCI
18.73
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Applications and limitations of machine learning in radiation oncology. https://app.cochat.ai/papers/10.1259/bjr.20190001
The paper
Jarrett, D., Stride, E., Vallis, K., & Gooding, M. J. (2019). Applications and limitations of machine learning in radiation oncology. The British Journal of Radiology. https://doi.org/10.1259/bjr.20190001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.