The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Smart implants in fracture care – Only buzzword or real opportunity
Open accessAbstract
The assessment of fracture healing is still marked by a subjective and diffuse outcome due to the lack of clinically available quantitative measures. Without reliable information on the progression of healing and uniform criteria for union and non-union, therapeutic decision making, e.g. regarding the allowed weight bearing, hinges on the experience and the subjective evaluation of physicians. Already decades ago, fracture stiffness has been identified as a valid outcome measure for the maturity of the repair tissue. Despite early promising results, so far no method has made its way into practice beyond clinical studies. However, with current technological advancements and a general trend towards digital health care, measuring fracture healing seems to regain momentum. New generations of instrumented implants with sensoring capabilities, often termed as "smart implants", are under development. They target X-ray free and timely provision of reliable feedback upon the mechanical competence of the repair tissue and the healing environment to support therapeutic decision making and individualized after-care. With the gained experience from these devices, the next generations of smart implants may become increasingly sophisticated by internally analyzing the measured data and suggesting adequate therapeutic actions on their own.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Perren, S. M. (2002) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.84b8.13752 · Cited by 1,252
EVOLUTION OF THE INTERNAL FIXATION OF LONG BONE FRACTURES
Perren, S. M. (2002) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.84b8.0841093 · Cited by 921
Whelan, D. B., Bhandari, M., Stephen, D., Kreder, H., McKee, M. D., Zdero, R., & Schemitsch, E. H. (2010) · Journal of Trauma: Injury, Infection & Critical Care · doi:10.1097/ta.0b013e3181a7c16d · Cited by 428
A Lack of Consensus in the Assessment of Fracture Healing Among Orthopaedic Surgeons
Bhandari, M., Guyatt, G. H., Swiontkowski, M. F., et al. (2002) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-200209000-00004 · Cited by 325
Ekegren, C. L., Edwards, E. R., de Steiger, R. N., & Gabbe, B. J. (2018) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph15122845 · Cited by 307
The initial phase of fracture healing is specifically sensitive to mechanical conditions
Klein, P., Schell, H., Streitparth, F., et al. (2003) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(02)00259-0 · Cited by 273
Henderson, C. E., Lujan, T. J., Kuhl, L. L., et al. (2011) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-011-1870-6 · Cited by 232
Measuring stiffness can define healing of tibial fractures
Richardson, J., Cunningham, J. L., Goodship, A. E., O’Connor, B. G., & KENWRIGHT, J. (1994) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.76b3.8175839 · Cited by 202
Revolution in plate osteosynthesis: new internal fixator systems
Schütz, M. A., & Südkamp, N. P. (2003) · Journal of Orthopaedic Science · doi:10.1007/s007760300044 · Cited by 173
Smart implants in orthopedic surgery, improving patient outcomes: a review
Ledet, E. H., Liddle, B., Kradinova, K., & Harper, S. (2018) · Innovation and Entrepreneurship in Health · doi:10.2147/ieh.s133518 · Cited by 156
When Is a Fracture Healed? Radiographic and Clinical Criteria Revisited
Dijkman, B. G., Sprague, S., Schemitsch, E. H., & Bhandari, M. (2010) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0b013e3181ca3f97 · Cited by 140
Monitoring and healing analysis of 100 tibial shaft fractures
Claes, L., Grass, R., Schmickal, T., Kisse, B., Eggers, C., Gerngro�, H., Mutschler, W., Arand, M., Wintermeyer, T., & Wentzensen, A. (2002) · Langenbeck s Archives of Surgery · doi:10.1007/s00423-002-0306-x · Cited by 137
Concept, design and fabrication of smart orthopedic implants
Burny, F., Donkerwolcke, M., Moulart, F., Bourgois, R., Puers, R., Schuylenbergh, K. V., Barbosa, M. A., Paiva, O. C., Rodes, F., Bégueret, J.-B., et al. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00062-x · Cited by 125
Reliability of radiographs in defining union of internally fixed fractures
Davis, B. J., Roberts, P. J., Moorcroft, C. I., et al. (2003) · Injury · doi:10.1016/s0020-1383(03)00262-6 · Cited by 108
Fracture Healing Assessment Comparing Stiffness Measurements using Radiographs
McClelland, D., Thomas, P. B. M., Bancroft, G. A., et al. (2006) · Clinical Orthopaedics and Related Research · doi:10.1097/blo.0b013e31802f80a8 · Cited by 93
McGilvray, K. C., Unal, E., Troyer, K. L., Santoni, B. G., Palmer, R. H., Easley, J. T., Demir, H. V., & Puttlitz, C. M. (2015) · Journal of Orthopaedic Research® · doi:10.1002/jor.22918 · Cited by 74
Quantification of Fracture Healing from Radiographs Using the Maximum Callus Index
Eastaugh-Waring, S. J., Joslin, C. C., Hardy, J. R. W., et al. (2009) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-009-0775-0 · Cited by 73
Radiographic union score for hip substantially improves agreement between surgeons and radiologists
Bhandari, M., Chiavaras, M. M., Parasu, N., et al. (2013) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-14-70 · Cited by 72
Twenty Years Experience in Fracture Healing Measurement with Strain Gauges
Burny, F., Donkerwolcke, M., Bourgois, R., et al. (1984) · Orthopedics · doi:10.3928/0147-7447-19841201-08 · Cited by 67
Consigliere, P., Iliopoulos, E., Ads, T., et al. (2019) · European Journal of Orthopaedic Surgery & Traumatology · doi:10.1007/s00590-019-02486-4 · Cited by 66
Fracture stiffness measurement in the assessment and management of tibial fractures
Richardson, J., KENWRIGHT, J., & Cunningham, J. L. (1992) · Clinical Biomechanics · doi:10.1016/0268-0033(92)90018-y · Cited by 62
Design and performance of a fracture monitoring transducer
Evans, M., KENWRIGHT, J., & Cunningham, J. L. (1988) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(88)90028-3 · Cited by 60
Zou, J., Zhang, W., & Zhang, C. (2013) · Injury · doi:10.1016/j.injury.2013.02.006 · Cited by 57
Telemetric assessment of bone healing with an instrumented internal fixator
Seide, K., Aljudaibi, M., Weinrich, N., Kowald, B., Jürgens, C., Müller, J. W., & Faschingbauer, M. (2012) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.94b3.27550 · Cited by 51
An electronically instrumented internal fixator for the assessment of bone healing
Kienast, B. J., Kowald, B., Seide, K., et al. (2016) · Bone and Joint Research · doi:10.1302/2046-3758.55.2000611 · Cited by 36
Müller, C. W., Pfeifer, R., Meier, K., Decker, S., Reifenrath, J., Gösling, T., Wesling, V., Krettek, C., Hurschler, C., & Ferle, M. (2015) · BioMed Research International · doi:10.1155/2015/652940 · Cited by 30
An implanted pH sensor read using radiography
Arifuzzaman, M., Millhouse, P. W., Raval, Y. S., et al. (2019) · The Analyst · doi:10.1039/c8an02337a · Cited by 29
Mechanical properties of callus in human tibial fractures: a preliminary investigation
Moorcroft, C. I., Ogrodnik, P. J., Thomas, P. B. M., & Wade, R. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(01)00079-1 · Cited by 26
Fountain, S., Windolf, M., Henkel, J., et al. (2015) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2015.0123 · Cited by 24
Self-citationA Biofeedback System for Continuous Monitoring of Bone Healing
Windolf, M., Ernst, M., Schwyn, R., et al. (2014) · International Conference on Biomedical Electronics and Devices · doi:10.5220/0004913002430248 · Cited by 22
Self-citationA Single-Channel Telemetric Intramedullary Nail for In Vivo Measurement of Fracture Healing
Wilson, D. J., Morgan, R. L., Hesselden, K., et al. (2009) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0b013e3181b01c49 · Cited by 21
The use of strain gauges to measurebone fracture healing—a review
Jenkins, P., & Nokes, L. D. M. (1994) · Current Orthopaedics · doi:10.1016/s0268-0890(05)80065-9 · Cited by 10
Entwicklung eines elektronischen Steifigkeitsmesssystems mit permanenter Datenspeicherung
Schmickal, T., Zwick, A., Schinke, B., et al. (2007) · Trauma und Berufskrankheit · doi:10.1007/s10039-007-1227-2 · Cited by 5
Implantable sensor system for the monitoring of bone healing
Sattler, M., Clauss, J. F., Schmidhuber, M., et al. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-03887-7_81 · Cited by 4
Flagged first, then by citations
Research works printed but not linked: 1
- Sommelet, 1976, Methode objective d'appreciation des deformations du complexe os-implant" in vivo", Par Tele Mesure
Cited by
Sorted by citations
Continuous implant load monitoring to assess bone healing status-evidence from animal testing
Windolf, M., Varjas, V., Gehweiler, D., Schwyn, R., Arens, D., Constant, C., Zeiter, S., Richards, R. G., & Ernst, M. (2022) · Medicina · doi:10.3390/medicina58070858 · Cited by 63
Self-citationConcepts and clinical aspects of active implants for the treatment of bone fractures
Ganse, B., Orth, M., Roland, M., Diebels, S., Motzki, P., Seelecke, S., Kirsch, S.-M., Welsch, F., Andres, A., Wickert, K., et al. (2022) · Acta Biomaterialia · doi:10.1016/j.actbio.2022.05.001 · Cited by 37
Methods to accelerate fracture healing – a narrative review from a clinical perspective
Ganse, B. (2024) · Frontiers in Immunology · doi:10.3389/fimmu.2024.1384783 · Cited by 33
Metadata
- Authors
- Ernst, M., Richards, R. G., & Windolf, M.
- Affiliations
- AO Foundation (CH)
- Corresponding author
- Ernst, Manuela
- Richards, R. Geoff
- Windolf, Markus
- Venue
- Injury
- Publisher
- Elsevier BV
- Published
- 2021-06
- Volume
- 52
- Pages
- S101-S105
- ISSN
- 0020-1383 (ISSN-L)
- OpenAlex
- W3087228553
- Cited by
- 50
- References
- 34
- Citations by year
- 2026: 4 · 2025: 13 · 2024: 12 · 2023: 5 · 2022: 11 · 2021: 3
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Injury (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Surgery › Spinal Fractures and Fixation Techniques
- Health Sciences › Medicine › Surgery › Hip and Femur Fractures
- Keywords
- smart implants, fracture healing, fracture stiffness, nonunion, fracture union, digital health, weight bearing
- MeSH terms
- Humans, Weight-Bearing, Outcome Assessment, Health Care, Fracture Healing, Prostheses and Implants, Fractures, Bone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review