The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Continuous implant load monitoring to assess bone healing status-evidence from animal testing
Open accessAbstract
Background and Objectives: Fracture healing is currently assessed through qualitative evaluation of radiographic images, which is highly subjective in nature. Radiographs can only provide snapshots in time, which are limited due to logistics and radiation exposure. We recently proposed assessing the bone healing status through continuous monitoring of the implant load, utilizing an implanted sensor system, the Fracture Monitor. The device telemetrically transmits statistically derived implant parameters via the patient’s mobile phone to assist physicians in diagnostics and treatment decision-making. This preclinical study aims to systematically investigate the device safety and performance in an animal setting. Materials and Methods: Mid-shaft tibial osteotomies of different sizes (0.6–30 mm) were created in eleven Swiss mountain sheep. The bones were stabilized with either a conventional Titanium or stainless-steel locking plate equipped with a Fracture Monitor. Data were continuously collected over the device’s lifetime. Conventional radiographs and clinical CT scans were taken longitudinally over the study period. The radiographs were systematically scored and CTs were evaluated for normalized bone volume in the defect. The animals were euthanized after 9 months. The sensor output was correlated with the radiologic parameters. Tissue samples from the device location were histologically examined. Results: The sensors functioned autonomously for 6.5–8.4 months until energy depletion. No macroscopic or microscopic adverse effects from device implantation were observed. The relative implant loads at 4 and 8 weeks post-operation correlated significantly with the radiographic scores and with the normalized bone volume metric. Conclusions: Continuous implant load monitoring appears as a relevant approach to support and objectify fracture healing assessments and carries a strong potential to enable patient-tailored rehabilitation in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Epidemiology of Fracture Nonunion in 18 Human Bones
Zura, R., Xiong, Z., Einhorn, T. A., Watson, J. T., Ostrum, R. F., Prayson, M. J., Rocca, G. J. D., Mehta, S. D., McKinley, T. O., Wang, Z., et al. (2016) · JAMA Surgery · doi:10.1001/jamasurg.2016.2775 · Cited by 743
Fracture nonunion in long bones: A literature review of risk factors and surgical management
Nicholson, J. A., Makaram, N. S., Simpson, H., & Keating, J. (2020) · Injury · doi:10.1016/j.injury.2020.11.029 · Cited by 306
Determination of Radiographic Healing
Litrenta, J. M., Tornetta, P., Mehta, S. D., et al. (2015) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0000000000000390 · Cited by 291
The ‘diamond concept’ for long bone non-union management
Andrzejowski, P., & Giannoudis, P. V. (2019) · Journal of Orthopaedics and Traumatology · doi:10.1186/s10195-019-0528-0 · Cited by 279
Outcome Assessment in Clinical Trials of Fracture-Healing
Morshed, S., Corrales, L., Genant, H. K., et al. (2008) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.g.01556 · Cited by 170
Monitoring the Mechanical Properties of Healing Bone
Claes, L., & Cunningham, J. L. (2009) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-009-0752-7 · Cited by 145
Monitoring and healing analysis of 100 tibial shaft fractures
Claes, L., Grass, R., Schmickal, T., Kisse, B., Eggers, C., Gerngro�, H., Mutschler, W., Arand, M., Wintermeyer, T., & Wentzensen, A. (2002) · Langenbeck s Archives of Surgery · doi:10.1007/s00423-002-0306-x · Cited by 137
Loads acting in an intramedullary nail during fracture healing in the human femur
Schneider, E. H., Michel, M. C., Genge, M., Zuber, K., Ganz, R., & Perren, S. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00037-9 · Cited by 127
Concept, design and fabrication of smart orthopedic implants
Burny, F., Donkerwolcke, M., Moulart, F., Bourgois, R., Puers, R., Schuylenbergh, K. V., Barbosa, M. A., Paiva, O. C., Rodes, F., Bégueret, J.-B., et al. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00062-x · Cited by 125
McGilvray, K. C., Unal, E., Troyer, K. L., Santoni, B. G., Palmer, R. H., Easley, J. T., Demir, H. V., & Puttlitz, C. M. (2015) · Journal of Orthopaedic Research® · doi:10.1002/jor.22918 · Cited by 74
Twenty Years Experience in Fracture Healing Measurement with Strain Gauges
Burny, F., Donkerwolcke, M., Bourgois, R., et al. (1984) · Orthopedics · doi:10.3928/0147-7447-19841201-08 · Cited by 67
Design and performance of a fracture monitoring transducer
Evans, M., KENWRIGHT, J., & Cunningham, J. L. (1988) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(88)90028-3 · Cited by 60
Smart bone plates can monitor fracture healing
Lin, M. C., Hu, D. P., Marmor, M. T., Herfat, S. T., Bahney, C. S., & Maharbiz, M. M. (2019) · Scientific Reports · doi:10.1038/s41598-018-37784-0 · Cited by 58
Three-dimensional load measurements in an external fixator
Seide, K., Weinrich, N., Wenzl, M. E., et al. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.025 · Cited by 54
Borchani, W., Aono, K., Lajnef, N., et al. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2496237 · Cited by 51
Telemetric assessment of bone healing with an instrumented internal fixator
Seide, K., Aljudaibi, M., Weinrich, N., Kowald, B., Jürgens, C., Müller, J. W., & Faschingbauer, M. (2012) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.94b3.27550 · Cited by 51
Measurement of the stiffness of fracture callus in vivo. A theoretical study
Bourgois, R., & Burny, F. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90021-8 · Cited by 50
Smart implants in fracture care – Only buzzword or real opportunity
Ernst, M., Richards, R. G., & Windolf, M. (2021) · Injury · doi:10.1016/j.injury.2020.09.026 · Cited by 50
Self-citationKlosterhoff, B. S., Kaiser, J. M., Nelson, B. D., Karipott, S. S., Ruehle, M. A., Hollister, S. J., Weiss, J. A., Ong, K. G., Willett, N. J., & Guldberg, R. E. (2020) · Bone · doi:10.1016/j.bone.2020.115311 · Cited by 41
Telemetering in vivo loads from nail plate implants
Brown, R. H., Burstein, A. H., & Frankel, V. H. (1982) · Journal of Biomechanics · doi:10.1016/0021-9290(82)90046-x · Cited by 40
Clinical feasibility of fracture healing assessment through continuous monitoring of implant load
Ernst, M., Baumgartner, H., Döbele, S., Höntzsch, D., Pohlemann, T., & Windolf, M. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.110188 · Cited by 39
Self-citationJørgensen, T. E. (1972) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677208991258 · Cited by 36
An electronically instrumented internal fixator for the assessment of bone healing
Kienast, B. J., Kowald, B., Seide, K., et al. (2016) · Bone and Joint Research · doi:10.1302/2046-3758.55.2000611 · Cited by 36
Utilizing Multiple BioMEMS Sensors to Monitor Orthopaedic Strain and Predict Bone Fracture Healing
Wolynski, J. G., Sutherland, C. J., Demir, H. V., et al. (2019) · Journal of Orthopaedic Research® · doi:10.1002/jor.24325 · Cited by 36
Implantable strain sensor to monitor fracture healing with standard radiography
Pelham, H., Benza, D., Millhouse, P. W., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-01009-7 · Cited by 30
Windolf, M., Ernst, M., Schwyn, R., Arens, D., & Zeiter, S. (2020) · Injury · doi:10.1016/j.injury.2020.10.050 · Cited by 28
Self-citationThe forgotten phase of fracture healing
Simpson, H. (2017) · Bone and Joint Research · doi:10.1302/2046-3758.610.bjr-2017-0301 · Cited by 27
Fountain, S., Windolf, M., Henkel, J., et al. (2015) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2015.0123 · Cited by 24
Self-citation[Study of consolidation of fractures by deformation gauges in clinical medicine].
Burny, F. (1968) · PubMed · Cited by 22
A Biofeedback System for Continuous Monitoring of Bone Healing
Windolf, M., Ernst, M., Schwyn, R., et al. (2014) · International Conference on Biomedical Electronics and Devices · doi:10.5220/0004913002430248 · Cited by 22
Self-citationA Single-Channel Telemetric Intramedullary Nail for In Vivo Measurement of Fracture Healing
Wilson, D. J., Morgan, R. L., Hesselden, K., et al. (2009) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0b013e3181b01c49 · Cited by 21
[Measuring bone healing in osteosynthesis with external fixator using the Fraktometer FM 100].
Claes, L. (1991) · PubMed · Cited by 21
Labus, K. M., Sutherland, C. J., Notaroš, B. M., et al. (2019) · Journal of Orthopaedic Research® · doi:10.1002/jor.24275 · Cited by 20
Elementary Implantable Force Sensor: For Smart Orthopaedic Implants.
Wachs, R. A., Ellstein, D., Drazan, J. F., et al. (2013) · PubMed · Cited by 19
Simple implantable wireless sensor platform to measure pressure and force
Drazan, J. F., Abdoun, O. T., Wassick, M. T., et al. (2018) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2018.06.006 · Cited by 17
The use of strain gauges to measurebone fracture healing—a review
Jenkins, P., & Nokes, L. D. M. (1994) · Current Orthopaedics · doi:10.1016/s0268-0890(05)80065-9 · Cited by 10
[Clinical use of strain gauges. Current situation and future prospects].
Burny, F., Bourgois, R., Donkerwolcke, M., et al. (1978) · PubMed · Cited by 10
Dunlop, S., Ekegren, C., Edwards, E., et al. (2016) · Value in Health · doi:10.1016/j.jval.2016.08.110 · Cited by 7
Entwicklung eines elektronischen Steifigkeitsmesssystems mit permanenter Datenspeicherung
Schmickal, T., Zwick, A., Schinke, B., et al. (2007) · Trauma und Berufskrankheit · doi:10.1007/s10039-007-1227-2 · Cited by 5
The bottleneck of evidence-based fracture care
Bottlang, M., & Augat, P. (2014) · Injury · doi:10.1016/j.injury.2014.04.001 · Cited by 5
Winkelstabile Osteosyntheseimplantate
Capanni, F., & Jürgens, C. (2007) · Trauma und Berufskrankheit · doi:10.1007/s10039-007-1238-z · Cited by 1
Flagged first, then by citations
Cited by
Sorted by citations
Methods to accelerate fracture healing – a narrative review from a clinical perspective
Ganse, B. (2024) · Frontiers in Immunology · doi:10.3389/fimmu.2024.1384783 · Cited by 33
Metadata
- Authors
- Windolf, M., Varjas, V., Gehweiler, D., Schwyn, R., Arens, D., Constant, C., Zeiter, S., Richards, R. G., & Ernst, M.
- Affiliations
- AO Foundation (CH)
- Corresponding author
- Windolf, Markus
- ORCID
- Venue
- Medicina
- Publisher
- MDPI AG
- Published
- 2022-06-27
- Volume
- 58
- Issue
- 7
- Pages
- 858
- ISSN
- 1010-660X (ISSN-L)
- 1648-9144
- PMC
- PMC9321316
- OpenAlex
- W4283660885
- Cited by
- 63
- References
- 41
- Citations by year
- 2026: 11 · 2025: 23 · 2024: 23 · 2023: 3 · 2022: 3
- FWCI
- 9.39
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Medicina (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- AO Development Incubator
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Surgery › Spinal Fractures and Fixation Techniques
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Keywords
- fracture healing, implantable sensors, tibial osteotomy, bone volume, radiographic scoring, device safety, telemetric data transmission, locking plate, sheep model
- MeSH terms
- Animals, Bone Plates, Fracture Fixation, Internal, Osteotomy, Sheep, Titanium, Fracture Healing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review