A global and updatable ECG beat classification system based on recurrent neural networks and active learning
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The key challenges faced in the automatic diagnosis of arrhythmia by electrocardiogram (ECG) is enormous differences among individual patients and high cost of labeling clinical ECG records. In order to establish a system with an automatic feature learning scheme and an effective optimization mechanism, we propose a global and updatable classification scheme named Global Recurrent Neural Network (GRNN). Recurrent Neural Network (RNN) is adopted to explore the underlying features of ECG beats, based on morphological and temporal information. In order to improve system performance when new samples are obtained, active learning is applied to select the most informative beats and incorporate them into training set. The system is then updated as the training set grows. Our GRNN has three main innovations. Firstly, relying on the large capacity and fitting ability of GRNN, we can classify samples of multiple different patients with a single model. Secondly, the GRNN improves generalization performance when training samples and test samples are from distinct databases. This can be explained that the optimization mechanism finds the most informative samples to improve performance as training data. Finally, RNN automatically learns the underlying differences among the samples from different classes. Experimental results prove that the GRNN system achieves the state-of-the-art performance with a single model. In across-database experiments where the training data and test data are from different databases respectively, the GRNN achieves significant improvement compared with other algorithms. This study illustrates the feasibility of a global and updatable ECG beat classification system in practical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
Supervised Sequence Labelling with Recurrent Neural Networks
Graves, A. (2012) · Studies in Computational Intelligence · doi:10.1007/978-3-642-24797-2 · Cited by 3,120
Adaptive reduction of motion artifact in the electrocardiogram
Tong, D. A., Bartels, K. A., & Honeyager, K. S. (2002) · Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology · doi:10.1109/iembs.2002.1106451 · Cited by 122
Cited by
A review on deep learning methods for ECG arrhythmia classification
Ebrahimi, Z., Loni, M., Daneshtalab, M., & Gharehbaghi, A. (2020) · Expert Systems with Applications: X · doi:10.1016/j.eswax.2020.100033 · Cited by 447
Deep learning in ECG diagnosis: A review
Liu, X., Wang, H., Li, Z., & Qin, L. (2021) · Knowledge-Based Systems · doi:10.1016/j.knosys.2021.107187 · Cited by 436
Self-citationAnsari, Y., Mourad, O., Qaraqe, K., & Serpedin, E. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1246746 · Cited by 291
A Review of Recurrent Neural Network-Based Methods in Computational Physiology
Mao, S., & Sejdić, E. (2023) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2022.3145365 · Cited by 128
Active learning with missing values considering imputation uncertainty
Han, J., & Kang, S. (2021) · Knowledge-Based Systems · doi:10.1016/j.knosys.2021.107079 · Cited by 21
A comprehensive review of AI-Based detection of Arrhythmia using Electrocardiogram (ECG)
Ayyub, A., Politis, C., & Usman, M. A. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110594 · Cited by 18
Metadata
- Authors
- Wang, G., Zhang, C., Liu, Y., Yang, H., Fu, D., Wang, H., & Zhang, P.
- Venue
- Information Sciences
- Publisher
- Elsevier BV
- Published
- 2019-10
- Volume
- 501
- Pages
- 523-542
- ISSN
- 0020-0255 (ISSN-L)
- OpenAlex
- W2810123878
- Cited by
- 124
- References
- 3
- FWCI
- 9.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.