The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Stationary wavelet transform based ECG signal denoising method
Abstract
Electrocardiogram (ECG) signals are used to diagnose cardiovascular diseases. During ECG signal acquisition, various noises like power line interference, baseline wandering, motion artifacts, and electromyogram noise corrupt the ECG signal. As an ECG signal is non-stationary, removing these noises from the recorded ECG signal is quite tricky. In this paper, along with the proposed denoising technique using stationary wavelet transform, various denoising techniques like lowpass filtering, highpass filtering, empirical mode decomposition, Fourier decomposition method, discrete wavelet transform are studied to denoise an ECG signal corrupted with noise. Signal-to-noise ratio, percentage root-mean-square difference, and root mean square error are used to compare the ECG signal denoising performance. The experimental result showed that the proposed stationary wavelet transform based ECG denoising technique outperformed the other ECG denoising techniques as more ECG signal components are preserved than other denoising algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564
Writing Committee Members, Antman, E. M., Anbe, D. T., Armstrong, P. W., Bates, E. R., Green, L. A., Hand, M., Hochman, J. S., Krumholz, H. M., Kushner, F. G., et al. (2004) · Circulation · doi:10.1161/01.cir.0000134791.68010.fa · Cited by 8,356
The impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,812
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939
ACC/AHA Guidelines for the Management of Patients With ST-Elevation Myocardial Infarction
Antman, E. M., Anbe, D. T., Armstrong, P. W., Bates, E. R., Green, L. A., Hand, M., Hochman, J. S., Krumholz, H. M., Kushner, F. G., Lamas, G. A., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.07.014 · Cited by 1,302
Nutzung der EKG-Signaldatenbank CARDIODAT der PTB über das Internet
Bousseljot, R., Kreiseler, D., & Schnabel, A. (2009) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1995.40.s1.317 · Cited by 623
Kaplan Berkaya, S., Uysal, A. K., Sora Gunal, E., Ergin, S., Gunal, S., & Gulmezoglu, M. B. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.03.003 · Cited by 610
Alberdi, A., Aztiria, A., & Basarab, A. (2016) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2015.11.007 · Cited by 473
ECG Signal Denoising By Wavelet Transform Thresholding
Alfaouri, M., & Daqrouq, K. (2008) · American Journal of Applied Sciences · doi:10.3844/ajassp.2008.276.281 · Cited by 398
Van Alste, J. A., & Schilder, T. S. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325514 · Cited by 367
Metadata
- Authors
- Kumar, A., Tomar, H., Mehla, V. K., Komaragiri, R., & Kumar, M.
- Venue
- ISA Transactions
- Publisher
- Elsevier BV
- Published
- 2021-08
- Volume
- 114
- Pages
- 251-262
- ISSN
- 0019-0578 (ISSN-L)
- OpenAlex
- W3110800241
- Cited by
- 264
- References
- 39
- FWCI
- 16.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stationary wavelet transform based ECG signal denoising method. https://app.cochat.ai/papers/10.1016/j.isatra.2020.12.029
- The paper
- Kumar, A., Tomar, H., Mehla, V. K., Komaragiri, R., & Kumar, M. (2021). Stationary wavelet transform based ECG signal denoising method. ISA Transactions. https://doi.org/10.1016/j.isatra.2020.12.029
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.