Skin-like hydrogel devices for wearable sensing, soft robotics and beyond
Open accessThe DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
Skin-like electronics are developing rapidly to realize a variety of applications such as wearable sensing and soft robotics. Hydrogels, as soft biomaterials, have been studied intensively for skin-like electronic utilities due to their unique features such as softness, wetness, biocompatibility and ionic sensing capability. These features could potentially blur the gap between soft biological systems and hard artificial machines. However, the development of skin-like hydrogel devices is still in its infancy and faces challenges including limited functionality, low ambient stability, poor surface adhesion, and relatively high power consumption (as ionic sensors). This review aims to summarize current development of skin-inspired hydrogel devices to address these challenges. We first conduct an overview of hydrogels and existing strategies to increase their toughness and conductivity. Next, we describe current approaches to leverage hydrogel devices with advanced merits including anti-dehydration, anti-freezing, and adhesion. Thereafter, we highlight state-of-the-art skin-like hydrogel devices for applications including wearable electronics, soft robotics, and energy harvesting. Finally, we conclude and outline the future trends.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design, fabrication and control of soft robots
Rus, D., & Tolley, M. T. (2015) · Nature · doi:10.1038/nature14543 · Cited by 5,825
Applications of ionic liquids in the chemical industry
Plechkova, N. V., & Seddon, K. R. (2008) · Chem. Soc. Rev. · doi:10.1039/b006677j · Cited by 5,686 · cited 1×
“ILs have been widely applied in areas such as synthetic chemistry, catalysis, energy storage, and recently sensors and actuators (Buzzeo et al., 2004; Calvert, 2008; Le Bideau et al., 2011; MacFarlane et al., 2014; Plechkova and Seddon, 2008; Watanabe et al., 2017; Zhang et al., 2020c).”
MethodHydrogels for Tissue Engineering
Lee, K. Y., & Mooney, D. J. (2001) · Chemical Reviews · doi:10.1021/cr000108x · Cited by 5,277
Hydrogels for tissue engineering: scaffold design variables and applications
Drury, J. L., & Mooney, D. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00340-5 · Cited by 5,136
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836 · cited 1×
“…stretchable devices have been developed based on our understanding of the human skin’s sensing functions (Benight et al., 2013; Cheng et al., 2019; Kim et al, 2011a, 2011b, 2016a; Lei and Wu, 2018; Liang et al., 2013; Lipomi et al., 2011; Oh et al., 2016; Pelrine et al., 2000; Sekitani et al.,…”
BackgroundHydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109 · cited 2×
“…under different stimuli [e.g., light (Takashima et al., 2012), temperature (Yoshida et al., 1995), pH (Shastri et al., 2015), and ionic strength (He et al., 2012)], which has been utilized for sensing and actuation (Calvert, 2008, 2009; Gong, 2006; Osada and Gong, 1998; Peppas et al., 2006).”
BackgroundWearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373 · cited 3×
“(Wang, 2019).”
BackgroundSkin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes
Lipomi, D. J., Vosgueritchian, M., Tee, B. C.-K., Hellstrom, S. L., Lee, J. A., Fox, C. H., & Bao, Z. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.184 · Cited by 3,188
Sydney Gladman, A., Matsumoto, E. A., Nuzzo, R. G., Mahadevan, L., & Lewis, J. A. (2016) · Nature Materials · doi:10.1038/nmat4544 · Cited by 3,027
Cited by
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Transparent Electronics for Wearable Electronics Application
Won, D., Bang, J., Choi, S. H., Pyun, K. R., Jeong, S., Lee, Y., & Ko, S. H. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00139 · Cited by 339
Self‐Healing Hydrogel Bioelectronics
Li, Z., Lu, J., Ji, T., Xue, Y., Zhao, L., Zhao, K., Jia, B., Wang, B., Wang, J., Zhang, S., et al. (2024) · Advanced Materials · doi:10.1002/adma.202306350 · Cited by 257
Ye, Y., Oguzlu, H., Zhu, J., Zhu, P., Yang, P., Zhu, Y., Wan, Z., Rojas, O. J., & Jiang, F. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202209787 · Cited by 203
Metadata
- Authors
- Ying, B., & Liu, X.
- Venue
- iScience
- Publisher
- Elsevier BV
- Published
- 2021-11
- Volume
- 24
- Issue
- 11
- Pages
- 103174
- ISSN
- 2589-0042 (ISSN-L)
- OpenAlex
- W3203587607
- Cited by
- 230
- References
- 61
- FWCI
- 9.94
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.