Advances in biosensors: Principle, architecture and applications
The DOI matches its Crossref record; 94 of the 94 references it cites were found in a registry or an index.
Abstract
The ability to detect pathogenic and physiologically relevant molecules in the body with high sensitivity and specificity offers a powerful opportunity in the early diagnosis and treatment of diseases. Early detection and diagnosis can be used to greatly reduce the cost of patient care associated with the advanced stages of many diseases. However, despite their widespread clinical use, these techniques have a number of potential limitations. For example, a number of diagnostic devices have slow response times and are burdensome to patients. Furthermore, these assays are expensive and cost the health care industry billions of dollars every year. Therefore, there is a need to develop more efficient and reliable sensing and detection technologies. A biosensor is commonly defined as an analytical device that uses a biological recognition system to target molecules or macromolecules. Biosensors can be coupled to a physiochemical transducer that converts this recognition into a detectable output signal. Typically biosensors are comprised of three components: (1) the detector, which identifies the stimulus; (2) the transducer, which converts this stimulus to a useful output; and (3) the signal processing system, which involves amplification and display of the output in an appropriate format. The goal of this combination is to utilize the high sensitivity and selectivity of biological sensing for analytical purposes in various fields of research and technology. We review here some of the main advances in this field over the past few years, explore the application prospects, and discuss the issues, approaches, and challenges, with the aim of stimulating a broader interest in developing biosensors and improving their applications in medical diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impedance Spectroscopy: Theory, Experiment, and Applications
(2005) · Wiley eBooks · doi:10.1002/0471716243 · Cited by 5,322
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329 · cited 1×
“The 10 measurement of potential response of an potentiometric device is governed by the Nernst 11 equation in which the logarithm of the concentration of the substance being measured is 12 proportional to the potential difference (Grieshaber et al. 2008, Wang Y. et al. 2008).”
Sensitive optical biosensors for unlabeled targets: A review
Fan, X., White, I. M., Shopova, S. I., Zhu, H., Suter, J. D., & Sun, Y. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.05.022 · Cited by 2,187
Electrochemical biosensors: recommended definitions and classification
Thévenot, D. R., Toth, K., Durst, R. A., & Wilson, G. S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00115-4 · Cited by 1,727
Electrochemical biosensors: Towards point-of-care cancer diagnostics
Wang, J. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.10.027 · Cited by 1,454
Electrochemical Biosensors: Recommended Definitions and Classification
Thevenot, D. R., Tóth, K., Durst, R. A., & Wilson, G. S. (1999) · Pure and Applied Chemistry · doi:10.1351/pac199971122333 · Cited by 909
A review of fiber-optic biosensors
Leung, A., Shankar, P. M., & Mutharasan, R. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2007.03.010 · Cited by 693
SHANKARAN, D., GOBI, K., & MIURA, N. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.09.014 · Cited by 607
Enzyme inhibition-based biosensors for food safety and environmental monitoring
Amine, A., Mohammadi, H., Bourais, I., & Palleschi, G. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.07.012 · Cited by 594
McDonnell, J. M. (2001) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(00)00251-9 · Cited by 594
Cited by
A Review on Biosensors and Recent Development of Nanostructured Materials-Enabled Biosensors
Naresh, V., & Lee, N. (2021) · Sensors · doi:10.3390/s21041109 · Cited by 2,066
Biosensors applications in medical field: A brief review
Haleem, A., Javaid, M., Singh, R. P., Suman, R., & Rab, S. (2021) · Sensors International · doi:10.1016/j.sintl.2021.100100 · Cited by 600
Detection principles of biological and chemical FET sensors
Kaisti, M. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.010 · Cited by 577
Recent Developments of Carbon Dots in Biosensing: A Review
Ji, C., Zhou, Y., Leblanc, R. M., & Peng, Z. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01556 · Cited by 461
Nucleic Acid Biosensors: Recent Advances and Perspectives
Du, Y., & Dong, S. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04190 · Cited by 429
Noble metal nanoparticles in biosensors: recent studies and applications
Malekzad, H., Sahandi Zangabad, P., Mirshekari, H., Karimi, M., & Hamblin, M. R. (2017) · Nanotechnology Reviews · doi:10.1515/ntrev-2016-0014 · Cited by 375
Electrochemistry, biosensors and microfluidics: a convergence of fields
Rackus, D. G., Shamsi, M. H., & Wheeler, A. R. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00369a · Cited by 354
Synthesis, Assembly, and Applications of Hybrid Nanostructures for Biosensing
Zhang, S., Geryak, R., Geldmeier, J., Kim, S., & Tsukruk, V. V. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00088 · Cited by 340
Nanomaterials for biocatalyst immobilization – state of the art and future trends
Cipolatti, E. P., Valério, A., Henriques, R. O., Moritz, D. E., Ninow, J. L., Freire, D. M. G., Manoel, E. A., Fernandez-Lafuente, R., & de Oliveira, D. (2016) · RSC Advances · doi:10.1039/c6ra22047a · Cited by 326
Gaudin, V. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.12.005 · Cited by 325
Fundamentals of bio-electrochemical sensing
Shanbhag, M. M., Manasa, G., Mascarenhas, R. J., Mondal, K., & Shetti, N. P. (2023) · Chemical Engineering Journal Advances · doi:10.1016/j.ceja.2023.100516 · Cited by 273
Narita, F., Wang, Z., Kurita, H., Li, Z., Shi, Y., Jia, Y., & Soutis, C. (2021) · Advanced Materials · doi:10.1002/adma.202005448 · Cited by 263
Afreen, S., Muthoosamy, K., Manickam, S., & Hashim, U. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.044 · Cited by 220
“A robust biosensor must be reproducible along with the quality of having a remarkable degree of specificity to an analyte as well as a high sensitivity to detect the target analyte even in a very low concentration (Perez, 2004; Zhang et al., 2000; Perumal and Hashim, 2014).”
BackgroundSelf-citationSkin-Integrated Wearable Systems and Implantable Biosensors: A Comprehensive Review
Rodrigues, D., Barbosa, A. I., Rebelo, R., Kwon, I. K., Reis, R. L., & Correlo, V. M. (2020) · Biosensors · doi:10.3390/bios10070079 · Cited by 220
2D MXene‐Based Biosensing: A Review
Amara, U., Hussain, I., Ahmad, M., Mahmood, K., & Zhang, K. (2023) · Small · doi:10.1002/smll.202205249 · Cited by 216
Advances in Analysis and Detection of Major Mycotoxins in Foods
Agriopoulou, S., Stamatelopoulou, E., & Varzakas, T. (2020) · Foods · doi:10.3390/foods9040518 · Cited by 204
Applications of electrochemical immunosensors for early clinical diagnostics
Burcu Bahadır, E., & Kemal Sezgintürk, M. (2015) · Talanta · doi:10.1016/j.talanta.2014.08.063 · Cited by 202
Methods of detection of food-borne pathogens: a review
Saravanan, A., Kumar, P. S., Hemavathy, R. V., Jeevanantham, S., Kamalesh, R., Sneha, S., & Yaashikaa, P. R. (2021) · Environmental Chemistry Letters · doi:10.1007/s10311-020-01072-z · Cited by 194
“Biosensors mainly contain three elements that are used for the detection of food-borne pathogens: a living capture molecule, a technique for changing capture molecule–target interactions into a sign and an information output system (Perumal and Hashim 2014; Velusamy et al.”
BackgroundProgress in the Applications of Smart Piezoelectric Materials for Medical Devices
Zaszczyńska, A., Gradys, A., & Sajkiewicz, P. (2020) · Polymers · doi:10.3390/polym12112754 · Cited by 192
Dehghani, S., Nosrati, R., Yousefi, M., Nezami, A., Soltani, F., Taghdisi, S. M., Abnous, K., Alibolandi, M., & Ramezani, M. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.03.037 · Cited by 181
Microfluidic devices for sample preparation and rapid detection of foodborne pathogens
Kant, K., Shahbazi, M.-A., Dave, V. P., Ngo, T. A., Chidambara, V. A., Than, L. Q., Bang, D. D., & Wolff, A. (2018) · Biotechnology Advances · doi:10.1016/j.biotechadv.2018.03.002 · Cited by 179
“In general, several different types of bio-recognition molecules, such as antibodies, peptides, aptamers or bacteriophages can be used for efficient pathogen capturing (Perumal and Hashim, 2014; Singh et al., 2014).”
BackgroundElectrochemical-Based Biosensors on Different Zinc Oxide Nanostructures: A Review
Napi, M. L. M., Sultan, S. M., Ismail, R., How, K. W., & Ahmad, M. K. (2019) · Materials · doi:10.3390/ma12182985 · Cited by 174
“The function of the transducer can be clarified as a device that converts the chemical, physical, and biological effects into an electrical signal with high sensitivity and minimum disturbance [44].”
BackgroundAptamer-based biosensor for detecting carcinoembryonic antigen
Xiang, W., Lv, Q., Shi, H., Xie, B., & Gao, L. (2020) · Talanta · doi:10.1016/j.talanta.2020.120716 · Cited by 170
Microbial Fuel Cell-Based Biosensors
Cui, Y., Lai, B., & Tang, X. (2019) · Biosensors · doi:10.3390/bios9030092 · Cited by 167
“Typically, biosensors (Figure 1A) consist of biological recognition elements and physical transducers translating the biologic response into an electrical, thermal, or optical signal correlated to the analyte concentration [4].”
BackgroundBiosensors as a future diagnostic approach for COVID-19
Abid, S. A., Ahmed Muneer, A., Al-Kadmy, I. M. S., Sattar, A. A., Beshbishy, A. M., Batiha, G. E.-S., & Hetta, H. F. (2021) · Life Sciences · doi:10.1016/j.lfs.2021.119117 · Cited by 161
Supraja, P., Sudarshan, V., Tripathy, S., Agrawal, A., & Singh, S. G. (2019) · Analytical Methods · doi:10.1039/c8ay02617c · Cited by 45
Nanomaterial-based electrochemical biosensors for food safety and quality assessment
Dridi, F., Marrakchi, M., Gargouri, M., Saulnier, J., Jaffrezic-Renault, N., & Lagarde, F. (2017) · Nanobiosensors · doi:10.1016/b978-0-12-804301-1.00005-9 · Cited by 40
Metadata
- Authors
- Perumal, V., & Hashim, U.
- Venue
- Journal of Applied Biomedicine
- Published
- 2014-01-01
- Volume
- 12
- Issue
- 1
- Pages
- 1-15
- ISSN
- 1214-021X (ISSN-L)
- 1214-0287
- OpenAlex
- W2062982252
- Cited by
- 606
- References
- 94
- FWCI
- 17.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.