The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
A new approach for catheter ablation of atrial fibrillation: mapping of the electrophysiologic substrate
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Le Mouroux, A., Le Métayer, P., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 7,975
Chen, S.-A., Hsieh, M.-H., Tai, C.-T., Tsai, C.-F., Prakash, V. S., Yu, W.-C., Hsu, T.-L., Ding, Y.-A., & Chang, M.-S. (1999) · Circulation · doi:10.1161/01.cir.100.18.1879 · Cited by 1,446
High-density mapping of electrically induced atrial fibrillation in humans.
Konings, K. T., Kirchhof, C. J., Smeets, J. R., Wellens, H. J., Penn, O. C., & Allessie, M. A. (1994) · Circulation · doi:10.1161/01.cir.89.4.1665 · Cited by 962
Atrial fibrillation as a self-sustaining arrhythmia independent of focal discharge
Moe, G. K., & Abildskov, J. A. (1959) · American Heart Journal · doi:10.1016/0002-8703(59)90274-1 · Cited by 888
High-density mapping of electrically induced atrial fibrillation in humans
Konings, K. T. S., Kirchhof, C. J. H. J., Smeets, J. R. L. M., Wellens, H. J. J., Penn, O. C., & Allessie, M. A. (2000) · Professor Hein J.J. Wellens: 33 Years of Cardiology and Arrhythmology · doi:10.1007/978-94-011-4110-9_54 · Cited by 560
Konings, K. T. S., Smeets, J. L. R. M., Penn, O. C., Wellens, H. J. J., & Allessie, M. A. (1997) · Circulation · doi:10.1161/01.cir.95.5.1231 · Cited by 452
An 8½-Year Clinical Experience with Surgery for Atrial Fibrillation
Cox, J. L., Schuessler, R. B., Lappas, D. G., & Boineau, J. P. (1996) · Annals of Surgery · doi:10.1097/00000658-199609000-00003 · Cited by 428
Catheter Ablation of Paroxysmal Atrial Fibrillation Using a 3D Mapping System
Pappone, C., Oreto, G., Lamberti, F., Vicedomini, G., Loricchio, M. L., Shpun, S., Rillo, M., Calabrò, M. P., Conversano, A., Ben-Haim, S. A., et al. (1999) · Circulation · doi:10.1161/01.cir.100.11.1203 · Cited by 354
Electrophysiologic mechanisms of perpetuation of atrial fibrillation
Allessie, M. A., Konings, K., Kirchhof, C. J. H. J., & Wijffels, M. (1996) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)89114-x · Cited by 203
Regional Disparities of Endocardial Atrial Activation in Paroxysmal Atrial Fibrillation
JAÏS, P., HAÏSSAGUERRE, M., SHAH, D. C., CHOUAIRI, S., & CLÉMENTY, J. (1996) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1996.tb03269.x · Cited by 196
Evidence for transient linking of atrial excitation during atrial fibrillation in humans.
Gerstenfeld, E. P., Sahakian, A. V., & Swiryn, S. (1992) · Circulation · doi:10.1161/01.cir.86.2.375 · Cited by 170
Shpun, S., Gepstein, L., Hayam, G., & Ben-Haim, S. A. (1997) · Circulation · doi:10.1161/01.cir.96.6.2016 · Cited by 159
Identification and Characterization of Atrioventricular Parasympathetic Innervation in Humans
Quan, K. J., Lee, J. H., Hare, G. F. V., Biblo, L. A., Mackall, J. A., & Carlson, M. D. (2002) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2002.00735.x · Cited by 108
Nonfluoroscopic Three‐Dimensional Mapping for Arrhythmia Ablation: Tool or Toy?
Khongphatthanayothin, A., Kosar, E. M., & Nademanee, K. (2000) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2000.tb01792.x · Cited by 60
Self-citationCritical Atrial Site for Ablation of Pacing‐Induced Atrial Fibrillation in the Normal Dog Heart
Tondo, C., Scherlag, B. J., Otomo, K., Antz, M., Patterson, E. S., Arruda, M. S., Jackman, W. M., & Lazzara, R. (1997) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1997.tb01016.x · Cited by 43
LIU, T., TAI, C., & Chen, S. (2002) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2002.01044.x · Cited by 38
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citation
Metadata
- Authors
- Nademanee, K., McKenzie, J., Kosar, E., Schwab, M., Sunsaneewitayakul, B., Vasavakul, T., Khunnawat, C., & Ngarmukos, T.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2004-06
- Volume
- 43
- Issue
- 11
- Pages
- 2044-2053
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2119174768
- Cited by
- 2,002
- References
- 16
- FWCI
- 56.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.