Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 354

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Catheter Ablation of Paroxysmal Atrial Fibrillation Using a 3D Mapping System

Pappone, Carlo, Oreto, Giuseppe, Lamberti, Filippo, Vicedomini, Gabriele, Loricchio, Maria Luisa, Shpun, Shlomo, Rillo, Mariano, Calabrò, Maria Pia, Conversano, Andrea, Ben-Haim, Shlomo A., Cappato, Riccardo, Chierchia, Sergio·1999·Circulation

Abstract

Background —We treated paroxysmal recurrent atrial fibrillation (AF) with radiofrequency (RF) catheter ablation by creating long linear lesions in the atria. To achieve line continuity, a 3D electroanatomic nonfluoroscopic mapping system was used. Methods and Results —In 27 patients with recurrent AF, a catheter incorporating a passive magnetic field sensor was navigated in both atria to construct a 3D activation map. RF energy was delivered to create continuous linear lesions: 3 lines (intercaval, isthmic, and anteroseptal) in the right atrium and a long line encircling the pulmonary veins in the left atrium. After RF application, the atria were remapped to validate completeness of the block lines, demonstrated by late activation of the areas circumscribed by the lines. The mean procedure duration was 312±103 minutes (range, 187 to 495), with mean fluoroscopy time of 107±44 minutes (range, 32 to 185 minutes). No acute complications occurred, but 1 patient experienced early prolonged sinus pauses and received a pacemaker. During the first day, 17 patients (63%) had AF episodes, but at discharge, 25 patients were in sinus rhythm. After a follow-up of 6.0 to 15.3 months (average, 10.5±3.0 months), 16 patients are asymptomatic, 3 have an almost complete disappearance of symptoms, 1 patient is improved, and 7 patients have their AF attacks unchanged. Conclusions —Paroxysmal recurrent drug-refractory AF can be treated by RF catheter ablation. Creation of long continuous linear lesions necessary to compartmentalize the atria is facilitated by a nonfluoroscopic electroanatomic mapping system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.100.11.1203

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 354

Metadata

Authors
Pappone, C., Oreto, G., Lamberti, F., Vicedomini, G., Loricchio, M. L., Shpun, S., Rillo, M., Calabrò, M. P., Conversano, A., Ben-Haim, S. A., Cappato, R., & Chierchia, S.
Venue
Circulation
Published
1999-09-14
Volume
100
Issue
11
Pages
1203-1208
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2108611082
Cited by
354
References
2
FWCI
12.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Catheter Ablation of Paroxysmal Atrial Fibrillation Using a 3D Mapping System. https://app.cochat.ai/papers/10.1161/01.cir.100.11.1203
The paper
Pappone, C., Oreto, G., Lamberti, F., Vicedomini, G., Loricchio, M. L., Shpun, S., Rillo, M., Calabrò, M. P., Conversano, A., Ben-Haim, S. A., Cappato, R., & Chierchia, S. (1999). Catheter Ablation of Paroxysmal Atrial Fibrillation Using a 3D Mapping System. Circulation. https://doi.org/10.1161/01.cir.100.11.1203

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.