The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Multimodal Assessment of the Aortic Annulus Diameter
Open accessAbstract
OBJECTIVES We sought to compare 3 methods of measurements of the aortic annulus, transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), and multislice computed tomography (MSCT), and to evaluate their potential clinical impact on transcatheter aortic valve implantation (TAVI) strategy. BACKGROUND Exact measurement of the aortic annulus is critical for a patient's selection and successful implantation. METHODS Annulus diameter was measured using TTE, TEE, and MSCT in 45 consecutive patients with severe aortic stenosis referred for TAVI. The TAVI strategy (decision to implant and choice of the prosthesis' size) was based on manufacturer's recommendations (Edwards-Sapien prosthesis, Edwards Lifesciences, Inc., Irvine, California). RESULTS Correlations between methods were good but the difference between MSCT and TTE (1.22 +/- 1.3 mm) or TEE (1.52 +/- 1.1 mm) was larger than the difference between TTE and TEE (0.6 +/- 0.8 mm; p = 0.03 and p < 0.0001, respectively). Regarding TAVI strategy, agreement between TTE and TEE overall was good (kappa = 0.68), but TAVI strategy would have been different in 8 patients (17%). Agreement between MSCT and TTE or TEE was only modest (kappa = 0.28 and 0.27), and a decision based on MSCT measurements would have modified the TAVI strategy in a large number of patients (40% to 42%). Implantation, performed in 34 patients (76%) based on TEE measurements, was successful in all but 1 patient with grade 3/4 regurgitation. CONCLUSIONS In patients referred for TAVI, measurements of the aortic annulus using TTE, TEE, and MSCT were close but not identical, and the method used has important potential clinical implications on TAVI strategy. In the absence of a gold standard, a strategy based on TEE measurements provided good clinical results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.176857 · Cited by 8,495
Burden of valvular heart diseases: a population-based study
Nkomo, V. T., Gardin, J. M., Skelton, T. N., Gottdiener, J. S., Scott, C. G., & Enriquez-Sarano, M. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69208-8 · Cited by 4,881
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Zoghbi, W. A., Enriquez-Sarano, M., Foster, E., Grayburn, P. A., Kraft, C. D., Levine, R. A., Nihoyannopoulos, P., Otto, C. M., Quinones, M. A., Rakowski, H., et al. (2003) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(03)00335-3 · Cited by 4,044
Authors/Task Force Members, Vahanian, A., Baumgartner, H., Bax, J., Butchart, E., Dion, R., Filippatos, G., Flachskampf, F., Hall, R., Iung, B., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl428 · Cited by 3,593
Self-citationIung, B. (2003) · European Heart Journal · doi:10.1016/s0195-668x(03)00201-x · Cited by 3,530
Self-citationCribier, A., Eltchaninoff, H., Bash, A., Borenstein, N., Tron, C., Bauer, F., Derumeaux, G., Anselme, F., Laborde, F., & Leon, M. B. (2002) · Circulation · doi:10.1161/01.cir.0000047200.36165.b8 · Cited by 3,172
Echocardiographic Assessment of Valve Stenosis: EAE/ASE Recommendations for Clinical Practice
Baumgartner, H., Hung, J., Bermejo, J., Chambers, J. B., Evangelista, A., Griffin, B. P., Iung, B., Otto, C. M., Pellikka, P. A., & Quiñones, M. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.029 · Cited by 2,126
Self-citationACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.05.021 · Cited by 1,702
Webb, J. G., Pasupati, S., Humphries, K., Thompson, C., Altwegg, L., Moss, R., Sinhal, A., Carere, R. G., Munt, B., Ricci, D., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.698258 · Cited by 1,016
Cited by
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.10.003 · Cited by 12,362
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev014 · Cited by 8,361
Guidelines on the management of valvular heart disease (version 2012)
Authors/Task Force Members, Vahanian, A., Alfieri, O., Andreotti, F., Antunes, M. J., Barón-Esquivias, G., Baumgartner, H., Borger, M. A., Carrel, T. P., De Bonis, M., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs109 · Cited by 3,559
Self-citationGuidelines on the management of valvular heart disease (version 2012)
Authors/Task Force Members, Vahanian, A., Alfieri, O., Andreotti, F., Antunes, M. J., Barón-Esquivias, G., Baumgartner, H., Borger, M. A., Carrel, T. P., De Bonis, M., et al. (2012) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezs455 · Cited by 2,009
Self-citationHahn, R. T., Abraham, T., Adams, M. S., Bruce, C. J., Glas, K. E., Lang, R. M., Reeves, S. T., Shanewise, J. S., Siu, S. C., Stewart, W., et al. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.07.009 · Cited by 1,351
EAE/ASE Recommendations for Image Acquisition and Display Using Three-Dimensional Echocardiography
Lang, R. M., Badano, L. P., Tsang, W., Adams, D. H., Agricola, E., Buck, T., Faletra, F. F., Franke, A., Hung, J., Pérez de Isla, L., et al. (2012) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.11.010 · Cited by 1,129
2012 ACCF/AATS/SCAI/STS Expert Consensus Document on Transcatheter Aortic Valve Replacement
Holmes, D. R., Mack, M. J., Kaul, S., Agnihotri, A., Alexander, K. P., Bailey, S. R., Calhoon, J. H., Carabello, B. A., Desai, M. Y., Edwards, F. H., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.001 · Cited by 749
Ribeiro, H. B., Webb, J. G., Makkar, R. R., Cohen, M. G., Kapadia, S. R., Kodali, S., Tamburino, C., Barbanti, M., Chakravarty, T., Jilaihawi, H., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.07.040 · Cited by 647
EAE/ASE Recommendations for Image Acquisition and Display Using Three-Dimensional Echocardiography
Lang, R. M., Badano, L. P., Tsang, W., Adams, D. H., Agricola, E., Buck, T., Faletra, F. F., Franke, A., Hung, J., de Isla, L. P., et al. (2012) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jer316 · Cited by 600
The Complex Nature of Discordant Severe Calcified Aortic Valve Disease Grading
Clavel, M.-A., Messika-Zeitoun, D., Pibarot, P., Aggarwal, S. R., Malouf, J., Araoz, P. A., Michelena, H. I., Cueff, C., Larose, E., Capoulade, R., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.08.1621 · Cited by 569
Self-citationZamorano, J. L., Badano, L. P., Bruce, C., Chan, K.-L., Gonçalves, A., Hahn, R. T., Keane, M. G., La Canna, G., Monaghan, M. J., Nihoyannopoulos, P., et al. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.07.003 · Cited by 532
Jilaihawi, H., Kashif, M., Fontana, G., Furugen, A., Shiota, T., Friede, G., Makhija, R., Doctor, N., Leon, M. B., & Makkar, R. R. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.11.045 · Cited by 480
Clavel, M.-A., Pibarot, P., Messika-Zeitoun, D., Capoulade, R., Malouf, J., Aggarwal, S. R., Araoz, P. A., Michelena, H. I., Cueff, C., Larose, E., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.05.066 · Cited by 480
Self-citationAbdel-Wahab, M., Zahn, R., Horack, M., Gerckens, U., Schuler, G., Sievert, H., Eggebrecht, H., Senges, J., Richardt, G., & for the German transcatheter aortic valve interventions registry investigators (2011) · Heart · doi:10.1136/hrt.2010.217158 · Cited by 474
Ribeiro, H. B., Rodés-Cabau, J., Blanke, P., Leipsic, J., Kwan Park, J., Bapat, V., Makkar, R., Simonato, M., Barbanti, M., Schofer, J., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx455 · Cited by 430
Willson, A. B., Webb, J. G., LaBounty, T. M., Achenbach, S., Moss, R., Wheeler, M., Thompson, C., Min, J. K., Gurvitch, R., Norgaard, B. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.12.015 · Cited by 407
Recommendations for transoesophageal echocardiography: update 2010
Flachskampf, F. A., Badano, L., Daniel, W. G., Feneck, R. O., Fox, K. F., Fraser, A. G., Pasquet, A., Pepi, M., Perez de Isla, L., Zamorano, J. L., et al. (2010) · European Journal of Echocardiography · doi:10.1093/ejechocard/jeq057 · Cited by 354
Coronary Obstruction Following Transcatheter Aortic Valve Implantation
Ribeiro, H. B., Nombela-Franco, L., Urena, M., Mok, M., Pasian, S., Doyle, D., DeLarochellière, R., Côté, M., Laflamme, L., DeLarochellière, H., et al. (2013) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2012.11.014 · Cited by 337
Zamorano, J. L., Badano, L. P., Bruce, C., Chan, K.-L., Goncalves, A., Hahn, R. T., Keane, M. G., La Canna, G., Monaghan, M. J., Nihoyannopoulos, P., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr259 · Cited by 320
Self-citationTranscatheter aortic valve implantation: current and future approaches
Rodés-Cabau, J. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.164 · Cited by 306
Généreux, P., Stone, G. W., O’Gara, P. T., Marquis-Gravel, G., Redfors, B., Giustino, G., Pibarot, P., Bax, J. J., Bonow, R. O., & Leon, M. B. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.02.057 · Cited by 297
Multidetector Computed Tomography in Transcatheter Aortic Valve Implantation
Leipsic, J., Gurvitch, R., LaBounty, T. M., Min, J. K., Wood, D., Johnson, M., Ajlan, A. M., Wijesinghe, N., & Webb, J. G. (2011) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2011.01.014 · Cited by 287
Van Belle, E., Juthier, F., Susen, S., Vincentelli, A., Iung, B., Dallongeville, J., Eltchaninoff, H., Laskar, M., Leprince, P., Lievre, M., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.002677 · Cited by 241
Self-citationPouch, A. M., Wang, H., Takabe, M., Jackson, B. M., Sehgal, C. M., Gorman, J. H., Gorman, R. C., & Yushkevich, P. A. (2013) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-40811-3_61 · Cited by 25
Metadata
- Authors
- Messika-Zeitoun, D., Serfaty, J.-M., Brochet, E., Ducrocq, G., Lepage, L., Detaint, D., Hyafil, F., Himbert, D., Pasi, N., Laissy, J.-P., Iung, B., & Vahanian, A.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2010-01
- Volume
- 55
- Issue
- 3
- Pages
- 186-194
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W13264575
- Cited by
- 422
- References
- 31
- FWCI
- 48.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.