Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 430

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Incidence, predictors, and clinical outcomes of coronary obstruction following transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: insights from the VIVID registry

Open access
Ribeiro, Henrique B, Rodés-Cabau, Josep, Blanke, Philipp, Leipsic, Jonathon, Kwan Park, Jong, Bapat, Vinayak, Makkar, Raj, Simonato, Matheus, Barbanti, Marco, Schofer, Joachim, Bleiziffer, Sabine, Latib, Azeem, Hildick-Smith, David, Presbitero, Patrizia, Windecker, Stephan, Napodano, Massimo, Cerillo, Alfredo G, Abdel-Wahab, Mohamed, Tchetche, Didier, Fiorina, Claudia, Sinning, Jan-Malte, Cohen, Mauricio G, Guerrero, Mayra E, Whisenant, Brian, Nietlispach, Fabian, Palma, José Honório, Nombela-Franco, Luis, de Weger, Arend, Kass, Malek, Sandoli de Brito, Fabio, Lemos, Pedro A, Kornowski, Ran, Webb, John, Dvir, Danny·2018·European Heart Journal

Abstract

Aims: There are limited data on coronary obstruction following transcatheter valve-in-valve (ViV) implantation inside failed aortic bioprostheses. The objectives of this study were to determine the incidence, predictors, and clinical outcomes of coronary obstruction in transcatheter ViV procedures. Methods and results: A total of 1612 aortic procedures from the Valve-in-Valve International Data (VIVID) Registry were evaluated. Data were subject to centralized blinded corelab computed tomography (CT) analysis in a subset of patients. The virtual transcatheter valve to coronary ostium distance (VTC) was determined. A total of 37 patients (2.3%) had clinically evident coronary obstruction. Baseline clinical characteristics in the coronary obstruction patients were similar to controls. Coronary obstruction was more common in stented bioprostheses with externally mounted leaflets or stentless bioprostheses than in stented with internally mounted leaflets bioprostheses (6.1% vs. 3.7% vs. 0.8%, respectively; P < 0.001). CT measurements were obtained in 20 (54%) and 90 (5.4%) of patients with and without coronary obstruction, respectively. VTC distance was shorter in coronary obstruction patients in relation to controls (3.24 ± 2.22 vs. 6.30 ± 2.34, respectively; P < 0.001). Using multivariable analysis, the use of a stentless or stented bioprosthesis with externally mounted leaflets [odds ratio (OR): 7.67; 95% confidence interval (CI): 3.14-18.7; P < 0.001] associated with coronary obstruction for the global population. In a second model with CT data, a shorter VTC distance predicted this complication (OR: 0.22 per 1 mm increase; 95% CI: 0.09-0.51; P < 0.001), with an optimal cut-off level of 4 mm (area under the curve: 0.943; P < 0.001). Coronary obstruction was associated with a high 30-day mortality (52.9% vs. 3.9% in the controls, respectively; P < 0.001). Conclusion: Coronary obstruction following aortic ViV procedures is a life-threatening complication that occurred more frequently in patients with prior stentless or stented bioprostheses with externally mounted leaflets and in those with a short VTC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehx455

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 430

Metadata

Authors
Ribeiro, H. B., Rodés-Cabau, J., Blanke, P., Leipsic, J., Kwan Park, J., Bapat, V., Makkar, R., Simonato, M., Barbanti, M., Schofer, J., Bleiziffer, S., Latib, A., Hildick-Smith, D., Presbitero, P., Windecker, S., Napodano, M., Cerillo, A. G., Abdel-Wahab, M., Tchetche, D., Fiorina, C., Sinning, J.-M., Cohen, M. G., Guerrero, M. E., Whisenant, B., Nietlispach, F., Palma, J. H., Nombela-Franco, L., de Weger, A., Kass, M., Sandoli de Brito, F., Lemos, P. A., Kornowski, R., Webb, J., & Dvir, D.
Venue
European Heart Journal
Published
2017-08-14
Volume
39
Issue
8
Pages
687-695
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2542845895
Cited by
430
References
16
FWCI
20.66
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Incidence, predictors, and clinical outcomes of coronary obstruction following transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: insights from the VIVID registry. https://app.cochat.ai/papers/10.1093/eurheartj/ehx455
The paper
Ribeiro, H. B., Rodés-Cabau, J., Blanke, P., Leipsic, J., Kwan Park, J., Bapat, V., Makkar, R., Simonato, M., Barbanti, M., Schofer, J., Bleiziffer, S., Latib, A., Hildick-Smith, D., Presbitero, P., Windecker, S., Napodano, M., Cerillo, A. G., Abdel-Wahab, M., Tchetche, D., . . . Dvir, D. (2018). Incidence, predictors, and clinical outcomes of coronary obstruction following transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: insights from the VIVID registry. European Heart Journal. https://doi.org/10.1093/eurheartj/ehx455

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.