Noninvasive Electrocardiographic Mapping to Improve Patient Selection for Cardiac Resynchronization Therapy
Open accessAbstract
OBJECTIVES This study sought to investigate whether noninvasive electrocardiographic activation mapping is a useful method for predicting response to cardiac resynchronization therapy (CRT). BACKGROUND One third of the patients appear not to respond to CRT when they are selected according to QRS duration. METHODS We performed electrocardiographic activation mapping in 33 consecutive CRT candidates (QRS duration ≥120 ms). In 18 patients, the 12-lead electrocardiographic morphology was left bundle branch block (LBBB), and in 15, it was nonspecific intraventricular conduction disturbance (NICD). Three indexes of electrical dyssynchrony were derived from intrinsic maps: right and left ventricular total activation times and ventricular electrical uncoupling (VEU) (difference between the left ventricular [LV] and right ventricular mean activation times). We assessed the ability of these parameters to predict response, measured using a clinical composite score, after 6 months of CRT. RESULTS Electrocardiographic maps revealed homogeneous patterns of activation and consistently greater VEU and LV total activation time (LVTAT) in patients with LBBB compared with heterogeneous activation sequences and shorter VEU and LVTAT in NICD patients (VEU: 75 ± 12 ms vs. 40 ± 22 ms; p < 0.001; LVTAT: 115 ± 21 ms vs. 91 ± 34 ms; p = 0.03). LBBB and NICD patients had similar right ventricular total activation times (62 ± 30 ms vs. 58 ± 26 ms; p = 0.7). The area under the receiver-operating characteristic curve indicated that VEU (area under the curve [AUC]: 0.88) was significantly superior to QRS duration (AUC: 0.73) and LVTAT (AUC: 0.72) for predicting CRT response (p < 0.05). With a 50-ms cutoff value, VEU identified CRT responders with 90% sensitivity and 82% specificity whether LBBB was present or not. CONCLUSIONS Ventricular electrical uncoupling measured by electrocardiographic mapping predicted clinical CRT response better than QRS duration or the presence of LBBB.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cardiac-Resynchronization Therapy for the Prevention of Heart-Failure Events
Moss, A. J., Hall, W. J., Cannom, D. S., Klein, H., Brown, M. W., Daubert, J. P., Estes, N. A. M., Foster, E., Greenberg, H., Higgins, S. L., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0906431 · Cited by 3,157
Cardiac-Resynchronization Therapy for Mild-to-Moderate Heart Failure
Tang, A. S. L., Wells, G. A., Talajic, M., Arnold, M. O., Sheldon, R., Connolly, S., Hohnloser, S. H., Nichol, G., Birnie, D. H., Sapp, J. L., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1009540 · Cited by 1,859 · cited 1×
“Given the high proportion of patients presenting with NICD (approximately one third of the recent RAFT [Resynchronization– Defibrillation for Ambulatory Heart Failure Trial] and REVERSE [Resynchronization Reverses Remodeling in Systolic Left Ventricular Dysfunction] trials) and/or QRS duration <150 ms (40% of the Euro…”
Background
Cited by
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
Self-citation2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Self-citationChung, M. K., Patton, K. K., Lau, C.-P., Dal Forno, A. R. J., Al-Khatib, S. M., Arora, V., Birgersdotter-Green, U. M., Cha, Y.-M., Chung, E. H., Cronin, E. M., et al. (2023) · Heart Rhythm · doi:10.1016/j.hrthm.2023.03.1538 · Cited by 548
Avoiding non-responders to cardiac resynchronization therapy: a practical guide
Daubert, C., Behar, N., Martins, R. P., Mabo, P., & Leclercq, C. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw270 · Cited by 311
Performance and limitations of noninvasive cardiac activation mapping
Duchateau, J., Sacher, F., Pambrun, T., Derval, N., Chamorro-Servent, J., Denis, A., Ploux, S., Hocini, M., Jaïs, P., Bernus, O., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.010 · Cited by 146
Self-citation
Metadata
- Authors
- Ploux, S., Lumens, J., Whinnett, Z., Montaudon, M., Strom, M., Ramanathan, C., Derval, N., Zemmoura, A., Denis, A., De Guillebon, M., Shah, A., Hocini, M., Jaïs, P., Ritter, P., Haïssaguerre, M., Wilkoff, B. L., & Bordachar, P.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2013-06
- Volume
- 61
- Issue
- 24
- Pages
- 2435-2443
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W117247478
- Cited by
- 195
- References
- 2
- FWCI
- 12.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Electrocardiographic Mapping to Improve Patient Selection for Cardiac Resynchronization Therapy. https://app.cochat.ai/papers/10.1016/j.jacc.2013.01.093
- The paper
- Ploux, S., Lumens, J., Whinnett, Z., Montaudon, M., Strom, M., Ramanathan, C., Derval, N., Zemmoura, A., Denis, A., De Guillebon, M., Shah, A., Hocini, M., Jaïs, P., Ritter, P., Haïssaguerre, M., Wilkoff, B. L., & Bordachar, P. (2013). Noninvasive Electrocardiographic Mapping to Improve Patient Selection for Cardiac Resynchronization Therapy. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2013.01.093
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).