CoChat

Rapid-Rate Nonsustained Ventricular Tachycardia Found on Implantable Cardioverter-Defibrillator Interrogation

Open access
Chen, Jay, Johnson, George, Hellkamp, Anne S., Anderson, Jill, Mark, Daniel B., Lee, Kerry L., Bardy, Gust H., Poole, Jeanne E. · 2013 · Journal of the American College of Cardiology
Cited by 67

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Objectives The aim of this study was to examine rapid-rate nonsustained ventricular tachycardia (RR-NSVT) during routine implantable cardioverter-defibrillator (ICD) evaluation in patients with heart failure and its relationship to outcomes. Background The clinical implications of RR-NSVT identified during routine ICD interrogation are unclear. In this study, the occurrence of RR-NSVT and its association with ICD shocks and mortality in SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial) were examined. Methods The 811 patients who received ICDs in SCD-HeFT constituted the study population. The occurrence of RR-NSVT and its association with ICD shocks and mortality in SCD-HeFT were examined. Results RR-NSVT was documented on ICD interrogation in 186 of 811 patients (22.9%). The mean duration of RR-NSVT was 26.4 ± 9.1 beats (7.5 ± 2.6 s), with a mean cycle length of 259 ± 32 ms. Polymorphic RR-NSVT accounted for 56% of episodes. Compared with patients without RR-NSVT, those with RR-NSVT were less likely to be taking beta-blockers, statins, or aspirin at enrollment. After adjusting for other known predictors of mortality in SCD-HeFT, RR-NSVT was independently associated with appropriate ICD shocks (hazard ratio: 4.25; 95% confidence interval: 2.94 to 6.14; p < 0.0001), with all-cause mortality (hazard ratio: 2.40; 95% confidence interval: 1.62 to 3.54; p < 0.0001), and with a composite of all-cause mortality and appropriate ICD shocks (hazard ratio: 3.03; 95% confidence interval: 2.21 to 4.15; p < 0.0001). Conclusions RR-NSVT identified on routine ICD interrogation should be considered an important clinical event. RR-NSVT during ICD interrogation is associated with appropriate ICD shocks and all-cause mortality. The clinical evaluation of patients with RR-NSVT should include intensification of medical therapy, particularly beta-blockers, or other appropriate clinical interventions. (Sudden Cardiac Death in Heart Failure Trial [SCD-HeFT]; NCT00000609)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2013.02.046

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 12

  1. Singh, 1998, Prevalence and significance of nonsustained ventricular tachycardia in patients with premature ventricular contractions and heart failure treated with vasodilator therapy, J Am Coll Cardiol, 32, 942, 10.1016/S0735-1097(98)00338-6 · DOI
  2. Teerlink, 2000, Ambulatory ventricular arrhythmias in patients with heart failure do not specifically predict an increased risk of sudden death, Circulation, 101, 40, 10.1161/01.CIR.101.1.40 · DOI · Paper page
  3. Hlatsky, 1989, A brief self-administered questionnaire to determine functional capacity (the Duke Activity Status Index), Am J Cardiol, 64, 651, 10.1016/0002-9149(89)90496-7 · DOI · Paper page
  4. Poole, 2008, Prognostic importance of defibrillator shocks in patients with heart failure, N Engl J Med, 359, 1009, 10.1056/NEJMoa071098 · DOI · Paper page
  5. Daubert, 2008, Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact, J Am Coll Cardiol, 14, 1357, 10.1016/j.jacc.2007.09.073 · DOI · Paper page
  6. Wathen, 2004, Circulation, 110, 2591, 10.1161/01.CIR.0000145610.64014.E4 · DOI · Paper page
  7. Wilkoff, 2004, Difference in tachyarrhythmia detection and implantable cardioverter defibrillator therapy by primary or secondary prevention indication in cardiac resynchronization therapy patients, J Cardiovasc Electrophysiol, 9, 1002, 10.1046/j.1540-8167.2004.03625.x · DOI · Paper page
  8. Wilkoff, 2008, Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients, J Am Coll Cardiol, 52, 541, 10.1016/j.jacc.2008.05.011 · DOI · Paper page
  9. Gasparini, 2009, Eur Heart J, 22, 2758, 10.1093/eurheartj/ehp247 · DOI · Paper page
  10. Moss, 2012, Reduction in inappropriate therapy and mortality through ICD programming, N Engl J Med, 367, 2275, 10.1056/NEJMoa1211107 · DOI · Paper page
  11. Levantesi, 2007, Meta-analysis of effect of statin treatment on risk of sudden death, Am J Cardiol, 100, 1644, 10.1016/j.amjcard.2007.07.015 · DOI
  12. Vrtovec, 2008, Atorvastatin therapy may reduce the incidence of sudden cardiac death in patients with advanced chronic heart failure, J Cardiovasc Fail, 2, 140, 10.1016/j.cardfail.2007.10.013 · DOI

Cited by

See all 67

Metadata

Authors
Chen, J., Johnson, G., Hellkamp, A. S., Anderson, J., Mark, D. B., Lee, K. L., Bardy, G. H., & Poole, J. E.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2013-05
Volume
61
Issue
21
Pages
2161-2168
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2323903772
Cited by
67
References
4
FWCI
5.72
Type
journal article
Language
en
Open access
bronze
Licence
Funders
  • St. Jude Medical
  • AstraZeneca
  • Medtronic
  • National Heart, Lung, and Blood Institute
  • Eli Lilly and Company
  • Gilead Sciences

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.