The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Differences in Tachyarrhythmia Detection and Implantable Cardioverter Defibrillator Therapy by Primary or Secondary Prevention Indication in Cardiac Resynchronization Therapy Patients
Abstract
Introduction: Although numerous trials have shown benefit of implantable cardioverter defibrillators (ICDs) for either primary or secondary prevention, no trial has prospectively enrolled patients from both indications and analyzed ICD utilization between groups. Methods and Results: We performed a retrospective review of MIRACLE ICD, a randomized, prospective double‐blind trial of cardiac resynchronization therapy (CRT) in the ICD population. Both secondary prevention (N = 563) and primary prevention patients (N = 415) were enrolled. Subgroup analysis for frequency of ventricular tachycardia (VT) and ventricular fibrillation (VF) episodes and detection accuracy revealed that primary prevention patients had a significantly lower frequency of appropriate episodes (0.09 vs 0.43 episodes/month) at significantly faster cycle lengths (303 ± 54 ms vs 366 ± 71 ms, P < 0.0001). These episodes were more likely to be classified as VF by the device and thus receive shock therapy (42% by device classification vs 19% in secondary prevention, P < 0.0001). The absolute rate of inappropriate detections in the primary prevention group per month of follow‐up was lower but constituted a much higher proportion of all episodes (30% vs 14%, P < 0.0001). Most inappropriate detections in the secondary prevention group were due to rapidly conducted atrial fibrillation; most in the primary prevention patients were due to sinus tachycardia. Conclusion: Patients receiving an ICD for CRT therapy with primary prevention indications have a different clinical arrhythmia course than patients with a history of spontaneous VT/VF. This has implications for the optimal programming of ICDs. Longer‐term, prospective evaluation of these differences is warranted and should be investigated in the broader ICD patient population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cardiac Resynchronization in Chronic Heart Failure
Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013168 · Cited by 4,648
Self-citationMoss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912163412503 · Cited by 2,489
Cited by
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Saxon, L. A., Hayes, D. L., Gilliam, F. R., Heidenreich, P. A., Day, J., Seth, M., Meyer, T. E., Jones, P. W., & Boehmer, J. P. (2010) · Circulation · doi:10.1161/circulationaha.110.960633 · Cited by 515
BUNCH, T. J., MUNGER, T. M., FRIEDMAN, P. A., ASIRVATHAM, S. J., BRADY, P. A., CHA, Y., REA, R. F., SHEN, W., POWELL, B. D., OMMEN, S. R., et al. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01192.x · Cited by 109
Impact of hypertension and renin–angiotensin system inhibitors in aortic stenosis
Capoulade, R., Clavel, M., Mathieu, P., Côté, N., Dumesnil, J. G., Arsenault, M., Bédard, É., & Pibarot, P. (2013) · European Journal of Clinical Investigation · doi:10.1111/eci.12169 · Cited by 97
Biering-Sørensen, T., Querejeta Roca, G., Hegde, S. M., Shah, A. M., Claggett, B., Mosley, T. H., Butler, K. R., & Solomon, S. D. (2018) · European Journal of Heart Failure · doi:10.1002/ejhf.928 · Cited by 76
Metadata
- Authors
- WILKOFF, B. L., HESS, M., YOUNG, J., & ABRAHAM, W. T.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2004-08-26
- Volume
- 15
- Issue
- 9
- Pages
- 1002-1009
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2062316006
- Cited by
- 835
- References
- 3
- FWCI
- 7.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Differences in Tachyarrhythmia Detection and Implantable Cardioverter Defibrillator Therapy by Primary or Secondary Prevention Indication in Cardiac Resynchronization Therapy Patients. https://app.cochat.ai/papers/10.1046/j.1540-8167.2004.03625.x
- The paper
- WILKOFF, B. L., HESS, M., YOUNG, J., & ABRAHAM, W. T. (2004). Differences in Tachyarrhythmia Detection and Implantable Cardioverter Defibrillator Therapy by Primary or Secondary Prevention Indication in Cardiac Resynchronization Therapy Patients. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2004.03625.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.