Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 179

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Long-Term Clinical Outcomes of Subcutaneous Versus Transvenous Implantable Defibrillator Therapy

Open access
Brouwer, Tom F., Yilmaz, Dilek, Lindeboom, Robert, Buiten, Maurits S., Olde Nordkamp, Louise R.A., Schalij, Martin J., Wilde, Arthur A., van Erven, Lieselot, Knops, Reinoud E. · 2016 · Journal of the American College of Cardiology

Abstract

BACKGROUND: Transvenous implantable cardioverter-defibrillators (TV-ICDs) improve survival in patients at risk for sudden cardiac death, but complications remain an important drawback. The subcutaneous ICD (S-ICD) was developed to overcome lead-related complications. Comparison of clinical outcomes of both device types in previous studies was hampered by dissimilar patient characteristics. OBJECTIVES: This retrospective study compares long-term clinical outcomes of S-ICD and TV-ICD therapy in a propensity-matched cohort. METHODS: The authors analyzed 1,160 patients who underwent S-ICD or TV-ICD implantation in 2 high-volume hospitals in the Netherlands. Propensity matching for 16 baseline characteristics, including diagnosis, yielded 140 matched pairs. Clinical outcomes were device-related complications requiring surgical intervention, appropriate and inappropriate ICD therapy, and were reported as 5-year Kaplan-Meier rate estimates. RESULTS: All 16 baseline characteristics were balanced in the matched cohort of 140 patients with S-ICDs and 140 patients with TV-ICDs (median age 41 years [interquartile range: 30 to 52 years] and 40% women). The complication rate was 13.7% in the S-ICD group versus 18.0% in the TV-ICD group (p = 0.80). The infection rate was 4.1% versus 3.6% in the TV-ICD groups (p = 0.36). Lead complications were lower in the S-ICD arm compared with the TV-ICD arm, 0.8% versus 11.5%, respectively (p = 0.03). S-ICD patients had more nonlead-related complications than TV-ICD patients, 9.9% versus 2.2%, respectively (p = 0.047). Appropriate ICD intervention (antitachycardia pacing and shocks) occurred more often in the TV-ICD group (hazard ratio [HR]: 2.42; p = 0.01). The incidence of appropriate (TV-ICD HR: 1.46; p = 0.36) and inappropriate shocks (TV-ICD HR: 0.85; p = 0.64) was similar. CONCLUSIONS: The complication rate in patients implanted with an S-ICD or TV-ICD was similar, but their nature differed. The S-ICD reduced lead-related complications significantly, at the cost of nonlead-related complications. Rates of appropriate and inappropriate shocks were similar between the 2 groups.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2016.08.044

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 179

Metadata

Authors
Brouwer, T. F., Yilmaz, D., Lindeboom, R., Buiten, M. S., Olde Nordkamp, L. R. A., Schalij, M. J., Wilde, A. A., van Erven, L., & Knops, R. E.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2016-11
Volume
68
Issue
19
Pages
2047-2055
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2546172332
Cited by
179
References
3
FWCI
18.68
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Long-Term Clinical Outcomes of Subcutaneous Versus Transvenous Implantable Defibrillator Therapy. https://app.cochat.ai/papers/10.1016/j.jacc.2016.08.044
The paper
Brouwer, T. F., Yilmaz, D., Lindeboom, R., Buiten, M. S., Olde Nordkamp, L. R. A., Schalij, M. J., Wilde, A. A., van Erven, L., & Knops, R. E. (2016). Long-Term Clinical Outcomes of Subcutaneous Versus Transvenous Implantable Defibrillator Therapy. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2016.08.044

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.