The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Implant and Midterm Outcomes of the Subcutaneous Implantable Cardioverter-Defibrillator Registry
Open accessAbstract
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to defibrillate ventricular arrhythmias, avoiding drawbacks of transvenous leads. The global EFFORTLESS S-ICD (Evaluation oF FactORs ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD) registry is collecting outcomes in 985 patients during a 5-year follow-up. OBJECTIVES: The primary goal of the EFFORTLESS registry is to determine the safety of the S-ICD by evaluating complications and inappropriate shock rate. METHODS: This is the first report on the full patient cohort and study endpoints with follow-up ≥1 year. The predefined endpoints are 30- and 360-day complications, and shocks for atrial fibrillation or supraventricular tachycardia. RESULTS: Patients were followed for 3.1 ± 1.5 years and 82 completed the study protocol 5-year visit. Average age was 48 years, 28% were women, ejection fraction was 43 ± 18%, and 65% had a primary prevention indication. The S-ICD system and procedure complication rate was 4.1% at 30 days and 8.4% at 360 days. The 1-year complication rate trended toward improvement from the first to last quartile of enrollment (11.3% [quartile 1]) to 7.8% [quartile 2], 6.6% [quartile 3], and 7.4% [quartile 4]; quartile 1 vs. quartiles 2 to 4; p = 0.06). Few device extractions occurred due to need for antitachycardia (n = 5), or biventricular (n = 4) or bradycardia pacing (n = 1). Inappropriate shocks occurred in 8.1% at 1 year and 11.7% after 3.1 years. At implant, 99.5% of patients had a successful conversion of induced ventricular tachycardia or ventricular fibrillation. The 1- and 5-year rates of appropriate shock were 5.8% and 13.5%, respectively. Conversion success for discrete spontaneous episodes was 97.4% overall. CONCLUSIONS: This registry demonstrates that the S-ICD fulfills predefined endpoints for safety and efficacy. Midterm performance rates on complications, inappropriate shocks, and conversion efficacy were comparable to rates observed in transvenous implantable cardioverter-defibrillator studies. (Evaluation oF Factors ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD [The EFFORTLESS S-ICD Registry]; NCT01085435).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moss, A. J., Zareba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,902
Oss, J. M., Areba, W. O. Z., Ackson, W. J., Lein, H. E. K., Ilber, D. A. J. W., Annom, D. A. S. C., Ames, J. M., Aubert, P., Iggins, S. T. L. H., Rown, M. A. W. B., et al. (2002) · Cited by 2,027
Prognostic Importance of Defibrillator Shocks in Patients with Heart Failure
Poole, J. E., Johnson, G. W., Hellkamp, A. S., Anderson, J., Callans, D. J., Raitt, M. H., Reddy, R. K., Marchlinski, F. E., Yee, R., Guarnieri, T., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa071098 · Cited by 1,462
Inappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II
Daubert, J. P., Zareba, W., Cannom, D. S., McNitt, S., Rosero, S. Z., Wang, P., Schuger, C., Steinberg, J. S., Higgins, S. L., Wilber, D. J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.073 · Cited by 813
An Entirely Subcutaneous Implantable Cardioverter–Defibrillator
Bardy, G. H., Smith, W. M., Hood, M. A., Crozier, I. G., Melton, I. C., Jordaens, L., Theuns, D., Park, R. E., Wright, D. J., Connelly, D. T., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0909545 · Cited by 780
Self-citationSafety and Efficacy of a Totally Subcutaneous Implantable-Cardioverter Defibrillator
Weiss, R., Knight, B. P., Gold, M. R., Leon, A. R., Herre, J. M., Hood, M., Rashtian, M., Kremers, M., Crozier, I., Lee, K. L., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.003042 · Cited by 557
Self-citationSaxon, L. A., Hayes, D. L., Gilliam, F. R., Heidenreich, P. A., Day, J., Seth, M., Meyer, T. E., Jones, P. W., & Boehmer, J. P. (2010) · Circulation · doi:10.1161/circulationaha.110.960633 · Cited by 515
Self-citationSafety and Efficacy of the Totally Subcutaneous Implantable Defibrillator
Burke, M. C., Gold, M. R., Knight, B. P., Barr, C. S., Theuns, D. A. M. J., Boersma, L. V. A., Knops, R. E., Weiss, R., Leon, A. R., Herre, J. M., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.02.047 · Cited by 505
Self-citationLambiase, P. D., Barr, C., Theuns, D. A. M. J., Knops, R., Neuzil, P., Johansen, J. B., Hood, M., Pedersen, S., Kääb, S., Murgatroyd, F., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu112 · Cited by 462
Self-citationInappropriate Implantable Cardioverter-Defibrillator Shocks
van Rees, J. B., Borleffs, C. J. W., de Bie, M. K., Stijnen, T., van Erven, L., Bax, J. J., & Schalij, M. J. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.059 · Cited by 451
Cited by
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab670 · Cited by 19,442
2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab368 · Cited by 13,344
Blomström-Lundqvist, C., Traykov, V., Erba, P. A., Burri, H., Nielsen, J. C., Bongiorni, M. G., Poole, J., Boriani, G., Costa, R., Deharo, J.-C., et al. (2020) · EP Europace · doi:10.1093/europace/euz246 · Cited by 423
Metadata
- Authors
- Boersma, L., Barr, C., Knops, R., Theuns, D., Eckardt, L., Neuzil, P., Scholten, M., Hood, M., Kuschyk, J., Jones, P., Duffy, E., Husby, M., Stein, K., & Lambiase, P. D.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2017-08
- Volume
- 70
- Issue
- 7
- Pages
- 830-841
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2745135147
- Cited by
- 331
- References
- 27
- FWCI
- 27.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implant and Midterm Outcomes of the Subcutaneous Implantable Cardioverter-Defibrillator Registry. https://app.cochat.ai/papers/10.1016/j.jacc.2017.06.040
- The paper
- Boersma, L., Barr, C., Knops, R., Theuns, D., Eckardt, L., Neuzil, P., Scholten, M., Hood, M., Kuschyk, J., Jones, P., Duffy, E., Husby, M., Stein, K., & Lambiase, P. D. (2017). Implant and Midterm Outcomes of the Subcutaneous Implantable Cardioverter-Defibrillator Registry. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2017.06.040
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.