Post-Approval U.S. Experience With Left Atrial Appendage Closure for Stroke Prevention in Atrial Fibrillation
Open accessAbstract
BACKGROUND: Left atrial appendage closure (LAAC) was approved by the U.S. Food and Drug Administration (FDA) as a stroke prevention alternative to warfarin for patients with nonvalvular atrial fibrillation. However, clinical decision-making is confounded by the fact that although LAAC attenuates the anticoagulant-related lifetime risk of bleeding, implantation is associated with upfront complications. Thus, enthusiasm for LAAC as a treatment option has been appropriately tempered, particularly as the therapy is introduced beyond the clinical trial sites into general clinical practice. OBJECTIVES: This study evaluated the acute procedural performance and complication rates for all cases performed in the United States since FDA approval. METHODS: In the absence of a formal national clinical registry since regulatory approval in March 2015, we obtained procedural data on implantation procedures. Every LAAC procedure requires the presence of a manufacturer clinical specialist and for procedural parameter and periprocedural complication data to be collected using a standardized process and forms. RESULTS: In 3,822 consecutive cases, implantation was successful in 3,653 (95.6%), with a median procedure time of 50 min (range 10 to 210 min). Implanting physicians performing these procedures (n = 382) included 71% new, nonclinical trial implanters, who performed 50% of the procedures. Procedural complication rates included 39 pericardial tamponades (1.02%) (24 treated percutaneously, 12 surgically, and 3 fatal); 3 procedure-related strokes (0.078%); 9 device embolizations (0.24%) (6 requiring surgical removal); and 3 procedure-related deaths (0.078%). CONCLUSIONS: Despite a large fraction of previously inexperienced operators, in the real-world post-FDA approval experience of LAAC, procedural success was high and complication rates were low.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852 · cited 1×
“31% in a worldwide survey of 20,835 procedures (18) and 1.”
BackgroundHolmes, D. R., Reddy, V. Y., Turi, Z. G., Doshi, S. K., Sievert, H., Buchbinder, M., Mullin, C. M., & Sick, P. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61343-x · Cited by 2,240
Self-citationHolmes, D. R., Kar, S., Price, M. J., Whisenant, B., Sievert, H., Doshi, S. K., Huber, K., & Reddy, V. Y. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.029 · Cited by 1,845
Self-citationReddy, V. Y., Sievert, H., Halperin, J., Doshi, S. K., Buchbinder, M., Neuzil, P., Huber, K., Whisenant, B., Kar, S., Swarup, V., et al. (2014) · JAMA · doi:10.1001/jama.2014.15192 · Cited by 1,018
Self-citationReddy, V. Y., Holmes, D., Doshi, S. K., Neuzil, P., & Kar, S. (2011) · Circulation · doi:10.1161/circulationaha.110.976449 · Cited by 863
Self-citationReddy, V. Y., Doshi, S. K., Sievert, H., Buchbinder, M., Neuzil, P., Huber, K., Halperin, J. L., & Holmes, D. (2013) · Circulation · doi:10.1161/circulationaha.112.114389 · Cited by 677
Self-citationPrevalence and Causes of Fatal Outcome in Catheter Ablation of Atrial Fibrillation
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.02.022 · Cited by 584
Deshmukh, A., Patel, N. J., Pant, S., Shah, N., Chothani, A., Mehta, K., Grover, P., Singh, V., Vallurupalli, S., Savani, G. T., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.003862 · Cited by 581
Tzikas, A., Shakir, S., Gafoor, S., Omran, H., Berti, S., Santoro, G., Kefer, J., Landmesser, U., Nielsen-Kudsk, J. E., Cruz-Gonzalez, I., et al. (2016) · EuroIntervention · doi:10.4244/eijy15m01_06 · Cited by 546
Holmes, D. R., Doshi, S. K., Kar, S., Price, M. J., Sanchez, J. M., Sievert, H., Valderrabano, M., & Reddy, V. Y. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.04.025 · Cited by 543
Self-citationBoersma, L. V. A., Schmidt, B., Betts, T. R., Sievert, H., Tamburino, C., Teiger, E., Pokushalov, E., Kische, S., Schmitz, T., Stein, K. M., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv730 · Cited by 522
Fountain, R. B., Holmes, D. R., Chandrasekaran, K., Packer, D., Asirvatham, S., Van Tassel, R., & Turi, Z. (2006) · American Heart Journal · doi:10.1016/j.ahj.2006.02.005 · Cited by 232
Self-citationBleeding Outcomes After Left Atrial Appendage Closure Compared With Long-Term Warfarin
Price, M. J., Reddy, V. Y., Valderrábano, M., Halperin, J. L., Gibson, D. N., Gordon, N. T., Huber, K. C., & Holmes, D. R. (2015) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2015.08.035 · Cited by 124
Self-citationAlli, O. O., Doshi, S., Kar, S., Reddy, V. Y., Sievert, H., Mullin, C., Swarup, V., Whisenant, B. K., & Holmes, D. R. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.01.061 · Cited by 110
Self-citationAminian, A., Lalmand, J., Tzikas, A., Budts, W., Benit, E., & Kefer, J. (2015) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.25891 · Cited by 101
Time to Cost-Effectiveness Following Stroke Reduction Strategies in AF
Reddy, V. Y., Akehurst, R. L., Armstrong, S. O., Amorosi, S. L., Beard, S. M., & Holmes, D. R. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.09.084 · Cited by 99
Self-citationGangireddy, S. R., Halperin, J. L., Fuster, V., & Reddy, V. Y. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs292 · Cited by 82
Self-citationReddy, V. Y., Akehurst, R. L., Armstrong, S. O., Amorosi, S. L., Brereton, N. J., Hertz, D. S., & Holmes, D. R. (2016) · EP Europace · doi:10.1093/europace/euv412 · Cited by 51
Self-citationLeft atrial appendage closure: First in man with the 4th generation watchman device
Ledwoch, J., Franke, J., Gonzaga, M., Bertog, S. C., Braut, A., Hofmann, I., Vaškelytė, L., Gafoor, S. A., Reddy, V. Y., & Sievert, H. (2015) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.26238 · Cited by 7
Self-citation
Cited by
January, C. T., Wann, L. S., Calkins, H., Chen, L. Y., Cigarroa, J. E., Cleveland, J. C., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., Furie, K. L., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000665 · Cited by 2,744
January, C. T., Wann, L. S., Calkins, H., Chen, L. Y., Cigarroa, J. E., Cleveland, J. C., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., Furie, K. L., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.01.011 · Cited by 2,205
The NCDR Left Atrial Appendage Occlusion Registry
Freeman, J. V., Varosy, P., Price, M. J., Slotwiner, D., Kusumoto, F. M., Rammohan, C., Kavinsky, C. J., Turi, Z. G., Akar, J., Koutras, C., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.12.040 · Cited by 414
Kar, S., Doshi, S. K., Sadhu, A., Horton, R., Osorio, J., Ellis, C., Stone, J., Shah, M., Dukkipati, S. R., Adler, S., et al. (2021) · Circulation · doi:10.1161/circulationaha.120.050117 · Cited by 414
Self-citationJanuary, C. T., Wann, L. S., Calkins, H., Chen, L. Y., Cigarroa, J. E., Cleveland, J. C., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., Furie, K. L., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.01.024 · Cited by 404
Metadata
- Authors
- Reddy, V. Y., Gibson, D. N., Kar, S., O’Neill, W., Doshi, S. K., Horton, R. P., Buchbinder, M., Gordon, N. T., & Holmes, D. R.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2017-01
- Volume
- 69
- Issue
- 3
- Pages
- 253-261
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2546858755
- Cited by
- 257
- References
- 19
- FWCI
- 24.15
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.