Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 254

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

AF Ablation Guided by Spatiotemporal Electrogram Dispersion Without Pulmonary Vein Isolation

Open access
Seitz, Julien, Bars, Clément, Théodore, Guillaume, Beurtheret, Sylvain, Lellouche, Nicolas, Bremondy, Michel, Ferracci, Ange, Faure, Jacques, Penaranda, Guillaume, Yamazaki, Masatoshi, Avula, Uma Mahesh R., Curel, Laurence, Siame, Sabrina, Berenfeld, Omer, Pisapia, André, Kalifa, Jérôme · 2017 · Journal of the American College of Cardiology

Abstract

Background The use of intra-cardiac electrograms to guide atrial fibrillation (AF) ablation has yielded conflicting results. We evaluated an electrogram marker of AF drivers: the clustering of electrograms exhibiting spatio-temporal dispersion — regardless of whether such electrograms were fractionated or not. Objective To evaluate the usefulness of spatio-temporal dispersion, a visually recognizable electric footprint of AF drivers, for the ablation of all forms of AF. Methods We prospectively enrolled 105 patients admitted for AF ablation. AF was sequentially mapped in both atria with a 20-pole PentaRay catheter. We tagged and ablated only regions displaying electrogram dispersion during AF. Results were compared to a validation set in which a conventional ablation approach was used (pulmonary vein isolation/stepwise approach). To establish the mechanism underlying spatio-temporal dispersion of AF electrograms, we conducted realistic numerical simulations of AF drivers in a 2-dimensional model and optical mapping of ovine atrial scar-related AF. Results Ablation at dispersion areas terminated AF in 95%. After ablation of 17±10% of the left atrial surface and 18 months of follow-up, the atrial arrhythmia recurrence rate was 15% after 1.4±0.5 procedure/patient vs 41% in the validation set after 1.5±0.5 procedure/patient (arrhythmia free-survival rates: 85% vs 59%, log rank P<0.001). In comparison with the validation set, radiofrequency times (49 ± 21 minutes vs 85 ± 34.5 minutes, p=0.001) and procedure times (168 ± 42 minutes vs. 230 ± 67 minutes, p<.0001) were shorter. In simulations and optical mapping experiments, virtual PentaRay recordings demonstrated that electrogram dispersion is mostly recorded in the vicinity of a driver. Conclusions The clustering of intra-cardiac electrograms exhibiting spatio-temporal dispersion is indicative of AF drivers. Their ablation allows for a non-extensive and patient-tailored approach to AF ablation. Clinical trial.gov number: NCT02093949

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2016.10.065

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 254

Metadata

Authors
Seitz, J., Bars, C., Théodore, G., Beurtheret, S., Lellouche, N., Bremondy, M., Ferracci, A., Faure, J., Penaranda, G., Yamazaki, M., Avula, U. M. R., Curel, L., Siame, S., Berenfeld, O., Pisapia, A., & Kalifa, J.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2017-01
Volume
69
Issue
3
Pages
303-321
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2578202391
Cited by
254
References
25
FWCI
16.13
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: AF Ablation Guided by Spatiotemporal Electrogram Dispersion Without Pulmonary Vein Isolation. https://app.cochat.ai/papers/10.1016/j.jacc.2016.10.065
The paper
Seitz, J., Bars, C., Théodore, G., Beurtheret, S., Lellouche, N., Bremondy, M., Ferracci, A., Faure, J., Penaranda, G., Yamazaki, M., Avula, U. M. R., Curel, L., Siame, S., Berenfeld, O., Pisapia, A., & Kalifa, J. (2017). AF Ablation Guided by Spatiotemporal Electrogram Dispersion Without Pulmonary Vein Isolation. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2016.10.065

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.