The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Prevention of Arrhythmia Device Infection Trial
Open accessAbstract
BACKGROUND Infection of implanted medical devices has catastrophic consequences. For cardiac rhythm devices, pre-procedural cefazolin is standard prophylaxis but does not protect against methicillin-resistant gram-positive organisms, which are common pathogens in device infections. OBJECTIVE This study tested the clinical effectiveness of incremental perioperative antibiotics to reduce device infection. METHODS The authors performed a cluster randomized crossover trial with 4 randomly assigned 6-month periods, during which centers used either conventional or incremental periprocedural antibiotics for all cardiac implantable electronic device procedures as standard procedure. Conventional treatment was pre-procedural cefazolin infusion. Incremental treatment was pre-procedural cefazolin plus vancomycin, intraprocedural bacitracin pocket wash, and 2-day post-procedural oral cephalexin. The primary outcome was 1-year hospitalization for device infection in the high-risk group, analyzed by hierarchical logistic regression modeling, adjusting for random cluster and cluster-period effects. RESULTS Device procedures were performed in 28 centers in 19,603 patients, of whom 12,842 were high risk. Infection occurred in 99 patients (1.03%) receiving conventional treatment, and in 78 (0.78%) receiving incremental treatment (odds ratio: 0.77; 95% confidence interval: 0.56 to 1.05; p = 0.10). In high-risk patients, hospitalization for infection occurred in 77 patients (1.23%) receiving conventional antibiotics and in 66 (1.01%) receiving incremental antibiotics (odds ratio: 0.82; 95% confidence interval: 0.59 to 1.15; p = 0.26). Subgroup analysis did not identify relevant patient or site characteristics with significant benefit from incremental therapy. CONCLUSIONS The cluster crossover design efficiently tested clinical effectiveness of incremental antibiotics to reduce device infection. Device infection rates were low. The observed difference in infection rates was not statistically significant. (Prevention of Arrhythmia Device Infection Trial [PADIT Pilot] [PADIT]; NCT01002911).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical practice guidelines for antimicrobial prophylaxis in surgery
Bratzler, D. W., Dellinger, E. P., Olsen, K. M., Perl, T. M., Auwaerter, P. G., Bolon, M. K., Fish, D. N., Napolitano, L. M., Sawyer, R. G., Slain, D., et al. (2013) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp120568 · Cited by 2,591
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Dale, W. B., Peter, M. H., & Workgroup, F. T. S. I. P. G. W. (2004) · Clinical Infectious Diseases · doi:10.1086/421095 · Cited by 878
Greenspon, A. J., Patel, J. D., Lau, E., Ochoa, J. A., Frisch, D. R., Ho, R. T., Pavri, B. B., & Kurtz, S. M. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.04.033 · Cited by 780
Management and Outcome of Permanent Pacemaker and Implantable Cardioverter-Defibrillator Infections
Sohail, M. R., Uslan, D. Z., Khan, A. H., Friedman, P. A., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., Stoner, S., & Baddour, L. M. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.072 · Cited by 751
Klug, D., Balde, M., Pavin, D., Hidden-Lucet, F., Clementy, J., Sadoul, N., Rey, J. L., Lande, G., Lazarus, A., Victor, J., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.678664 · Cited by 700
Strategies to Prevent Surgical Site Infections in Acute Care Hospitals
Anderson, D. J., Kaye, K. S., Classen, D., Arias, K. M., Podgorny, K., Burstin, H., Calfee, D. P., Coffin, S. E., Dubberke, E. R., Fraser, V., et al. (2008) · Infection Control & Hospital Epidemiology · doi:10.1086/591064 · Cited by 478
Antimicrobial Prophylaxis in Surgery
(1980) · Postgraduate Medical Journal · doi:10.1136/pgmj.56.653.216 · Cited by 368
Writing Committee Members, Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189741 · Cited by 366
de Oliveira, J. C., Martinelli, M., Nishioka, S. A. D., Varejão, T., Uipe, D., Pedrosa, A. A. A., Costa, R., & Danik, S. B. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.108.795906 · Cited by 349
Edwards, F. H., Engelman, R. M., Houck, P., Shahian, D. M., & Bridges, C. R. (2006) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2005.06.034 · Cited by 333
Pathogenic Mechanisms and Host Interactions in Staphylococcus epidermidis Device-Related Infection
Sabaté Brescó, M., Harris, L. G., Thompson, K., Stanic, B., Morgenstern, M., O'Mahony, L., Richards, R. G., & Moriarty, T. F. (2017) · Frontiers in Microbiology · doi:10.3389/fmicb.2017.01401 · Cited by 239
Clinical Cardiac Pacing, Defibrillation, and Resynchronization Therapy
(2007) · Elsevier eBooks · doi:10.1016/b978-1-4160-2536-8.x5001-8 · Cited by 225
Krahn, A. D., Lee, D. S., Birnie, D., Healey, J. S., Crystal, E., Dorian, P., Simpson, C. S., Khaykin, Y., Cameron, D., Janmohamed, A., et al. (2011) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.110.959791 · Cited by 168
Self-citationParkash, R., Crystal, E., Bashir, J. G., Simpson, C. S., BIRNIE, D. H., Sterns, L. D., Exner, D. V., Thibault, B., Connors, S. P., Healey, J. S., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.924357 · Cited by 91
Self-citationConnolly, S. J., Philippon, F., Longtin, Y., Casanova, A., BIRNIE, D. H., Exner, D. V., Dorian, P., Prakash, R., Alings, M., & Krahn, A. D. (2013) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2013.01.020 · Cited by 61
Self-citationKapa, S., Hyberger, L. K., Rea, R. F., & Hayes, D. L. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00742.x · Cited by 55
Lead‐Associated Endocarditis: The Important Role of Methicillin‐Resistant Staphylococcus aureus
Greenspon, A. J., Rhim, E. S., Mark, G. E., DESIMONE, J., & Ho, R. T. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01039.x · Cited by 50
JAN, E., Camou, F., Texier-Maugein, J., Whinnett, Z. I., Caubet, O., Ploux, S., Pellegrin, J., Ritter, P., Métayer, P. L., Roudaut, R., et al. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02212.x · Cited by 36
Preventing cardiac implantable electronic device infections
Padfield, G. J., Steinberg, C., Bennett, M. T., Chakrabarti, S., Deyell, M. W., Bashir, J. G., & Krahn, A. D. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.06.043 · Cited by 33
Self-citationArrhythmia device lead extraction: Factors that necessitate laser assistance
Gula, L. J., Krahn, A. D., Yee, R. K., et al. (2008) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(08)70681-0 · Cited by 29
Self-citationLopez, W. Y., Rider, S. M., Nwosu, K. C., Kazarian, E. R., Blucher, J. A., Schoenfeld, E. M., Simpson, A. K., Kang, J. D., & Schoenfeld, A. J. (2018) · Spine · doi:10.1097/brs.0000000000002839 · Cited by 28
Cardiovascular implantable electrophysiological device-related infections: a review
Gould, P. A., Gula, L. J., Yee, R. K., Skanes, A. C., Klein, G. J., & Krahn, A. D. (2010) · Current Opinion in Cardiology · doi:10.1097/hco.0b013e328341384e · Cited by 16
Self-citationManagement of infections involving implanted cardiac electrophysiologic devices
Paulin, F. L., Gula, L. J., Yee, R. K., Skanes, A. C., Klein, G. J., & Krahn, A. D. (2008) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-008-0029-6 · Cited by 7
Self-citation
Cited by
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
2023 ESC Guidelines for the management of endocarditis
Delgado, V., Ajmone Marsan, N., de Waha, S., Bonaros, N., Brida, M., Burri, H., Caselli, S., Doenst, T., Ederhy, S., Erba, P. A., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad193 · Cited by 1,754
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Blomström-Lundqvist, C., Traykov, V., Erba, P. A., Burri, H., Nielsen, J. C., Bongiorni, M. G., Poole, J., Boriani, G., Costa, R., Deharo, J.-C., et al. (2020) · EP Europace · doi:10.1093/europace/euz246 · Cited by 423
Antibacterial Envelope to Prevent Cardiac Implantable Device Infection
Tarakji, K. G., Mittal, S., Kennergren, C., Corey, R., Poole, J. E., Schloss, E., Gallastegui, J., Pickett, R. A., Evonich, R., Philippon, F., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1901111 · Cited by 405
Self-citation
Metadata
- Authors
- Krahn, A. D., Longtin, Y., Philippon, F., Birnie, D. H., Manlucu, J., Angaran, P., Rinne, C., Coutu, B., Low, R. A., Essebag, V., Morillo, C., Redfearn, D., Toal, S., Becker, G., Degrâce, M., Thibault, B., Crystal, E., Tung, S., LeMaitre, J., Sultan, O., Bennett, M., Bashir, J., Ayala-Paredes, F., Gervais, P., Rioux, L., Hemels, M. E. W., Bouwels, L. H. R., van Vlies, B., Wang, J., Exner, D. V., Dorian, P., Parkash, R., Alings, M., & Connolly, S. J.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 72
- Issue
- 24
- Pages
- 3098-3109
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2903848086
- Cited by
- 260
- References
- 24
- FWCI
- 15.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.