The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Predictors of Short-Term Complications After Implantable Cardioverter-Defibrillator Replacement: Results From the Ontario ICD Database
Open accessAbstract
Background—: Complications after implantable cardioverter-defibrillator (ICD) replacement are often clinically devastating, particularly when infection or reoperation occurs. Identifying factors contributing to complications may permit identification of high-risk individuals that warrant incremental monitoring and therapy to attenuate risk. In addition, replacement may be a discretionary decision in the context of an advisory or borderline device performance and patient, device, and implanter factors that predict adverse outcome may assist in clinical decision-making. Methods and Results—: In a prospective, multicenter, population-based registry of all ICD patients at 18 centers in Ontario, Canada, we examined 45-day complication and all-cause mortality rates from February 2007 to August 2009 in patients undergoing ICD generator replacement. Complications were determined longitudinally and were categorized as major or minor. ICD replacement was performed in 1081 of 5176 patients (20.8%) undergoing ICD implantation (age, 64.3±12.7 years; 78.5% men). In patients undergoing ICD replacement, 47 patients (4.3%) had a complication within 45 days, with 47 major complications in 28 patients (2.6%), most commonly infection (n=23), lead revision (n=35), electrical storm (n=14), and pulmonary edema (n=13). Minor complications occurred in 2.3% of patients, most commonly incisional infection (n=10) and pocket hematoma (n=10). On multivariable analysis, risk factors associated with major complications were Canadian Cardiovascular Society angina class (adjusted hazard ratio [HR], 3.70 for class 2 to 4 versus 0 to 1; P =0.027) and multiple previous procedures on the pocket (adjusted HR, 3.35 for >1 versus 1; P =0.058). Risk factors associated with any complication were the use of antiarrhythmic therapy (adjusted HR, 6.29; P =0.001), implanter volume (adjusted HR 10.4 for <60/y versus >120/y, P =0.026), and Canadian Cardiovascular Society angina class (adjusted HR, 3.00 for class 2 to 4 versus 0 to 1; P =0.031). In a Cox model with a time-dependent variable of major complication within 45 days after replacement, major complications after ICD replacement were associated with an increased risk of mortality at 45, 90, and 180 days (adjusted HR, 9.61, 12.69, and 6.41, respectively; P =0.002 to 0.039). Conclusions—: Risk factors associated with complications after ICD replacement include the presence of angina, antiarrhythmic therapy, increased number of previous procedures, and low implanter volume. Major complications may be associated with increased risk of subsequent mortality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Wilkoff, B. L., Berul, C. I., Birgersdotter-Green, U. M., Carrillo, R., Cha, Y.-M., Clancy, J., Deharo, J.-C., Ellenbogen, K. A., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.09.001 · Cited by 1,199
Self-citationKirkfeldt, R. E., Johansen, J. B., Nohr, E. A., Jorgensen, O. D., & Nielsen, J. C. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht511 · Cited by 871
Polyzos, K. A., Konstantelias, A. A., & Falagas, M. E. (2015) · EP Europace · doi:10.1093/europace/euv053 · Cited by 493
Lambiase, P. D., Barr, C., Theuns, D. A. M. J., Knops, R., Neuzil, P., Johansen, J. B., Hood, M., Pedersen, S., Kääb, S., Murgatroyd, F., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu112 · Cited by 462
Blomström-Lundqvist, C., Traykov, V., Erba, P. A., Burri, H., Nielsen, J. C., Bongiorni, M. G., Poole, J., Boriani, G., Costa, R., Deharo, J.-C., et al. (2020) · EP Europace · doi:10.1093/europace/euz246 · Cited by 423
Metadata
- Authors
- Krahn, A. D., Lee, D. S., Birnie, D., Healey, J. S., Crystal, E., Dorian, P., Simpson, C. S., Khaykin, Y., Cameron, D., Janmohamed, A., Yee, R., Austin, P. C., Chen, Z., Hardy, J., & Tu, J. V.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2011-04
- Volume
- 4
- Issue
- 2
- Pages
- 136-142
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2547142484
- Cited by
- 168
- References
- 1
- FWCI
- 10.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Predictors of Short-Term Complications After Implantable Cardioverter-Defibrillator Replacement: Results From the Ontario ICD Database. https://app.cochat.ai/papers/10.1161/circep.110.959791
- The paper
- Krahn, A. D., Lee, D. S., Birnie, D., Healey, J. S., Crystal, E., Dorian, P., Simpson, C. S., Khaykin, Y., Cameron, D., Janmohamed, A., Yee, R., Austin, P. C., Chen, Z., Hardy, J., & Tu, J. V. (2011). Predictors of Short-Term Complications After Implantable Cardioverter-Defibrillator Replacement: Results From the Ontario ICD Database. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.110.959791
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.