Predictors of Device-Related Thrombus Following Percutaneous Left Atrial Appendage Occlusion
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
BACKGROUND Device-related thrombus (DRT) has been considered an Achilles' heel of left atrial appendage occlusion (LAAO). However, data on DRT prediction remain limited. OBJECTIVES This study constructed a DRT registry via a multicenter collaboration aimed to assess outcomes and predictors of DRT. METHODS Thirty-seven international centers contributed LAAO cases with and without DRT (device-matched and temporally related to the DRT cases). This study described the management patterns and mid-term outcomes of DRT and assessed patient and procedural predictors of DRT. RESULTS A total of 711 patients (237 with and 474 without DRT) were included. Follow-up duration was similar in the DRT and no-DRT groups, median 1.8 years (interquartile range: 0.9-3.0 years) versus 1.6 years (interquartile range: 1.0-2.9 years), respectively (P = 0.76). DRTs were detected between days 0 to 45, 45 to 180, 180 to 365, and >365 in 24.9%, 38.8%, 16.0%, and 20.3% of patients. DRT presence was associated with a higher risk of the composite endpoint of death, ischemic stroke, or systemic embolization (HR: 2.37; 95% CI, 1.58-3.56; P < 0.001) driven by ischemic stroke (HR: 3.49; 95% CI: 1.35-9.00; P = 0.01). At last known follow-up, 25.3% of patients had DRT. Discharge medications after LAAO did not have an impact on DRT. Multivariable analysis identified 5 DRT risk factors: hypercoagulability disorder (odds ratio [OR]: 17.50; 95% CI: 3.39-90.45), pericardial effusion (OR: 13.45; 95% CI: 1.46-123.52), renal insufficiency (OR: 4.02; 95% CI: 1.22-13.25), implantation depth >10 mm from the pulmonary vein limbus (OR: 2.41; 95% CI: 1.57-3.69), and non-paroxysmal atrial fibrillation (OR: 1.90; 95% CI: 1.22-2.97). Following conversion to risk factor points, patients with ≥2 risk points for DRT had a 2.1-fold increased risk of DRT compared with those without any risk factors. CONCLUSIONS DRT after LAAO is associated with ischemic events. Patient- and procedure-specific factors are associated with the risk of DRT and may aid in risk stratification of patients referred for LAAO.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
5-Year Outcomes After Left Atrial Appendage Closure
Reddy, V. Y., Doshi, S. K., Kar, S., Gibson, D. N., Price, M. J., Huber, K., Horton, R. P., Buchbinder, M., Neuzil, P., Gordon, N. T., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.021 · Cited by 1,032
Self-citationDevice-Related Thrombus After Left Atrial Appendage Closure: Incidence, Predictors, and Outcomes
Dukkipati, S. R., Kar, S., Holmes, D. R., Doshi, S. K., Swarup, V., Gibson, D. N., Maini, B., Gordon, N. T., Main, M. L., & Reddy, V. Y. (2018) · Circulation · doi:10.1161/circulationaha.118.035090 · Cited by 451
Self-citationDevice-Related Thrombosis After Percutaneous Left Atrial Appendage Occlusion for Atrial Fibrillation
Fauchier, L., Cinaud, A., Brigadeau, F., Lepillier, A., Pierre, B., Abbey, S., Fatemi, M., Franceschi, F., Guedeney, P., Jacon, P., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.01.076 · Cited by 352 · cited 5×
“Current published reports suggests that DRT occurs in 3% to 4% of patients post-LAAO, and that DRT is associated with a significantly elevated risk of ischemic events (5,6,9).”
BackgroundInfluentialSelf-citationAtrial Failure as a Clinical Entity
Bisbal, F., Baranchuk, A., Braunwald, E., Bayés de Luna, A., & Bayés-Genís, A. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.11.013 · Cited by 283
Reddy, V. Y., Gibson, D. N., Kar, S., O’Neill, W., Doshi, S. K., Horton, R. P., Buchbinder, M., Gordon, N. T., & Holmes, D. R. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.10.010 · Cited by 257
Self-citationAlkhouli, M., Busu, T., Shah, K., Osman, M., Alqahtani, F., & Raybuck, B. (2018) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2018.09.007 · Cited by 199 · cited 5×
“Among those, device-related thrombus (DRT) is considered an important issue that may affect the success of the LAAO field at large (2,6,8).”
BackgroundResultInfluentialSelf-citationPathophysiology of atrial fibrillation and chronic kidney disease
Ding, W. Y., Gupta, D., Wong, C. F., & Lip, G. Y. H. (2020) · Cardiovascular Research · doi:10.1093/cvr/cvaa258 · Cited by 151 · cited 1×
“The association of renal insufficiency with DRT requires further exploration, with this cohort potentially exhibiting global vascular dysfunction that predispose them to DRT and other thrombotic complications (18).”
BackgroundSelf-citationPracoń, R., Bangalore, S., Dzielińska, Z., Konka, M., Kępka, C., Kruk, M. B. P., Kaczmarska-Dyrda, E., Petryka, J., Bujak, S., Solecki, M., et al. (2018) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.117.005997 · Cited by 122 · cited 6×
“Implantation depth was measured from the pulmonary vein limbus to the atrial aspect of the device to standardize measurement across varying anatomies and device types (10).”
BackgroundMethodInfluentialSelf-citationDetection of Device-Related Thrombosis Following Left Atrial Appendage Occlusion
Korsholm, K., Jensen, J. M., Nørgaard, B. L., & Nielsen‐Kudsk, J. E. (2019) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.119.008112 · Cited by 100 · cited 2×
“Moreover, Korsholm et al (13) (n ¼ 301, of whom 5 had DRT) supported these findings while noting the utility of both TEE and CT for detection.”
ResultSelf-citationHolmes, D. R., Alkhouli, M. A., & Reddy, V. Y. (2019) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2018.09.025 · Cited by 93 · cited 2×
“L eft atrial appendage occlusion (LAAO) offers an alternative to anticoagulation for prevention of stroke in selected patients with atrial fibrillation (AF) (1,2).”
BackgroundSelf-citation
Cited by
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Self-citationJoglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
Metadata
- Authors
- Simard, T., Jung, R. G., Lehenbauer, K., Piayda, K., Pracoń, R., Jackson, G. G., Flores-Umanzor, E., Faroux, L., Korsholm, K., Chun, J. K. R., Chen, S., Maarse, M., Montrella, K., Chaker, Z., Spoon, J. N., Pastormerlo, L. E., Meincke, F., Sawant, A. C., Moldovan, C. M., Qintar, M., Aktas, M. K., Branca, L., Radinovic, A., Ram, P., El-Zein, R. S., Flautt, T., Ding, W. Y., Sayegh, B., Benito-González, T., Lee, O.-H., Badejoko, S. O., Paitazoglou, C., Karim, N., Zaghloul, A. M., Agrawal, H., Kaplan, R. M., Alli, O., Ahmed, A., Suradi, H. S., Knight, B. P., Alla, V. M., Panaich, S. S., Wong, T., Bergmann, M. W., Chothia, R., Kim, J.-S., Pérez de Prado, A., Bazaz, R., Gupta, D., Valderrabano, M., Sanchez, C. E., El Chami, M. F., Mazzone, P., Adamo, M., Ling, F., Wang, D. D., O’Neill, W., Wojakowski, W., Pershad, A., Berti, S., Spoon, D., Kawsara, A., Jabbour, G., Boersma, L. V. A., Schmidt, B., Nielsen-Kudsk, J. E., Rodés-Cabau, J., Freixa, X., Ellis, C. R., Fauchier, L., Demkow, M., Sievert, H., Main, M. L., Hibbert, B., Holmes, D. R., & Alkhouli, M.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2021-07
- Volume
- 78
- Issue
- 4
- Pages
- 297-313
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W3186839920
- Cited by
- 226
- References
- 17
- FWCI
- 25.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Predictors of Device-Related Thrombus Following Percutaneous Left Atrial Appendage Occlusion. https://app.cochat.ai/papers/10.1016/j.jacc.2021.04.098
- The paper
- Simard, T., Jung, R. G., Lehenbauer, K., Piayda, K., Pracoń, R., Jackson, G. G., Flores-Umanzor, E., Faroux, L., Korsholm, K., Chun, J. K. R., Chen, S., Maarse, M., Montrella, K., Chaker, Z., Spoon, J. N., Pastormerlo, L. E., Meincke, F., Sawant, A. C., Moldovan, C. M., . . . Alkhouli, M. (2021). Predictors of Device-Related Thrombus Following Percutaneous Left Atrial Appendage Occlusion. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2021.04.098
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.