Healthy Sleep Patterns and Risk of Incident Arrhythmias
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Background: Emerging evidence has linked sleep behaviors with the risk of cardiac arrhythmias. The various sleep behaviors are typically correlated; however, most of the previous studies only focused on the individual sleep behavior, without considering the overall sleep patterns. Objective: To prospectively investigate the associations between a healthy sleep pattern with the risks of cardiac arrhythmias. Methods: A total of 403,187 participants from UK Biobank were included. A healthy sleep pattern was defined by chronotype, sleep duration, insomnia, snoring, and daytime sleepiness. Weighted genetic risk score (GRS) for atrial fibrillation was calculated. Results: The healthy sleep pattern was significantly associated with lower risks of AF [hazard ratio (HR) comparing extreme categories: 0.71, 95% confidence interval (CI): 0.64–0.80] and bradyarrhythmia (HR: 0.65, 95% CI: 0.54–0.77), but not ventricular arrhythmias, after adjustment for demographic, lifestyle, and genetic risk factors. Compared with individuals with a healthy sleep score of 0–1 (poor sleep group), those with a healthy sleep score of 5 had a 29% and 35% lower risk of developing AF and bradyarrhythmia, respectively. Additionally, the genetic predisposition to AF significantly modified the association of the healthy sleep pattern with the risk of AF (p-interaction=0.017). The inverse association of the healthy sleep pattern with the risk of AF was stronger among those with a lower genetic risk of AF. Conclusions: Our results indicate that a healthy sleep pattern is associated with lower risks of AF and bradyarrhythmia, independent of the traditional risk factors; and the association with AF is modified by genetic susceptibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sudlow, C., Gallacher, J., Allen, N., Beral, V., Burton, P., Danesh, J., Downey, P., Elliott, P., Green, J., Landray, M., et al. (2015) · PLOS Medicine · doi:10.1371/journal.pmed.1001779 · Cited by 12,728
Lloyd-Jones, D. M., Hong, Y., Labarthe, D., Mozaffarian, D., Appel, L. J., Van Horn, L., Greenlund, K., Daniels, S., Nichol, G., Tomaselli, G. F., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.192703 · Cited by 4,750
Worldwide Epidemiology of Atrial Fibrillation: A Global Burden of Disease 2010 Study
Chugh, S. S., Havmoeller, R., Narayanan, K., Singh, D., Rienstra, M., Benjamin, E. J., Gillum, R. F., Kim, Y.-H., McAnulty, J. H., Zheng, Z.-J., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005119 · Cited by 4,506
Obesity and the risk of new-onset atrial fibrillation
Wang, T. J. (2004) · JAMA · doi:10.1001/jama.292.20.2471 · Cited by 1,427
Elevated C-Reactive Protein in Patients With Obstructive Sleep Apnea
Shamsuzzaman, A. S. M., Winnicki, M., Lanfranchi, P., Wolk, R., Kara, T., Accurso, V., & Somers, V. K. (2002) · Circulation · doi:10.1161/01.cir.0000018948.95175.03 · Cited by 974
Yin, J., Jin, X., Shan, Z., Li, S., Huang, H., Li, P., Peng, X., Peng, Z., Yu, K., Bao, W., et al. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.117.005947 · Cited by 721
Page, R. L., Wilkinson, W. E., Clair, W. K., McCarthy, E. A., & Pritchett, E. L. (1994) · Circulation · doi:10.1161/01.cir.89.1.224 · Cited by 627
Zhong, X., Hilton, H. J., Gates, G. J., Jelic, S., Stern, Y., Bartels, M. N., DeMeersman, R. E., & Basner, R. C. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00620.2004 · Cited by 468
Superior Vena Cava Defibrillator Coils Make Transvenous Lead Extraction More Challenging and Riskier
Epstein, L. M., Love, C. J., Wilkoff, B. L., Chung, M. K., Hackler, J. W., Bongiorni, M. G., Segreti, L., Carrillo, R. G., Baltodano, P., Fischer, A., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.12.014 · Cited by 467
Alcohol Consumption and Risk of Atrial Fibrillation
Larsson, S. C., Drca, N., & Wolk, A. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.03.048 · Cited by 436
Cited by
Sleep physiology, pathophysiology, and sleep hygiene
Baranwal, N., Yu, P. K., & Siegel, N. S. (2023) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2023.02.005 · Cited by 540
Epidemiology and modifiable risk factors for atrial fibrillation
Elliott, A. D., Middeldorp, M. E., Van Gelder, I. C., Albert, C. M., & Sanders, P. (2023) · Nature Reviews Cardiology · doi:10.1038/s41569-022-00820-8 · Cited by 368
Atrial Fibrillation and Stress
Segan, L., Prabhu, S., Kalman, J. M., & Kistler, P. M. (2022) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2021.12.008 · Cited by 39
Xue, E., Zhao, J., Ye, J., Wu, J., Chen, D., Shao, J., Li, X., & Ye, Z. (2025) · BMC Medicine · doi:10.1186/s12916-025-03864-y · Cited by 3
Self-citation
Metadata
- Authors
- Li, X., Zhou, T., Ma, H., Huang, T., Gao, X., Manson, J. E., & Qi, L.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2021-09
- Volume
- 78
- Issue
- 12
- Pages
- 1197-1207
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W3200793068
- Cited by
- 153
- References
- 16
- FWCI
- 21.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Healthy Sleep Patterns and Risk of Incident Arrhythmias. https://app.cochat.ai/papers/10.1016/j.jacc.2021.07.023
- The paper
- Li, X., Zhou, T., Ma, H., Huang, T., Gao, X., Manson, J. E., & Qi, L. (2021). Healthy Sleep Patterns and Risk of Incident Arrhythmias. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2021.07.023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.