The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Remote Monitoring for Heart Failure Management at Home
Open accessAbstract
Early telemonitoring of weights and symptoms did not decrease heart failure hospitalizations but helped identify steps toward effective monitoring programs. A signal that is accurate and actionable with response kinetics for early re-assessment is required for the treatment of patients at high risk, while signal specifications differ for surveillance of low-risk patients. Tracking of congestion with cardiac filling pressures or lung water content has shown most impact to decrease hospitalizations, while multiparameter scores from implanted rhythm devices have identified patients at increased risk. Algorithms require better personalization of signal thresholds and interventions. The COVID-19 epidemic accelerated transition to remote care away from clinics, preparing for new digital health care platforms to accommodate multiple technologies and empower patients. Addressing inequities will require bridging the digital divide and the deep gap in access to HF care teams, who will not be replaced by technology but by care teams who can embrace it.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Abraham, W. T., Adamson, P. B., Bourge, R. C., Aaron, M. F., Costanzo, M. R., Stevenson, L. W., Strickland, W., Neelagaru, S., Raval, N., Krueger, S., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60101-3 · Cited by 1,744
Self-citationDo no harm: a roadmap for responsible machine learning for health care
Wiens, J., Saria, S., Sendak, M., Ghassemi, M., Liu, V. X., Doshi-Velez, F., Jung, K., Heller, K., Kale, D., Saeed, M., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0548-6 · Cited by 1,266
Angiotensin-neprilysin inhibition in acute decompensated heart failure
Velazquez, E. J., Morrow, D. A., DeVore, A. D., Duffy, C. I., Ambrosy, A. P., McCague, K., Rocha, R., & Braunwald, E. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1812851 · Cited by 1,260
Telemonitoring in patients with heart failure
Chaudhry, S. I., Mattera, J. A., Curtis, J. P., Spertus, J. A., Herrin, J., Lin, Z., Phillips, C. O., Hodshon, B. V., Cooper, L. S., & Krumholz, H. M. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1010029 · Cited by 1,232
Smart wearable devices in cardiovascular care: Where we are and how to move forward
Bayoumy, K., Gaber, M., Elshafeey, A., Mhaimeed, O., Dineen, E. H., Marvel, F. A., Martin, S. S., Muse, E. D., Turakhia, M. P., Tarakji, K. G., et al. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-021-00522-7 · Cited by 829
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715
Ong, M. K., Romano, P. S., Edgington, S., Aronow, H. U., Auerbach, A. D., Black, J. T., De Marco, T., Escarce, J. J., Evangelista, L. S., Hanna, B., et al. (2016) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.7712 · Cited by 695
Artificial Intelligence in Health Care: A Report From the National Academy of Medicine
Matheny, M. E., Whicher, D., & Thadaney Israni, S. (2020) · JAMA · doi:10.1001/jama.2019.21579 · Cited by 628 · cited 1×
“Principles of responsible AI(70) dictate rigorous evaluation, responsible deployment, and thoughtful reporting within ethical and regulatory standards.(71) We must prioritize inclusive health care AI while addressing biases.”
PEABODY, F. W. (1927) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1927.02680380001001 · Cited by 603
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557
Impact of symptom prevalence and symptom burden on quality of life in patients with heart failure
Zambroski, C. H., Moser, D. K., Bhat, G., & Ziegler, C. (2005) · European Journal of Cardiovascular Nursing · doi:10.1016/j.ejcnurse.2005.03.010 · Cited by 451 · cited 21×
“J Am Coll Cardiol HF. 2020;8(9): 753–755.”
InfluentialBroadband internet access is a social determinant of health!
Benda, N. C., Veinot, T. C., Sieck, C. J., & Ancker, J. S. (2020) · American Journal of Public Health · doi:10.2105/ajph.2020.305784 · Cited by 344 · cited 1×
“The urgent push to virtual care highlighted disparities in access to high-speed reliable internet needed for video visits, recognized as another key social determinant of health.(107) Increasing availability of broadband will increase access to remote management, treating patients where they are with reduced need to t…”
Landolina, M., Perego, G. B., Lunati, M., Curnis, A., Guenzati, G., Vicentini, A., Parati, G., Borghi, G., Zanaboni, P., Valsecchi, S., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.088971 · Cited by 344
Stehlik, J., Schmalfuss, C., Bozkurt, B., Nativi-Nicolau, J., Wohlfahrt, P., Wegerich, S., Rose, K., Ray, R., Schofield, R., Deswal, A., et al. (2020) · Circulation Heart Failure · doi:10.1161/circheartfailure.119.006513 · Cited by 333
Eberly, L. A., Richterman, A., Beckett, A. G., Wispelwey, B., Marsh, R. H., Cleveland Manchanda, E. C., Chang, C. Y., Glynn, R. J., Brooks, K. C., Boxer, R., et al. (2019) · Circulation: Heart Failure · doi:10.1161/circheartfailure.119.006214 · Cited by 189
Wearable devices—addressing bias and inequity
Zinzuwadia, A., & Singh, J. P. (2022) · The Lancet Digital Health · doi:10.1016/s2589-7500(22)00194-7 · Cited by 58 · cited 1×
“We must prioritize inclusive health care AI while addressing biases.(72) There is little doubt that multiple levels of AI will be incorporated into the discovery and processing of remote monitoring signals for both automatic and clinician-facilitated HFM (Figure 4).”
The implementation cost of a safety‐net hospital program addressing social needs in Atlanta
MacLeod, K. E., Chapel, J. M., McCurdy, M., Minaya‐Junca, J., Wirth, D., Onwuanyi, A., & Lane, R. I. (2021) · Health Services Research · doi:10.1111/1475-6773.13629 · Cited by 12
Cited by
Transforming Cardiovascular Care With Artificial Intelligence: From Discovery to Practice
Khera, R., Oikonomou, E. K., Nadkarni, G. N., Morley, J. R., Wiens, J., Butte, A. J., & Topol, E. J. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2024.05.003 · Cited by 264
Marvasti, T. B., Gao, Y., Murray, K. R., Hershman, S., McIntosh, C., & Moayedi, Y. (2024) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2024.07.009 · Cited by 35
Metadata
- Authors
- Stevenson, L. W., Ross, H. J., Rathman, L. D., & Boehmer, J. P.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2023-06
- Volume
- 81
- Issue
- 23
- Pages
- 2272-2291
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W4379472401
- Cited by
- 175
- References
- 17
- FWCI
- 30.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.