Background The assumption that the assessment of FEF25-75 does not provide additional information in asthmatic children with normal FEV1 % predicted has not been adequately tested. Objective To determine whether the measurement of the FEF25-75 % predicted offers advantages over the FEV1 % predicted and the FEV1/FVC % predicted for the evaluation of childhood asthma. Methods and Measurements This is a secondary analysis of data from the “Pediatric Asthma Controller Trial” and the “Characterizing the Response to a Leukotriene Receptor Antagonist and Inhaled Corticosteroid” trials. Pearson correlation coefficients, Pearson partial correlation coefficients, canonical correlations, and receiver operator characteristic (ROC) curves were constructed. Results Among 437 children with normal FEV1 % predicted, FEF25-75 % predicted and FEV1/FVC % predicted were (1) positively correlated with log2 methacholine PC20, (2) positively correlated with morning and evening peak expiratory flow % predicted, and (3) negatively correlated with log10 FeNO and bronchodilator responsiveness. Pearson partial correlations and canonical correlations indicated that FEF25-75 % predicted was better correlated with bronchodilator responsiveness and log2 methacholine PC20 than were the FEV1 % predicted or FEV1/FVC % predicted. In the ROC curve analysis, FEF25-75 at 65% predicted had a 90% sensitivity and a 67% specificity for detecting a 20% increase in FEV1 following albuterol inhalation. Conclusion FEF25-75 % predicted was well correlated with bronchodilator responsiveness in asthmatic children with normal FEV1. FEF25-75 % predicted should be evaluated in clinical studies of asthma in children, and may be of use in predicting the presence of clinically relevant reversible airflow obstruction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miller, M. R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Crapo, R., Enright, P., van der Grinten, C. P. M., Gustafsson, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034805 · Cited by 15,627
Interpretative strategies for lung function tests
Pellegrino, R., Viegi, G., Brusasco, V., Crapo, R. O., Burgos, F., Casaburi, R., Coates, A., van der Grinten, C. P. M., Gustafsson, P., Hankinson, J., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00035205 · Cited by 5,945
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-710st · Cited by 3,203
Outcome of Asthma and Wheezing in the First 6 Years of Life
Morgan, W. J., Stern, D. A., Sherrill, D. L., Guerra, S., Holberg, C. J., Guilbert, T. W., Taussig, L. M., Wright, A. L., & Martinez, F. D. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200504-525oc · Cited by 650
Self-citation
Cited by
International ERS/ATS guidelines on definition, evaluation and treatment of severe asthma
Chung, K. F., Wenzel, S. E., Brozek, J. L., Bush, A., Castro, M., Sterk, P. J., Adcock, I. M., Bateman, E. D., Bel, E. H., Bleecker, E. R., et al. (2014) · European Respiratory Journal · doi:10.1183/09031936.00202013 · Cited by 3,926
Overweight, Obesity, and Lung Function in Children and Adults—A Meta-analysis
Forno, E., Han, Y.-Y., Mullen, J., & Celedón, J. C. (2018) · The Journal of Allergy and Clinical Immunology: In Practice · doi:10.1016/j.jaip.2017.07.010 · Cited by 286
Metadata
- Authors
- Simon, M. R., Chinchilli, V. M., Phillips, B. R., Sorkness, C. A., Lemanske, R. F., Szefler, S. J., Taussig, L., Bacharier, L. B., & Morgan, W.
- Venue
- Journal of Allergy and Clinical Immunology
- Publisher
- Elsevier BV
- Published
- 2010-09
- Volume
- 126
- Issue
- 3
- Pages
- 527-534.e8
- ISSN
- 0091-6749 (ISSN-L)
- OpenAlex
- W2065212355
- Cited by
- 175
- References
- 4
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Forced expiratory flow between 25% and 75% of vital capacity and FEV1/forced vital capacity ratio in relation to clinical and physiological parameters in asthmatic children with normal FEV1 values. https://app.cochat.ai/papers/10.1016/j.jaci.2010.05.016
- The paper
- Simon, M. R., Chinchilli, V. M., Phillips, B. R., Sorkness, C. A., Lemanske, R. F., Szefler, S. J., Taussig, L., Bacharier, L. B., & Morgan, W. (2010). Forced expiratory flow between 25% and 75% of vital capacity and FEV1/forced vital capacity ratio in relation to clinical and physiological parameters in asthmatic children with normal FEV1 values. Journal of Allergy and Clinical Immunology. https://doi.org/10.1016/j.jaci.2010.05.016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.