Cited by 64Infection Control and VentilationAerosol Filtration and Electrostatic PrecipitationInhalation and Respiratory Drug Delivery

Effect of Particle Size on the Performance of an N95 Filtering Facepiece Respirator and a Surgical Mask at Various Breathing Conditions

Open access
He, Xinjian, Reponen, Tiina, McKay, Roy T., Grinshpun, Sergey A.·2013·Aerosol Science and Technology

Abstract

The effect of aerosol particle size on the performance of an N95 filtering facepiece respirator (FFR) and a surgical mask (SM) was evaluated under different breathing conditions, including breathing frequency and mean inspiratory flow (MIF) rate. The FFR and SM were sealed on a manikin headform and challenged with charge-equilibrated NaCl aerosol. Filter penetration (P filter) was determined as the ratio of aerosol concentrations inside and outside the FFR/SM size-selectively (28 channels) within a range of 20 to 500 nm. In addition, the same models of the FFR and SM were donned, but not sealed, on an advanced manikin headform covered with skin-like material. Total inward leakage (TIL), which represents the total particle penetration, was measured under conditions identical to the filter penetration experiment. Testing was conducted at four mean MIFs (15, 30, 55, and 85 L/min) combined with five breathing frequencies (10, 15, 20, 25, and 30 breaths/min). The results show that SM produced much higher P filter and TIL values, and thus provide little protection against aerosols in the size range tested. P filter was significantly affected by particle size and breathing flow rate (p < 0.05) for the tested FFR and SM. Surprisingly, for both devices, P filter as a function of the particle size exhibited more than one peak under all tested breathing conditions. The effect of breathing frequency on P filter was generally less pronounced, especially for lower MIFs. For the FFR and SM, TIL increased with increasing particle size up to about 50 nm; for particles above 50 nm, the total penetration was not significantly affected by particle size and breathing frequency; however, the effect of MIF remained significant. Copyright 2013 American Association for Aerosol Research

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/02786826.2013.829209

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 3

  1. Grafe T, Gogins M, Barris M, Schaefer J and Canepa R (2001). “ Nanofibers in Filtration Applications in Transportation”. Filtration 2001 Conference Proceedings, Chicago, IL; 1– 15.
  2. Grinshpun SA, Haruta H, Eninger RM, Reponen T, McKay RT and Lee SA (2009b). Performance of an N95 Filtering Facepiece Particulate Respirator and a Surgical Mask During Human Breathing: Two Pathways for Particle Penetration. J. Occup. Environ. Hyg 6: 593– 603. 19598054 PMC7196699
  3. NIOSH (1995). National Institute for Occupational Safety and Health. Us Dhhs, Public Health Service. “ Respiratory Protective Devices; Final Rules and Notices” Federal Register 60: 110, pp. 30335– 30393.

Cited by

Sorted by citations

Authors
He, X., Reponen, T., McKay, R. T., & Grinshpun, S. A.
Affiliations
University of Cincinnati (US)
Venue
Aerosol Science and Technology
Published
2013-11
Volume
47
Issue
11
Pages
1180-1187
ISSN
  • 0278-6826 (ISSN-L)
  • 1521-7388
OpenAlex
W2073215115
Cited by
64
References
29
Citations by year
2025: 1 · 2024: 1 · 2023: 5 · 2022: 9 · 2021: 18 · 2020: 19 · 2019: 2 · 2018: 4 · 2016: 3 · 2015: 2
FWCI
1.36
Type
journal article
Language
en
Open access
Locations
  • Aerosol Science and Technology (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • University of Cincinnati
  • National Institute for Occupational Safety and Health (T42-OH008432, OH008432)
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Inhalation and Respiratory Drug Delivery
Keywords
N95 respirators, surgical masks, particle size, filter penetration, breathing conditions, respiratory rate, NaCl aerosol, respiratory protection, aerosol filtration

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review