Characterizing the performance of two optical particle counters (Grimm OPC1.108 and OPC1.109) under urban aerosol conditions
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
The performance of Grimm optical particle counters (OPC, models 1.108 and 1.109) was characterized under urban aerosol conditions. Number concentrations were well correlated. The different lower cut-off diameters (0.25 and 0.3 μm) give an average difference of 23.5%. Both detect less than 10% of the total particle concentration (0.01-1 μm; Differential Mobility Analyzer), but in the respective size ranges, differences are <10%. OPC number size distributions were converted to mass concentrations using instrument-specific factors given by the manufacturer. Mass concentrations for OPC1.108 were 60% higher than for OPC1.109 and (in case of OPC1.109) much lower than those measured with an impactor in the relevant size range or a TSP filter. Using the C-factor correction suggested by the manufacturer, OPC1.109 underestimated mass concentrations by 21% (impactor) and by about 36% (TSP filter), which is in the range of comparability of co-located different mass concentration methods (Hitzenberger, Berner, Maenhaut, Cafmeyer, Schwarz, & Mueller et al., 2004).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An association between air pollution and mortality in six U.S. cities
Dockery, D. W., Pope, C. A., Xu, X., Spengler, J. D., Ware, J. H., Fay, M. E., Ferris, B. G., & Speizer, F. E. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312093292401 · Cited by 8,018
Health Effects of Fine Particulate Air Pollution: Lines that Connect
Pope, C. A., & Dockery, D. W. (2006) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2006.10464485 · Cited by 6,583
Acute Respiratory Effects of Particulate Air Pollution
Dockery, D. W., & Pope, C. A. (1994) · Annual Review of Public Health · doi:10.1146/annurev.pu.15.050194.000543 · Cited by 2,177
Aerosol Measurement: Principles, Techniques, and Applications
(2011) · Wiley eBooks · doi:10.1002/9781118001684 · Cited by 1,352
Airborne Particulate Matter and Human Health: A Review
Davidson, C. I., Phalen, R. F., & Solomon, P. A. (2005) · Aerosol Science and Technology · doi:10.1080/02786820500191348 · Cited by 803
Brugge, D., Durant, J. L., & Rioux, C. (2007) · Environmental Health · doi:10.1186/1476-069x-6-23 · Cited by 512
MORTALITY AND AIR POLLUTION J LONDON: A TIME SERIES ANALYSIS
SCHWARTZ, J., & MARCUS, A. (1990) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a115473 · Cited by 439
Samoli, E., Analitis, A., Touloumi, G., Schwartz, J., Anderson, H. R., Sunyer, J., Bisanti, L., Zmirou, D., Vonk, J. M., Pekkanen, J., et al. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7387 · Cited by 335
Evaluation of the TEOM® Method for Measurement of Ambient Particulate Mass in Urban Areas
Allen, G., Sioutas, C., Koutrakis, P., Reiss, R., Lurmann, F. W., & Roberts, P. T. (1997) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1997.10463923 · Cited by 273
Air pollution and mortality: A history
Anderson, H. R. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.09.026 · Cited by 180
Cited by
Malings, C., Tanzer, R., Hauryliuk, A., Saha, P. K., Robinson, A. L., Presto, A. A., & Subramanian, R. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1623863 · Cited by 343
Field calibrations of a low-cost aerosol sensor at a regulatory monitoring site in California
Holstius, D. M., Pillarisetti, A., Smith, K. R., & Seto, E. (2014) · Atmospheric Measurement Techniques · doi:10.5194/amt-7-1121-2014 · Cited by 312
Sousan, S., Koehler, K., Hallett, L., & Peters, T. M. (2016) · Aerosol Science and Technology · doi:10.1080/02786826.2016.1232859 · Cited by 210
“For environmental urban settings, Burkart et al. (2010) found the PAS-1.”
Kumar, P., Skouloudis, A. N., Bell, M., Viana, M., Carotta, M. C., Biskos, G., & Morawska, L. (2016) · Science of The Total Environment · doi:10.1016/j.scitotenv.2016.04.032 · Cited by 201
Metadata
- Authors
- Burkart, J., Steiner, G., Reischl, G., Moshammer, H., Neuberger, M., & Hitzenberger, R.
- Venue
- Journal of Aerosol Science
- Publisher
- Elsevier BV
- Published
- 2010-10
- Volume
- 41
- Issue
- 10
- Pages
- 953-962
- ISSN
- 0021-8502 (ISSN-L)
- OpenAlex
- W1989258851
- Cited by
- 160
- References
- 15
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterizing the performance of two optical particle counters (Grimm OPC1.108 and OPC1.109) under urban aerosol conditions. https://app.cochat.ai/papers/10.1016/j.jaerosci.2010.07.007
- The paper
- Burkart, J., Steiner, G., Reischl, G., Moshammer, H., Neuberger, M., & Hitzenberger, R. (2010). Characterizing the performance of two optical particle counters (Grimm OPC1.108 and OPC1.109) under urban aerosol conditions. Journal of Aerosol Science. https://doi.org/10.1016/j.jaerosci.2010.07.007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.