Effects of surface smoothness on inertial particle deposition in human nasal models
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Computational fluid dynamics (CFD) predictions of inertial particle deposition have not compared well with data from nasal replicas due to effects of surface texture and the resolution of tomographic images. To study effects of geometric differences between CFD models and nasal replicas, nasal CFD models with different levels of surface smoothness were reconstructed from the same MRI data used to construct the nasal replica used by Kelly et al. (2004) [Aerosol Sci. Technol. 38:1063–1071]. One CFD model in particular was reconstructed without any surface smoothing to preserve the detailed topology present in the nasal replica. Steady-state inspiratory airflow and Lagrangian particle tracking were simulated using Fluent software. Particle deposition estimates from the smoother models under-predicted nasal deposition from replica casts, which was consistent with previous findings. These discrepancies were overcome by including surface artifacts that were not present in the reduced models and by plotting deposition efficiency versus the Stokes number, where the characteristic diameter was defined in terms of the pressure-flow relationship to account for changes in airflow resistance due to wall roughness. These results indicate that even slight geometric differences have significant effects on nasal deposition and that this information should be taken into account when comparing particle deposition data from CFD models with experimental data from nasal replica casts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles
LAUCKS, M. L. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00571-6 · Cited by 3,367
(1998) · Spoken Language System and Corpus Design · doi:10.1515/9783110809817.1 · Cited by 1,488
Dispersion and Deposition of Spherical Particles from Point Sources in a Turbulent Channel Flow
Li, A., & Ahmadi, G. (1992) · Aerosol Science and Technology · doi:10.1080/02786829208959550 · Cited by 1,002 · cited 2×
“(Li and Ahmadi, 1992), and Rep is the particle Reynolds number, given by .”
BackgroundEffect of Anatomy on Human Nasal Air Flow and Odorant Transport Patterns: Implications for Olfaction
Zhao, K. (2004) · Chemical Senses · doi:10.1093/chemse/bjh033 · Cited by 361 · cited 3×
“Some applications of nasal CFD models include inhalation toxicology (Kimbell et al., 2001; Schroeter et al., 2008), nasal drug delivery (Kimbell et al., 2007; Inthavong et al., 2008), olfaction (Zhao et al., 2004), and nasal surgery (Garcia et al., 2010).”
BackgroundMethodKelly, J. T., Asgharian, B., Kimbell, J. S., & Wong, B. A. (2004) · Aerosol Science and Technology · doi:10.1080/027868290883360 · Cited by 294 · cited 28×
“In particular, the deposition data by Kelly et al. (2004b) has frequently been used for validation of CFD predictions (Shi et al., 2007; Inthavong et al., J Aerosol Sci. Author manuscript; available in PMC 2012 January 1.”
BackgroundMethodResultInfluentialSelf-citationCOMPUTATIONAL FLUID DYNAMICS SIMULATIONS OF INSPIRATORY AIRFLOW IN THE HUMAN NOSE AND NASOPHARYNX
Subramaniam, R. P., Richardson, R. B., Morgan, K. T., Kimbell, J. S., & Guilmette, R. A. (1998) · Inhalation Toxicology · doi:10.1080/089583798197772 · Cited by 269 · cited 7×
“For example, the geometry of the nasal replica cast used by Kelly et al. (2004b) was based on a CFD model that had been developed from digital tracings of MRI images (Subramaniam et al., 1998).”
BackgroundMethodInfluentialSelf-citationCharacterization of Nasal Spray Pumps and Deposition Pattern in a Replica of the Human Nasal Airway
Cheng, Y. S., Holmes, T. D., Gao, J., Guilmette, R. A., Li, S., Surakitbanharn, Y., & Rowlings, C. (2001) · Journal of Aerosol Medicine · doi:10.1089/08942680152484199 · Cited by 233 · cited 2×
“N IH -PA Author M anuscript N IH -PA Author M anuscript exploited by engineering spray devices that maximize deposition of aerosolized medications at target sites within the nasal cavity (O’Hagan and Rappouli, 2001; Cheng et al., 2001; Kimbell et al., 2007; Foo et al., 2007; Inthavong et al., 2008).”
BackgroundModeling of inertial particle transport and deposition in human nasal cavities with wall roughness
Shi, H., Kleinstreuer, C., & Zhang, Z. (2007) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2007.02.002 · Cited by 190 · cited 7×
“In particular, the deposition data by Kelly et al. (2004b) has frequently been used for validation of CFD predictions (Shi et al., 2007; Inthavong et al., J Aerosol Sci. Author manuscript; available in PMC 2012 January 1.”
BackgroundMethodResultInfluentialXi, J., & Longest, P. W. (2008) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2008.04.037 · Cited by 175 · cited 3×
“…on the same MRI dataset have been used by multiple investigators for in vitro (Guilmette et al., 1994; Swift, 1991; Kelly et al., 2004a, 2004b; Garcia et al., 2009) and in silico (Subramaniam et al., 1998; Schroeter et al., 2006, Shi et al., 2007, Xi and Longest, 2008) studies of nasal deposition.”
MethodResultKimbell, J. S., Segal, R. A., Asgharian, B., Wong, B. A., Schroeter, J. D., Southall, J. P., Dickens, C. J., Brace, G., & Miller, F. J. (2007) · Journal of Aerosol Medicine · doi:10.1089/jam.2006.0531 · Cited by 174 · cited 4×
“, 2008), nasal drug delivery (Kimbell et al., 2007; Inthavong et al., 2008), olfaction (Zhao et al.”
BackgroundInfluentialSelf-citation
Cited by
Guastella, A. J., Hickie, I. B., McGuinness, M. M., Otis, M., Woods, E. A., Disinger, H. M., Chan, H.-K., Chen, T. F., & Banati, R. B. (2013) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2012.11.019 · Cited by 357
In silico models of aerosol delivery to the respiratory tract — Development and applications
Longest, P. W., & Holbrook, L. T. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.05.009 · Cited by 233
“[149] recently showed that both surface roughness and model smoothness must be considered to successfully match in vitro results for inertial particle deposition in the nose.”
Metadata
- Authors
- Schroeter, J. D., Garcia, G. J. M., & Kimbell, J. S.
- Venue
- Journal of Aerosol Science
- Publisher
- Elsevier BV
- Published
- 2011-01
- Volume
- 42
- Issue
- 1
- Pages
- 52-63
- ISSN
- 0021-8502 (ISSN-L)
- OpenAlex
- W2104936628
- Cited by
- 160
- References
- 35
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of surface smoothness on inertial particle deposition in human nasal models. https://app.cochat.ai/papers/10.1016/j.jaerosci.2010.11.002
- The paper
- Schroeter, J. D., Garcia, G. J. M., & Kimbell, J. S. (2011). Effects of surface smoothness on inertial particle deposition in human nasal models. Journal of Aerosol Science. https://doi.org/10.1016/j.jaerosci.2010.11.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.