Improving mass accuracy of high performance liquid chromatography/electrospray ionization time-of-flight mass spectrometry of intact antibodies
The DOI matches its Crossref record.
Abstract
The glycosylation profile of intact antibody due to the galactose and fucose heterogeneity in the N-linked sugars was determined with instrument resolution of 5000 and 10,000. After deconvolution of electrospray ionization mass spectra to complete convergence, several extra peaks appeared in addition to the peaks observed in the original mass spectra. The artificial peaks were avoided if deconvolution was stopped after a smaller number of iterations. A standard antibody was used as an external calibrant to minimize mass measurement errors during long-period experiments. Precision of four consecutive LC/MS measurements of the same antibody was 10 ppm (+/-1.5 Da). By using this approach, the masses of 11 intact antibodies were measured. All antibodies containing N-terminal glutamines had a negative mass shift due to the formation of pyroglutamate (-17 Da). Although the pyroglutamate variant of intact antibody was not resolved from the unmodified variant, this modification led to a mass shift proportional to the percentage of N-terminal pyroglutamate. By accurately measuring the mass shift we were able to quantify the abundance of pyroglutamic acid on intact antibodies. Mass accuracy in measuring different antibodies was below 30 ppm (+/-4 Da). The accurate mass measurement can be an effective tool for monitoring chemical degradations in therapeutic antibodies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Mass spectrometry for structural characterization of therapeutic antibodies
Zhang, Z., Pan, H., & Chen, X. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20190 · Cited by 316
Huhn, C., Selman, M. H. J., Ruhaak, L. R., Deelder, A. M., & Wuhrer, M. (2009) · PROTEOMICS · doi:10.1002/pmic.200800715 · Cited by 301
Rehder, D. S., Chelius, D., McAuley, A., Dillon, T. M., Xiao, G., Crouse-Zeineddini, J., Vardanyan, L., Perico, N., Mukku, V., Brems, D. N., et al. (2008) · Biochemistry · doi:10.1021/bi7018223 · Cited by 110
Self-citationNaumann, L., Schlossbauer, P., Klingler, F., Hesse, F., Otte, K., & Neusüß, C. (2022) · Journal of Separation Science · doi:10.1002/jssc.202100865 · Cited by 18
Metadata
- Authors
- Gadgil, H. S., Pipes, G. D., Dillon, T. M., Treuheit, M. J., & Bondarenko, P. V.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-06-01
- Volume
- 17
- Issue
- 6
- Pages
- 867-872
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2011024907
- Cited by
- 76
- References
- 0
- FWCI
- 3.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improving mass accuracy of high performance liquid chromatography/electrospray ionization time-of-flight mass spectrometry of intact antibodies. https://app.cochat.ai/papers/10.1016/j.jasms.2006.02.023
- The paper
- Gadgil, H. S., Pipes, G. D., Dillon, T. M., Treuheit, M. J., & Bondarenko, P. V. (2006). Improving mass accuracy of high performance liquid chromatography/electrospray ionization time-of-flight mass spectrometry of intact antibodies. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/j.jasms.2006.02.023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.