The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Sublimation as a method of matrix application for mass spectrometric imaging
Open accessAbstract
Common organic matrix-assisted laser desorption/ionization (MALDI) matrices, 2,5-dihydroxybenzoic acid, 3,5-dimethoxy-4-hydroxycinnamic acid, and alpha-cyano-4-hydroxycinnamic acid, were found to undergo sublimation without decomposition under conditions of reduced pressure and elevated temperature. This solid to vapor-phase transition was exploited to apply MALDI matrix onto tissue samples over a broad surface in a solvent-free application for mass spectrometric imaging. Sublimation of matrix produced an even layer of small crystals across the sample plate. The deposition was readily controlled with time, temperature, and pressure settings and was highly reproducible from one sample to the next. Mass spectrometric images acquired from phospholipid standards robotically spotted onto a MALDI plate yielded a more intense, even signal with fewer sodium adducts when matrix was applied by sublimation relative to samples where matrix was deposited by an electrospray technique. MALDI matrix could be readily applied to tissue sections on glass slides and stainless steel MALDI plate inserts as long as good thermal contact was made with the condenser of the sublimation device. Sections of mouse brain were coated with matrix applied by sublimation and were imaged using a Q-q-TOF mass spectrometer to yield mass spectral images of very high quality. Image quality is likely enhanced by several features of this technique including the microcrystalline morphology of the deposited matrix, increased purity of deposited matrix, and evenness of deposition. This inexpensive method was reproducible and eliminated the potential for spreading of analytes arising from solvent deposition during matrix application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Mouse Brain in Stereotaxic Coordinates
Paxinos, G. (2001) · Cited by 13,417
Direct Molecular Analysis of Whole-Body Animal Tissue Sections by Imaging MALDI Mass Spectrometry
Khatib-Shahidi, S., Andersson, M., Herman, J. L., Gillespie, T. A., & Caprioli, R. M. (2006) · Analytical Chemistry · doi:10.1021/ac060788p · Cited by 505
Touboul, D., Kollmer, F., Niehuis, E., Brunelle, A., & Laprévote, O. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.06.005 · Cited by 364
Lechene, C., Hillion, F., McMahon, G., Benson, D., Kleinfeld, A. M., Kampf, J. P., Distel, D., Luyten, Y., Bonventre, J., Hentschel, D., et al. (2006) · Journal of Biology · doi:10.1186/jbiol42 · Cited by 346
Automated Acoustic Matrix Deposition for MALDI Sample Preparation
Aerni, H.-R., Cornett, D. S., & Caprioli, R. M. (2006) · Analytical Chemistry · doi:10.1021/ac051534r · Cited by 344
Mass Spectrometric Imaging of Lipids in Brain Tissue
Sjövall, P., Lausmaa, J., & Johansson, B. (2004) · Analytical Chemistry · doi:10.1021/ac049389p · Cited by 313
MALDI-MS imaging of features smaller than the size of the laser beam
Jurchen, J. C., Rubakhin, S. S., & Sweedler, J. V. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.06.006 · Cited by 285
Protein Profiling in Brain Tumors Using Mass Spectrometry
Schwartz, S. A., Weil, R. J., Johnson, M. D., Toms, S. A., & Caprioli, R. M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-0927-3 · Cited by 206
Altelaar, A. F. M., van Minnen, J., Jiménez, C. R., Heeren, R. M. A., & Piersma, S. R. (2005) · Analytical Chemistry · doi:10.1021/ac048329g · Cited by 182
Lipidomics: An analysis of cellular lipids by ESI-MS
Milne, S., Ivanova, P., Forrester, J., & Alex Brown, H. (2006) · Methods · doi:10.1016/j.ymeth.2006.05.014 · Cited by 172
Garrett, T. J., Prieto-Conaway, M. C., Kovtoun, V., Bui, H., Izgarian, N., Stafford, G., & Yost, R. A. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.09.019 · Cited by 160
Jackson, S. N., Wang, H. Y. J., & Woods, A. S. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.08.015 · Cited by 126
Introduction to Organic Laboratory Techniques: A Contemporary Approach
Pavia, D. L., Lampman, G. M., & Kriz, G. S. (1997) · Medical Entomology and Zoology · Cited by 109
Cited by
Norris, J. L., & Caprioli, R. M. (2013) · Chemical Reviews · doi:10.1021/cr3004295 · Cited by 696
Mass Spectrometric Imaging for Biomedical Tissue Analysis
Chughtai, K., & Heeren, R. M. A. (2010) · Chemical Reviews · doi:10.1021/cr100012c · Cited by 652
Kompauer, M., Heiles, S., & Spengler, B. (2017) · Nature Methods · doi:10.1038/nmeth.4071 · Cited by 600
Han, X., Yang, K., & Gross, R. W. (2012) · Mass Spectrometry Reviews · doi:10.1002/mas.20342 · Cited by 530
A concise review of mass spectrometry imaging
Amstalden van Hove, E. R., Smith, D. F., & Heeren, R. M. A. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.033 · Cited by 416
Metadata
- Authors
- Hankin, J. A., Barkley, R. M., & Murphy, R. C.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-09-01
- Volume
- 18
- Issue
- 9
- Pages
- 1646-1652
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2053190232
- Cited by
- 598
- References
- 13
- FWCI
- 11.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.