Top-down quantitation and characterization of SILAC-labeled proteins
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Stable isotope labeling by amino acids in cell culture (SILAC) has become a popular labeling strategy for peptide quantitation in proteomics experiments. If the SILAC technology could be extended to intact proteins, it would enable direct quantitation of their relative expression levels and of the degree of modification between different samples. Here we show through modeling and experiments that SILAC is suitable for intact protein quantitation and top-down characterization. When SILAC-labeling lysine and/or arginine, peaks of light and heavy SILAC-doublets do not interfere with peaks of different charge states at least between 10 and 200 kDa. Unlike chemical methods, SILAC ensures complete incorporation-all amino acids are labeled. The isotopic enrichment of commercially available SILAC amino acids of nominally 95% to 98% shifts the mass difference between light and heavy state but does not lead to appreciably broadened peaks. We expressed labeled and unlabeled Grb2, a 28 kDa signaling protein, and showed that the two forms can be quantified with an average standard deviation of 6%. We performed on-line top-down sequencing of both forms in a hybrid linear ion trap orbitrap instrument. The quantized mass offset between fragments provided information about the number of labeled residues in the fragments, thereby simplifying protein identification and characterization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Self-citationOng, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574 · cited 1×
“Our laboratory has previously described a metabolic labeling method called stable isotope labeling by amino acids in cell culture (SILAC, [3]).”
MethodSelf-citationMass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572 · cited 1×
“In recent years, the need for quantitative as opposed to qualitative proteomics experiments has become apparent, and a large number of different approaches have been developed, mainly based on incorporation of a “light” and “heavy” stable isotope tag [2].”
BackgroundSelf-citationZamdborg, L., LeDuc, R. D., Glowacz, K. J., Kim, Y.-B., Viswanathan, V., Spaulding, I. T., Early, B. P., Bluhm, E. J., Babai, S., & Kelleher, N. L. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm371 · Cited by 251
Cited by
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
“F or p er so na l u se o nl y. Table 2 Approaches in mass spectrometry proteomicsa Prerequisite Advantages Drawbacks Applications Front end Analysis Top down High mass accuracy instruments High sequence coverage Precursor ion charge state limitations Single-protein characterization Ion-exchange chromatography EST LTQ-…”
BackgroundMethodInfluentialOrbitrap mass spectrometry: Instrumentation, ion motion and applications
Perry, R. H., Cooks, R. G., & Noll, R. J. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20186 · Cited by 514
Michalski, A., Damoc, E., Lange, O., Denisov, E., Nolting, D., Müller, M., Viner, R., Schwartz, J., Remes, P., Belford, M., et al. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.013698 · Cited by 373
Self-citationQuantitative Proteomic Analysis of Histone Modifications
Huang, H., Lin, S., Garcia, B. A., & Zhao, Y. (2015) · Chemical Reviews · doi:10.1021/cr500491u · Cited by 370
Zhang, Z., Wu, S., Stenoien, D. L., & Paša-Tolić, L. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020216 · Cited by 323
Metadata
- Authors
- Waanders, L. F., Hanke, S., & Mann, M.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-11-01
- Volume
- 18
- Issue
- 11
- Pages
- 2058-2064
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2087382378
- Cited by
- 93
- References
- 4
- FWCI
- 3.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Top-down quantitation and characterization of SILAC-labeled proteins. https://app.cochat.ai/papers/10.1016/j.jasms.2007.09.001
- The paper
- Waanders, L. F., Hanke, S., & Mann, M. (2007). Top-down quantitation and characterization of SILAC-labeled proteins. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/j.jasms.2007.09.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.