Although only a few years old, the combination of a linear ion trap with an Orbitrap analyzer has become one of the standard mass spectrometers to characterize proteins and proteomes. Here we describe a novel version of this instrument family, the Orbitrap Elite, which is improved in three main areas. The ion transfer optics has an ion path that blocks the line of sight to achieve more robust operation. The tandem MS acquisition speed of the dual cell linear ion trap now exceeds 12 Hz. Most importantly, the resolving power of the Orbitrap analyzer has been increased twofold for the same transient length by employing a compact, high-field Orbitrap analyzer that almost doubles the observed frequencies. An enhanced Fourier Transform algorithm-incorporating phase information-further doubles the resolving power to 240,000 at m/z 400 for a 768 ms transient. For top-down experiments, we combine a survey scan with a selected ion monitoring scan of the charge state of the protein to be fragmented and with several HCD microscans. Despite the 120,000 resolving power for SIM and HCD scans, the total cycle time is within several seconds and therefore suitable for liquid chromatography tandem MS. For bottom-up proteomics, we combined survey scans at 240,000 resolving power with data-dependent collision-induced dissociation of the 20 most abundant precursors in a total cycle time of 2.5 s-increasing protein identifications in complex mixtures by about 30%. The speed of the Orbitrap Elite furthermore allows scan modes in which complementary dissociation mechanisms are routinely obtained of all fragmented peptides.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1074/mcp.o111.013698

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. [31]Wouters E. R. Splendore M. Mullen C. Schwartz J. C. Senko M. Dunyach J. J. (2009) Implementation of a progressively spaced stacked ring ion guide on a linear ion trap mass spectrometer. 57th Amer. Soc. Mass Spectrom. Annual Conf. on Mass Spectrometry & Allied Topics, Philadelphia, PA, May 31–June 5 (2009)

Cited by

Sorted by citations

Authors
Michalski, A., Damoc, E., Lange, O., Denisov, E., Nolting, D., Müller, M., Viner, R., Schwartz, J., Remes, P., Belford, M., Dunyach, J.-J., Cox, J., Horning, S., Mann, M., & Makarov, A.
Affiliations
  • Max Planck Institute of Biochemistry (DE)
  • Thermo Fisher Scientific (Germany) (DE)
  • Thermo Fisher Scientific (United States) (US)
Corresponding author
Mann, Matthias
Venue
Molecular & Cellular Proteomics
Publisher
Elsevier BV
Published
2012-03
Volume
11
Issue
3
Pages
O111.013698
ISSN
1535-9476 (ISSN-L)
OpenAlex
W2066928228
Cited by
373
References
41
Citations by year
2026: 7 · 2025: 11 · 2024: 17 · 2023: 15 · 2022: 16 · 2021: 22 · 2020: 21 · 2019: 24 · 2018: 19 · 2017: 32 · 2016: 20 · 2015: 35 · 2014: 41 · 2013: 62 · 2012: 29
FWCI
19.13
Type
journal article
Language
en
Open access
Locations
  • Molecular & Cellular Proteomics (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • MPG.PuRe (Max Planck Society) (submittedVersion, other-oa)
  • Max Planck Institute for Plasma Physics (submittedVersion)
Funders
  • Northwestern University
  • European Commission (201648)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
Keywords
linear ion trap, top-down proteomics, peptide fragmentation, resolving power, Fourier transform algorithm, shotgun proteomics
MeSH terms
Chromatography, Liquid, HeLa Cells, Humans, Peptide Fragments, Proteome, Proteomics, Tandem Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review